Description
7955 flow computer specification
• Pulse integrity to IP 252/76, API Ch 5.5 Level A
• 5 Serial ports & 1 Ethernet port
• High resolution 20 bit A/D converter for analog inputs
• 4 meter run (stream) and proving capability
• Hot duty standby for multi-stream applications
available as standard
Overview
The Emerson 7955 Flow Computer is a proven, panel-mount fiscal flow computer engineered for custody transfer, fiscal metering, proving, and pipeline measurement across upstream, midstream, and downstream operations. It combines high-accuracy calculations with resilient pulse handling, secure logging, and modern communications, delivering defensible totals and smooth integration with SCADA/DCS/PLC systems. For teams standardizing measurement across multiple assets, the 7955 offers a reliable, multi-stream platform that’s field-friendly and audit-ready.
⸻
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Emerson |
| Model | 7955 |
| Product Type | Panel-mount fiscal flow computer |
| Meter Runs | Up to 4 meter runs (streams) with proving capability |
| Analog Input Resolution | 20-bit A/D converter |
| Pulse Integrity | IP 252/76, API Ch 5.5 Level A |
| Communication Ports | 5 serial ports (RS-232/422/485) and 1 Ethernet port |
| Protocol | Modbus |
| Redundancy | Hot duty standby for multi-stream applications |
| Reports | Hourly, daily and monthly |
| Compatible Meters | Turbine, PD, ultrasonic, Coriolis, differential pressure/orifice |
Key Features
• Multi-stream capability: supervise up to 4 meter runs, suitable for single- and multi-meter skids, allocation lines, and terminal duties
• High-fidelity measurement: 20-bit A/D resolution on analog inputs for stable, repeatable results during proving and batch transitions
• Pulse integrity: designed for turbine/PD/other pulsed meters with industry-recognized pulse handling so fiscal totals remain defensible
• Industrial communications: Ethernet plus multiple serial ports (RS-232/422/485); Modbus-friendly and SCADA/DCS/PLC ready
• Secure operations & logging: granular user roles, alarms/events, and periodic hourly/daily/monthly reports streamline reconciliation and audits
• Proving & reporting: supports meter proving workflows and structured reports that accelerate third-party verification
• Integration without friction: straightforward handoff to historians, data lakes, and enterprise reporting via standard protocols
⸻
Applications
• Custody-transfer metering skids and LACT units
• Pipeline measurement, allocation, and balancing
• Gas/liquid fiscal metering in terminals and tank farms
• Meter proving (bidirectional or compact provers) with repeatable results
• Batch loading and batch reporting
• Wet-gas / condensate scenarios demanding resilient algorithms and clean audit trails
⸻
Technical Snapshot
• Meter runs: up to 4 runs (multi-stream) for flexible deployment across lines and products
• I/O & comms: Ethernet + multiple serial ports (RS-232/422/485) for brownfield/greenfield connectivity
• Measurement chain: 20-bit A/D for analog inputs; robust pulse acquisition aligned with industry practice for turbine/PD/other pulsed elements
• Data integrity: alarm/event logs with scheduled reports (hourly/daily/monthly) for regulatory and contractual compliance
• SCADA/DCS/PLC integration: Modbus-friendly design simplifies commissioning and lifecycle maintenance
⸻
Why Choose Emerson 7955?
• Fiscal accuracy, proven in the field—built to keep uncertainty budgets tight and audits smooth
• Scalable & maintainable—multi-stream capability and practical comms reduce project risk and integration time
• Lower lifecycle cost—faster commissioning, consistent reports, and fewer site visits
• Enterprise-ready—clean handoff to historians and corporate reporting
⸻
Helpful Resource
New to flow computers or training stakeholders? Read our primer: What is a Flow Computer?
⸻
Request a Quote for Emerson 7955 Flow Computer
Ready to secure more accurate, auditable totals? Request a Quote now to receive the official Emerson 7955 datasheet, recommended configuration (meter runs, reports, protocols), and lead time tailored to your application.
Specifying a 7955 for a Metering System
A flow computer is configured around the metering system it serves, so the specification should begin with the skid design rather than the hardware. Define the number of meter runs and whether a prover is included, the meter types and their outputs, the fluid (crude, refined products, condensate or gas) and the calculation standards required by the sales contract or regulator. From there, list every transmitter input, densitometer and sampler signal so the I/O count can be checked against the available capacity, with spare channels kept for future changes.
- Number of streams and prover arrangement
- Meter type and pulse or analog output
- Fluid, calculation standards and units
- Host systems and the protocol each will use
- Report formats required by the buyer, seller or authority
For a replacement or spare unit, record the model and option codes from the existing flow computer and save a copy of its configuration before any hardware change.
Commissioning and Acceptance
Commissioning a fiscal flow computer is a documented process, normally witnessed by the parties to the custody transfer. Typical steps include checking every input against a calibrated source, verifying calculations with independent test values, confirming pulse fidelity alarms, running proving sequences and approving the report layouts. Configuration settings should be locked down and the security levels assigned before the system goes into fiscal service, so every later change is traceable.
Maintenance and Troubleshooting
- Review the alarm and event logs routinely, not only when totals are disputed.
- Investigate pulse integrity alarms promptly, as they often point to cabling, grounding or preamplifier issues at the meter.
- Verify transmitter inputs at the intervals set by the metering procedures.
- Keep dated configuration backups and record every change for audit.
- Check hot standby changeover during planned tests where a duty/standby pair is used.
Custody Transfer Metering in Oman and the GCC
Oman’s crude export, pipeline, terminal and product loading facilities, like those across the Gulf, depend on accurate fiscal measurement because small errors translate into large commercial volumes. Flow computers such as the 7955 sit at the centre of these systems, and keeping a compatible spare on hand shortens recovery time if a unit fails on a busy metering station.
Sourcing Through Seven Star LLC
Seven Star LLC supplies flow computers and metering spares to operators and integrators across Oman and the GCC. Send us your existing model details or skid requirements, and we will confirm a suitable configuration and lead time.
Related Products
- OMNI 4000/7000 Series
- Elster® enCore ZM1 Flow Computers
- NI cRIO-9053 CompactRIO Real-Time Controller
- OMNI 6000 Flow Computer
- Fluidwell F126-EG Field Mount Flow Computer
- FloBoss S600+ Flow Computer | Emerson Custody Transfer & Fiscal Measurement
See also: ROC809 Remote Operations Controller; FloBoss 107 Flow Manager.
Reviews (0)
How would you rate this product? Cancel reply
About brand
Emerson is the American automation group behind well-known brands such as Rosemount, Fisher, Micro Motion, DeltaV and the ROC and FloBoss flow computers. It started in St. Louis, Missouri, in 1890, when the Scottish-born brothers Charles and Alexander Meston set up a company to make electric motors and fans, financed by the judge and former Union officer John Wesley Emerson. Emerson Electric Co. is headquartered in St. Louis and listed on the New York Stock Exchange.
Seven Star LLC, an independent supplier, sources these Emerson products and their spare parts for users in Oman and the GCC.
Emerson company profile
| Founded | 1890, St. Louis, Missouri, USA, as a maker of electric motors and fans |
|---|---|
| Founders | Charles and Alexander Meston, with financial backing from John Wesley Emerson |
| Headquarters | St. Louis, Missouri, USA |
| Ownership | Emerson Electric Co., public company (NYSE: EMR) |
| Key acquisitions | Rosemount (1976) and Fisher Controls (1992) |
| Product families in our range | ROC800 and FloBoss flow computers and RTUs, wireless gateways, Rosemount transmitters and analysers, Fisher control valves (listed on their own brand pages) |
Milestones
- 1890: The Meston brothers start making electric motors and fans in St. Louis.
- 1892: Herbert L. Parker buys Judge Emerson's controlling interest.
- 1976: Emerson acquires Rosemount, its entry into process measurement.
- 1992: Fisher Controls is acquired.
Emerson product families on this page
The measurement and control group includes the ROC809 and the expandable ROC827 Remote Operations Controllers, the ROC800L for liquid measurement and the FloBoss 107 Flow Manager. Flow metering is represented by Micro Motion ELITE CMF Coriolis sensors and the 5700 transmitter. For valves there is the DVC6200 digital valve controller, plus solenoid valves and a safety relief valve. DeltaV hardware includes the PK Controller and DeltaV SIS components. Field tools are the AMS Trex Device Communicator and the earlier 475 Field Communicator, and wireless networks use the 1410S gateway with the 781S smart antenna. The cooling items are Copeland scroll and semi-hermetic compressors, which were sold for many years under the Emerson name.
Where Emerson equipment is used
ROC and FloBoss units calculate and log gas and liquid flow at production sites and custody transfer points. Micro Motion meters measure mass flow and density in loading, blending and fiscal metering. DVC6200 controllers position control valves and report valve diagnostics, and DeltaV runs process units in refineries, chemical plants and utilities. Copeland compressors serve air conditioning and refrigeration plants.
Emerson products we list
Ordering Emerson parts: what we need
Send the full model string and serial number from the nameplate. For ROC800 units list the I/O and communication modules fitted and the application, gas or liquid. For Coriolis meters give both the sensor and the transmitter model. For DeltaV parts quote the 12P or KJ part number, and for compressors the complete model number with voltage code.
Facts checked against Emerson's published company history, October 2026.
FAQ
Questions about the Emerson 7955 Flow Computer
Answers from our engineering team on installation, compatibility and integration.
01How many meter runs does the 7955 support?
Up to 4 runs (multi-stream), suitable for mixed lines and allocation.
02What communications are available?
Ethernet plus multiple serial ports (RS-232/422/485); straightforward Modbus integration to SCADA/DCS/PLC.
03Is it suitable for proving and audits?
Yes—high-fidelity measurement (20-bit A/D), robust pulse handling, and structured hourly/daily/monthly reports support proving and third-party audits.
04Which meter types are supported?
Compatible with turbine, PD, ultrasonic, Coriolis, and differential pressure/orifice installations.
05How do I request a quotation for Emerson 7955 Flow Computer?
Send the model number, required quantity and delivery location through the quote request form or by email to Seven Star LLC. The sales team replies with availability, lead time and commercial terms for your Oman or GCC project.