Brand: KRACHT
KRACHT AS 8 I 24 ZM / F Cylinder Stroke Measuring Unit
Description
KRACHT AS 8 I 24 ZM / F turns oil flow into cylinder position
KRACHT AS 8 I 24 ZM / F is the cylinder stroke version of the AS 8 panel instrument. Fed by a KRACHT volume counter in the line to the cylinder, it integrates the oil that flows into the cylinder and shows the result as position in millimetres, so that the movement of a hydraulic drive can be measured without a linear transducer on the cylinder.
The code says AS 8, I (current output of up to 20 mA), 24 (24 VDC supply), ZM (cylinder stroke measurement) and F (membrane keyboard in front). This page quotes the KRACHT Electronics datasheet of June 2021, and Seven Star LLC is an independent supplier serving Oman and the GCC, not affiliated with the manufacturer.
How indirect stroke measurement works with AS 8 I 24 ZM / F
A volume counter in the control line produces pulses in proportion to the oil volume and its direction. The unit converts the pulses into flow, volume, path and velocity. The directional valve decides whether the pulses add or subtract, so the display runs up when the cylinder extends and back when it retracts.
Leakage at the end positions would normally cause errors, because a few drops pass the piston while the cylinder is at rest. The ZM program therefore has a programmable trap frequency: pulses are not processed until the flow exceeds that frequency. A reset input sets the position to zero, for example at the retracted end stop.
Example given in the datasheet: a cylinder position of 200.0 mm shown on the display, with two relay contacts for limit signalling.
Technical data of AS 8 I 24 ZM / F
| Parameter | Value |
|---|---|
| Type code | AS 8 I 24 ZM / F |
| Output signal | Current, 0 to 20 mA / 4 to 20 mA / plus-minus 20 mA (analogue output, apparent resistance up to 250 ohm) |
| Supply voltage | 24 VDC |
| Program version | ZM cylinder stroke measurement |
| Keyboard | Membrane keyboard (F) |
| Display | 7-segment LED, 13.2 mm, red, 0.000 to 9999 with floating point |
| Power consumption | approx. 3.5 W |
| Sensor supply | 24 VDC plus/minus 20 percent, 50 mA |
| Relays | 2 relay contacts, 24 V / 1 A |
| Digital inputs | 2, input amplitude min up to 9 V, max from 12 V |
| Counter input frequency | 1 Hz to 2500 Hz |
| Front frame | 96 x 48 mm (DIN 43700) |
| Installation depth | approx. 122 mm with connector strip |
| Panel cut-out | 92 x 45 mm |
| Protection | IP 54 with correct panel assembly |
| Operating temperature | 0 to 60 C |
| Weight | approx. 0.4 kg |
How AS 8 I 24 ZM / F differs from other AS 8 versions
All AS 8 versions share the same housing, display and inputs; what differs is the program inside and the way the front panel is operated. The standard version shows flow or volume, the RP program controls flow or speed, DOS doses a preset quantity, and ZM converts pulses to stroke. D2F and PUR need a second volume counter, whereas ZM uses one counter plus a direction signal.
Compared with the DOS version, the ZM has no start input or six-quantity memory. Compared with the RP version, it does not drive a control valve; it only displays and signals position through two relays and the analogue output.
Applications of AS 8 I 24 ZM / F in plants and workshops
Presses, test cylinders, tilting platforms, hydraulic gates and lifting equipment are typical. Where a linear sensor cannot be installed because of space, temperature or cost, the volume counter in the oil line provides the information instead. For Gulf maintenance teams, a stroke display can be added to existing hydraulic equipment without drilling into the cylinder.
In engineering workshops the unit is used on test rigs that must prove a stroke time and travel against a specification.
Selection and wiring notes
Choose the supply voltage when ordering: the type key lists 230 V, 120 V, 24 VDC and 12 VDC, and this code is the 24 VDC version with a current output. The integrated 24 V encoder supply of 50 mA powers the volume counter directly, so no separate supply is needed for the sensor.
Connections are on a 15-pin screw terminal block. Two digital inputs and two relays are available. An RS 232 interface can be ordered as an alternative output, and the analogue output can be configured for 4 to 20 mA. Keep the cable from the volume counter shielded.
Installing and commissioning AS 8 I 24 ZM / F
Cut a panel opening of 92 x 45 mm, push the 96 x 48 mm front frame in and leave about 122 mm of depth behind the panel. Commission by moving the cylinder to its reference end, resetting the display, then running to the opposite end and comparing the displayed stroke to the physical stroke; adjust the pulse factor until the two match.
Care
The instrument is maintenance free; periodically verify the stroke reading against a measured length and clean the front panel. Because stroke is derived from oil volume, any internal leakage past the piston gradually shifts the zero, which is why you re-zero at an end stop.
Ordering and related units
Quote AS 8 I 24 ZM / F with quantity. Related KRACHT display and control electronics in this series: AS 8 U 230 DOS / F, AS 8 I 24 RP, AS 8 U 24 D2F / F, AS 8 U 230 PUR / F, SD 1 R 24 and ASR 30.
Documents and quotation
The datasheet is attached. Send an RFQ for AS 8 I 24 ZM / F with quantity to Seven Star LLC.
Ordering Checklist for the KRACHT AS 8 I 24 ZM / F
Before you ask for a quotation for the KRACHT AS 8 I 24 ZM / F, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the flow computers already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.
Installation and Commissioning Planning
Planning ahead shortens downtime when a KRACHT AS 8 I 24 ZM / F goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the KRACHT equipment can be planned around it.
Other Models in the Kracht As8 Electronics Range
Seven Star LLC supplies models from the Kracht As8 Electronics range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT AS 8 I 24 ZM / F Cylinder Stroke Measuring Unit | Flow Computers | You are viewing this model |
| KRACHT AS 8 U 230 DOS / F Dosing Controller 230 V | Flow Computers | View details |
| KRACHT AS 8 I 24 RP Flow and Speed Controller 24 VDC | Flow Computers | View details |
| KRACHT AS 8 U 24 D2F / F Flow Difference Display | Flow Computers | View details |
| KRACHT AS 8 U 230 PUR / F Mixing Ratio Controller | Flow Computers | View details |
| KRACHT SD 1 R 24 Plug-On Flow Display Square-Wave Output | Flow Computers | View details |
Datasheets & Documents
- Datasheet KRACHT AS 8 I 24 ZM / F Cylinder Stroke Measuring Unit Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT AS 8 I 24 ZM / F Cylinder Stroke Measuring
Answers from our engineering team on installation, compatibility and integration.
01What does the ZM program of KRACHT AS 8 I 24 ZM / F do?
It computes cylinder position and velocity from volume counter pulses and flow direction, shown for example as 200.0 mm on the display.
02What prevents end-position leakage errors in AS 8 I 24 ZM / F?
A programmable trap frequency: pulses are ignored until the flow exceeds the trap frequency.
03What supply does AS 8 I 24 ZM / F need?
24 VDC, which is the supply variant coded 24, and it provides a 24 V encoder supply of 50 mA for the volume counter.
04What outputs does AS 8 I 24 ZM / F offer?
Two relay contacts (24 V / 1 A) and an analogue output; the current-output code I gives 0 to 20 mA, 4 to 20 mA or plus-minus 20 mA.
05What are the panel dimensions of AS 8 I 24 ZM / F?
Front frame 96 x 48 mm to DIN 43700, panel cut-out 92 x 45 mm and installation depth about 122 mm.