- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Beamex
Beamex 9405050 RPRT-420-230A 90 Degree Reference Sensor
Description
Overview of Beamex RPRT-420-230A 90 degree reference sensor Beamex 9405050
The Beamex RPRT-420-230A (Beamex 9405050) is a 90 degree angled reference platinum resistance sensor with a calibrated range of minus 45 to 420 degrees C. The diameter is 6.35 mm and the length is 230 mm before the angle.
Each sensor is delivered with an accredited calibration certificate that includes sensor-specific ITS-90 and CvD correction coefficients, which are also stored in the sensor memory.
This page describes Beamex RPRT-420-230A 90 degree reference sensor for buyers who need the exact part number Beamex 9405050. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the data below is taken from the manufacturer published product pages and brochures.
Key features of 9405050
- Order code: 9405050.
- Calibrated range: -45 to 420 degrees C (-49 to 788 degrees F).
- Sensor diameter: 6.35 mm (1/4 in).
- Length before angle: 230 mm (9 in), 90 degree angled.
- Cable: 1.8 m (6 ft) teflon cable.
- Connector: Smart 6-pin Lemo, MC6 family R2.
- Calibration points: -45, -20, 0, 70, 232 and 420 degrees C.
Technical specifications for 9405050
| Order code | 9405050 |
|---|---|
| Calibrated range | -45 to 420 degrees C (-49 to 788 degrees F) |
| Sensor diameter | 6.35 mm (1/4 in) |
| Length before angle | 230 mm (9 in), 90 degree angled |
| Cable | 1.8 m (6 ft) teflon cable |
| Connector | Smart 6-pin Lemo, MC6 family R2 |
| Calibration points | -45, -20, 0, 70, 232 and 420 degrees C |
All values above come from the manufacturer documentation and may change with later revisions. Please quote 9405050 when you need the matching datasheet or a confirmation of the current revision.
Typical applications in Oman and the GCC
Reference sensors are the link between a dry block or bath and the traceable result. Calibration laboratories and instrument workshops in the GCC use them to check temperature transmitters, thermocouples and RTDs from refineries, power stations, desalination plants and food and beverage lines.
Using a calibrated reference with stored coefficients shortens the setup because the calibrator can read the sensor identity and correction data automatically.
The part is relevant wherever the related calibration equipment is used: oil and gas, utilities, water, process manufacturing and calibration service providers in Oman and the wider GCC.
Equipment used in Oman and the wider GCC faces high ambient temperatures, dust and coastal humidity. Keep instruments and accessories out of direct sun, avoid leaving them in closed vehicles, and allow cold equipment to acclimatise before use when moving from an air-conditioned room to an outdoor unit. Cap connectors and threads when they are not in use so that sand and moisture stay out.
Selection and compatibility notes for 9405050
The angled shape is suitable for the hard case 8081930, which is built for the 90 degree RPRT versions. The sensor must always be used with its certificate coefficients. The straight version is RPRT-420-300 (9405000).
Before ordering 9405050, confirm the model and, where relevant, the serial number or option code of the instrument it will serve. Confirm voltage, plug type, thread type or pressure rating as applicable, and check the manufacturer documentation for the firmware or hardware revision of the equipment.
If an item looks similar but carries a different part number, do not assume interchangeability. A short note of the calibrator model and application lets us confirm the match for 9405050 before it is supplied.
Installation and commissioning of 9405050
Insert the sensor fully into the block or bath, with the sensing part well below the surface and level with the sensors under test. Connect the connector to the matching port of the calibrator, let the reading settle, and check that the coefficients are recognised.
Handle the sensor gently. Avoid bending the stem, avoid thermal shock and keep the cable away from hot surfaces.
Maintenance and care
Return the sensor to its case after use. Keep it clean and dry and never use it beyond its calibrated range. Recalibrate at the interval required by your quality system, and use the coefficients from the newest certificate with 9405050.
Check the stability of the sensor in an ice point from time to time to detect drift or damage.
Calibration is only as useful as its records. Keep a log of serial numbers, certificate dates, replacement parts and any faults, and store the manufacturer documents with the equipment. This makes audits easier, helps predict when spares will be needed, and shortens the time needed to prepare a purchase request when a part has to be replaced at short notice.
Related products and ordering notes for 9405050
Related items are the dry block, the calibrator, the sensor transport case and a hard case. Please state the required range and connection when asking for a quotation.
Hard-to-find and discontinued spare parts are a daily topic for maintenance planners in oil, gas, power and water facilities. When a plant standardises on one calibrator family, a small stock of the exact spares is far cheaper than a day of lost production, and an early enquiry gives the supplier time to confirm availability and shipping options to Oman and neighbouring countries.
Please note that Seven Star LLC prepares each quotation for 9405050 against the exact part number, so a request that quotes the number and the quantity is answered faster than a general description.
The part number 9405050 should be quoted exactly as printed in this page, because accessories and spares with similar descriptions often differ by one digit.
Frequently asked questions about 9405050
- What shape is 9405050? A 90 degree angled sensor, 230 mm before the angle.
- What range is calibrated? Minus 45 to 420 degrees C, according to the manufacturer documentation for 9405050.
- Which case fits? The hard case 8081930 for MC6 and RPRT, according to the manufacturer documentation for 9405050.
- Are coefficients required? Yes, the sensor must always be used with them.
- Which port does it use? The R2 port of the MC6 family, according to the manufacturer documentation for 9405050.
Documents and quotation
The official Beamex RPRT reference temperature sensor brochure is attached to this page as a PDF. It gives the specifications of the RPRT reference sensors, including the RPRT-420-230A angled model. Share order code 9405050 together with your calibrator model and we will confirm the exact part in a written quotation.
Datasheets & Documents
- Datasheet Beamex RPRT Reference Sensor Brochure (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 9405050 RPRT-420-230A 90 Degree Reference
Answers from our engineering team on installation, compatibility and integration.
01What shape is 9405050?
A 90 degree angled sensor, 230 mm before the angle.
02What range is calibrated?
Minus 45 to 420 degrees C, according to the manufacturer documentation for 9405050.
03Which case fits?
The hard case 8081930 for MC6 and RPRT, according to the manufacturer documentation for 9405050.
04Are coefficients required?
Yes, the sensor must always be used with them.
05Which port does it use?
The R2 port of the MC6 family, according to the manufacturer documentation for 9405050.


















Reviews
There are no reviews yet.