Brand:

KRACHT AS 8 I 24 RP Flow and Speed Controller 24 VDC

Description

A compact flow controller: AS 8 I 24 RP

KRACHT AS 8 I 24 RP is the RP version of the AS 8, meaning flow and speed control. You set the target value on the unit, a volume counter or rotary encoder reports the actual value as square-wave pulses, and the instrument adjusts its output to keep the two equal.

The code reads AS 8, I (current output, plus-minus 20 mA, 0 to 20 mA or 4 to 20 mA), 24 (24 VDC supply) and RP. There is no keyboard letter at the end, so operation is through the three buttons behind the front panel.

Technical specification of AS 8 I 24 RP

Parameter Value
Type code AS 8 I 24 RP
Output signal Current, plus-minus 20 mA / 0 to 20 mA / 4 to 20 mA (apparent resistance up to 250 ohm, 10 bit)
Supply voltage 24 VDC
Program version RP flow and speed control
Keyboard Three keys behind the front panel
Display 7-segment LED, 13.2 mm, red, 0.000 to 9999 with floating point
Power consumption approx. 3.5 W
Sensor supply 24 VDC plus/minus 20 percent, 50 mA
Relays 2 relay contacts, 24 V / 1 A
Digital inputs 2, input amplitude min up to 9 V, max from 12 V
Counter input frequency 1 Hz to 2500 Hz
Front frame 96 x 48 mm (DIN 43700)
Installation depth approx. 122 mm with connector strip
Panel cut-out 92 x 45 mm
Protection IP 54 with correct panel assembly
Operating temperature 0 to 60 C
Weight approx. 0.4 kg

Two control tasks of AS 8 I 24 RP

For flow control, the AS 8 is set to the target flow; the volume counter measures the actual flow and returns pulses. The output goes to a steady valve through a regulating transformer, or it changes the speed of a transfer pump, which holds the flow through a component constant.

For speed control, the target speed is set on the unit and the rotary encoder on the shaft returns the actual speed as square-wave pulses; the output drives a frequency converter. The display shows speed in 1 per minute, for example 1000 1/min in the datasheet picture.

In both cases two relay contacts report when the permissible error tolerances are exceeded and the control system can be switched on and off from outside.

Differences between AS 8 I 24 RP and other AS 8 programs

The RP program is the only one in the series that closes a control loop with a valve or drive; DOS closes a valve once, D2F and A2F merely display, and ZM only reports stroke. Unlike the 230 V versions, this code runs on 24 VDC, so it can be fed from the same supply as the sensors in a machine cabinet.

Because this version has no keyboard letter F, setting is done with buttons that become accessible after the front panel is removed; the membrane version would show F in the code.

Where AS 8 I 24 RP is applied

Examples are flow control through filters or test components, pump speed control in transfer systems, and spindle speed holding on small drives. In the Gulf, skid builders use units like this to hold a constant oil flow through a cooler or a filter test stand while ambient temperature changes the oil viscosity.

The analogue output is used as a setpoint for a proportional valve or a frequency converter, so no PLC is needed for a stand-alone loop.

As a worked example, a filter test stand must pass exactly 20 l/min through the element under test while the oil warms from cold to operating temperature. The oil viscosity falls as it warms, so with a fixed pump speed the flow would rise. The RP version reads the volume counter, compares it with the 20 l/min target and lowers the pump speed through the frequency converter, keeping the flow constant and the test valid.

The analogue output of this code is a current, which is less sensitive to cable length than a voltage signal and therefore a good fit for cabinets that are some distance from the frequency converter or valve amplifier.

Selection and compatibility

Match the output to the actuator: use the current output for a proportional valve amplifier or frequency converter that accepts 0 to 20 mA or 4 to 20 mA. Inputs accept 24 V incremental signals from 1 Hz to 2,500 Hz. The encoder supply of 24 V and 50 mA powers a volume counter or rotary encoder directly.

The instrument is not a substitute for safety shut-off; use it for process control only.

Think about the dynamic behaviour of the loop: a large volume of oil between valve and counter makes the loop slow, and a small pump on a long line may need a gentle tuning. Test with the real system before releasing it.

Fitting and tuning AS 8 I 24 RP

Install in a 92 x 45 mm panel cut-out with 122 mm depth. Connect supply, encoder and output, set the display unit and pulse factor, enter the target and observe how the actual value settles. Adjust the control parameters until the output does not hunt.

Maintenance of AS 8 I 24 RP

No wear parts are present. Check the encoder cable and the output wiring periodically and keep the temperature in the cabinet within 0 to 60 C.

Ordering notes and related items

Order AS 8 I 24 RP together with the matching volume counter or encoder. Related units: AS 8 U 230 DOS / F, AS 8 I 24 ZM / F and AS 8 U 230 PUR / F.

Documents and quotation

The datasheet is attached to this page. Send an RFQ for AS 8 I 24 RP and the quantity to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.

Typical Questions From Maintenance Teams

Maintenance engineers replacing a KRACHT AS 8 I 24 RP usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed flow computers, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.

Other Models in the Kracht As8 Electronics Range

Seven Star LLC supplies models from the Kracht As8 Electronics range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
KRACHT AS 8 I 24 ZM / F Cylinder Stroke Measuring UnitFlow ComputersView details
KRACHT AS 8 U 230 DOS / F Dosing Controller 230 VFlow ComputersView details
KRACHT AS 8 I 24 RP Flow and Speed Controller 24 VDCFlow ComputersYou are viewing this model
KRACHT AS 8 U 24 D2F / F Flow Difference DisplayFlow ComputersView details
KRACHT AS 8 U 230 PUR / F Mixing Ratio ControllerFlow ComputersView details
KRACHT SD 1 R 24 Plug-On Flow Display Square-Wave OutputFlow ComputersView details
Datasheets & Documents
  • PDF Datasheet KRACHT AS 8 I 24 RP Flow and Speed Controller 24 VDC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.

Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.

KRACHT company profile

Founded 1911, registered as Hillebrand & Kracht OHG
Headquarters Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971
Ownership Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company
Size About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco
Subsidiaries USA, China and Hungary (KRACHT Hidraulik Kft.)
Product families External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders

Milestones

  • 1911: Hillebrand & Kracht OHG is entered in the trade register.
  • 1971: The company moves into its present premises in Werdohl.
  • 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
  • 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.

KRACHT pumps, flow meters and valves listed

The listing follows four product groups, pumps, fluid measurement, valves and drives:

  • Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
  • Fluid measurement technology: gear type flow meters such as the VCA in aluminum
  • Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
  • Drive technology: KM hydraulic gear motors

Where KRACHT equipment is used

KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.

KRACHT products we list

Family Examples
Pumps BT / BTH Low-Speed Gear Pump, DT DuroTec Gear Pump for Abrasive Fluids, KD1 Gear Metering Pump, KF 0 Stainless Steel Process Gear Pump, KF Series Modular Gear Pump, KF-F Fuel Gear Pump Series, KF80RF2-D15 Gear Pump, KM Series Hydraulic Gear Motor and 2 more
Flowmeters Fluid Measurement Technology Series, SVC Screw Type Flow Meter, TM Turbine Flow Meter, VC 0.01 Micro Gear Type Flow Meter, VC Gear Type Flow Meter, VCA Aluminum Gear Flow Meter, VCM Gear Flow Meter
Safety Relief Valves DBD Directly Controlled Poppet Valve, DV B Hydraulically Pilot Controlled Valve, HV/HVF Pilot Operated Slide Valve, SPV 10 L1G 1 A 12 Pressure Relief Valve, SPV/SPVF Directly Controlled Slide Valve, Valve Technology Series
Hydraulic Valves & Components CNL Hydraulic Cylinder, DV S Pressure Stage Control Valve
Gear Units & Reducers Drive Technology Series

Ordering KRACHT parts: what we need

KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.

Frequently requested KRACHT models: KRACHT Pump Technology Series.

Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.

FAQ

Questions about the KRACHT AS 8 I 24 RP Flow and Speed Controller 24 VDC

Answers from our engineering team on installation, compatibility and integration.

01What does the RP version of KRACHT AS 8 I 24 RP control?
It controls flow with a volume counter, or speed with a rotary encoder, by adjusting an analogue output.
02What output does AS 8 I 24 RP provide?
The code I gives a current output; the datasheet lists plus-minus 20 mA, 0 to 20 mA and 4 to 20 mA, and two relay contacts.
03How is AS 8 I 24 RP powered?
From 24 VDC, and it supplies 24 V at 50 mA to the encoder.
04What do the relays of AS 8 I 24 RP signal?
Two relay contacts report when the permissible error tolerances are exceeded.
05How is AS 8 I 24 RP operated?
Through three buttons behind the front panel, because the code has no F for the membrane keyboard.