Brand: Endress+Hauser (E & H)
Endress+Hauser CLA140 Dipfit Flanged Immersion Assembly
Description
CLA140 Dipfit: flanged immersion holder for conductivity sensors in harsh service
Endress+Hauser CLA140 is a Dipfit immersion assembly with a flange connection, intended for very demanding processes. The sensor sits in a holder with bayonet lock, so it can be installed or pulled without fighting a screw thread, and sealing remains reliable in media with solid particles. A breathable GORE-TEX filter in the head reduces condensation. The listed duties include chemical production (synthetic materials, dyes, pesticides, fertilisers), oil and water separation, condensate treatment, power station cooling water and flue gas cleaning, and metal extraction.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The sensor is ordered separately; the assembly ships without it.
CLA140 specifications
| Parameter | Value |
|---|---|
| Version PVDF process temperature | 0 to 120 degrees C |
| PVDF process pressure | Up to 6 bar absolute |
| Stainless steel temperature | Minus 15 to 150 degrees C; minus 15 to 140 degrees C with EPDM |
| Stainless steel pressure | Up to 10 bar absolute |
| Immersion depth | 500, 1000, 1500, 2000 or 2500 mm |
| Process connection | None, DN 80 PN 16, ANSI 3 inch 150 lbs or JIS 10K 80A |
| Flange bolting | M16; 8 holes on DN 80, 4 holes on ANSI and JIS |
| Sensor mounting slot | 1 x G 3/4 |
| Cable glands | 1 x Pg 13.5 and 2 x dummy plug Pg 16 |
| Wetted materials | Immersion tube and sensor holder PVDF or 1.4404 (316L); O-rings EPDM, Viton, Chemraz or Fluoraz |
| Dry parts | Head PP-GF 20; lap joint flange UP-GF or 1.4404; installation aids 1.4301 |
| Ambient and storage | Minus 10 to 70 degrees C |
| Protection | IP65 |
| Weight | PVDF 2.5 to 3.0 kg; stainless 8.0 to 12.0 kg |
| PED | Good engineering practice per Article 4(3) of Directive 2014/68/EU |
Bayonet holder and installation aids
The stainless steel version includes screw-in lifting eyes made of 1.4301 as installation aids, which matters for a 12 kg assembly at 2.5 m. The wrench grip is AF55. On the PVDF version a lap-joint flange simplifies bolting to a nozzle. Because the immersion tube and sensor holder are made of the same material as the wetted tube, a single wetted-material choice covers the whole assembly.
How CLA140 differs from other Dipfit and Flexdip assemblies
CPA140 is the Dipfit sibling for pH and ORP; CLA140 is the conductivity version with a G 3/4 mounting slot. The plastic CPA111 and CLA111 are open-vessel assemblies, and Flexdip CYA112 is a non-pressurised modular tube for basins. CLA140, by contrast, is flanged, handles up to 10 bar in stainless steel and up to 150 degrees C, and offers depths to 2500 mm. Between the two CLA140 versions the PVDF one is lighter and cheaper in corrosion, while stainless covers higher temperature and pressure.
Use of CLA140 in Gulf plants
Cooling water monitoring in power stations, condensate polishing, oil and water separation in refinery effluent and flue gas scrubbers are all listed by the maker, and they are common across Oman and the GCC. Fit an Indumax CLS50D inductive sensor to read conductivity in the harsh liquor, and connect it to a Liquiline CM442 transmitter; an extension cable such as CYK11 is optional.
Choosing between the PVDF and stainless CLA140
The PVDF version suits cooling water, condensate and most chemical liquors up to 120 degrees C and 6 bar absolute, and its weight of 2.5 to 3.0 kg makes it easy to handle on a platform. The stainless steel 1.4404 version reaches 150 degrees C (140 with EPDM seals), 10 bar absolute and an 8 to 12 kg weight, so it is the choice for flue gas cleaning, hot condensate and high-pressure vessels. Remember that the flange on the PVDF version is a loose lap-joint type of UP-GF or stainless, while the stainless version has a fixed flange with lifting eyes.
Flange dimensions differ slightly: DN 80 PN 16 uses eight M16 bolts, while ANSI 3 inch 150 lbs and JIS 10K 80A use four M16 bolts each. Check these against the mating nozzle before ordering.
Installation and care
- Check the immersion depth in the configurator so the sensor sits in representative flow.
- Use only a gasket and bolt kit suited to the flange standard ordered.
- Avoid condensation by keeping the GORE-TEX filter clean and unblocked.
- The bayonet lock lets you withdraw the sensor holder for cleaning without removing the assembly from the nozzle.
- Select the O-ring material for the process chemistry: EPDM, Viton, Chemraz or Fluoraz are listed.
CLA140 questions answered briefly
What sensors does Endress+Hauser CLA140 carry? The datasheet pairs it with conductivity sensors such as the inductive Indumax CLS50D and shows a Liquiline CM442 transmitter; the sensor is not included in the assembly delivery.
What are the temperature and pressure limits of CLA140? The PVDF version runs 0 to 120 degrees C at up to 6 bar abs; the stainless steel version runs minus 15 to 150 degrees C (140 with EPDM) at up to 10 bar abs.
Which immersion depths can CLA140 have? 500, 1000, 1500, 2000 or 2500 mm, set when the assembly is configured.
What flange options does CLA140 offer? DN 80 PN 16, ANSI 3 inch 150 lbs and JIS 10K 80A, or no flange at all, depending on version.
What is the weight of the CLA140? The PVDF version weighs 2.5 to 3.0 kg and the stainless steel version 8.0 to 12.0 kg, depending on immersion depth.
Documents and quotation
The datasheet for CLA140 is attached to this page. For a quotation send an RFQ with CLA140, the material (PVDF or stainless), flange standard, immersion depth and quantity, and let us know which conductivity sensor you will fit.
What to Include in Your Endress+Hauser CLA140 Enquiry
An accurate quotation for the Endress+Hauser CLA140 depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing instrument valves & fittings and reply with availability and a realistic delivery estimate.
Spares and Lifecycle Considerations
For critical service, many plants hold one Endress+Hauser CLA140 as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical instrument valves & fittings units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.
Datasheets & Documents
- Datasheet Endress+Hauser CLA140 Dipfit Flanged Immersion Assembly Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser CLA140 Dipfit Flanged Immersion
Answers from our engineering team on installation, compatibility and integration.
01What sensors does Endress+Hauser CLA140 carry?
The datasheet pairs it with conductivity sensors such as the inductive Indumax CLS50D and shows a Liquiline CM442 transmitter; the sensor is not included in the assembly delivery.
02What are the temperature and pressure limits of CLA140?
The PVDF version runs 0 to 120 degrees C at up to 6 bar abs; the stainless steel version runs minus 15 to 150 degrees C (140 with EPDM) at up to 10 bar abs.
03Which immersion depths can CLA140 have?
500, 1000, 1500, 2000 or 2500 mm, set when the assembly is configured.
04What flange options does CLA140 offer?
DN 80 PN 16, ANSI 3 inch 150 lbs and JIS 10K 80A, or no flange at all, depending on version.
05What is the weight of the CLA140?
The PVDF version weighs 2.5 to 3.0 kg and the stainless steel version 8.0 to 12.0 kg, depending on immersion depth.


















Reviews