- Automation & ControlView all 3,053 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Hydac
Hydac HDA 4775-A-5000-000 High-Pressure Transducer 5000 psi
Description
Hydac HDA 4775-A-5000-000 measures up to 5000 psi (about 345 bar) with a two-wire 4 to 20 mA output. It is the highest-range member of the SAE-6 group listed here and is meant for presses, intensifiers and high-pressure hydraulic test equipment. The cell survives 11600 psi of overload and does not burst until 29000 psi. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Characterising HDA 4775-A-5000-000
At 5000 psi the accuracy of 0.25 percent of full scale equals 12.5 psi. The temperature coefficient of 0.008 percent per degC typical gives about 0.4 psi of change for every degree away from the compensated midpoint. Repeatability of 0.05 percent corresponds to 2.5 psi. Together those figures describe a transmitter that is better than a mechanical gauge and fully adequate for high-pressure control loops.
High-pressure work calls for discipline. Always depressurise the circuit before fitting or removing the transmitter, never use the instrument body as a lever and make sure the cable does not hang on the connector. If the system includes a fast-acting valve, consider a restrictor in front of the port to flatten pressure peaks, which protects both the cell and the accuracy of readings on the HDA 4775 unit.
Features of HDA 4775-A-5000-000
- Range 5000 psi, overload 11600 psi, burst 29000 psi.
- Thin-film cell on a welded stainless membrane.
- Loop powered, 8 to 30 V DC, 25 mA or less.
- SAE-6 male port, tightened to 20 N·m.
- Plug supplied, IP 67 when mated.
- Rise time 1 ms or less.
Specification table for HDA 4775-A-5000-000
| Parameter | Value |
|---|---|
| Model code | HDA 4775-A-5000-000 |
| Material number (catalog) | 907189 |
| Measuring range | 0 to 5000 psi |
| Overload pressure | 11600 psi |
| Burst pressure | 29000 psi |
| Process connection | 9/16-18 UNF 2A male (SAE 6) |
| Tightening torque | 15 lb-ft (20 N·m) |
| Output signal | 4 to 20 mA, 2-wire; load RLmax = (UB – 8 V) / 20 mA in kOhm |
| Supply voltage | 8 to 30 V DC, ripple 5 percent or less |
| Current consumption | 25 mA or less |
| Accuracy (terminal based) | 0.25 percent FS typical and maximum at max. setting |
| Accuracy (best-fit line) | 0.15 percent FS typical, 0.25 percent maximum |
| Temperature coefficient | 0.008 percent FS per degC typical, 0.015 maximum (zero and span) |
| Non-linearity / hysteresis | 0.3 / 0.1 percent FS maximum |
| Repeatability | 0.05 percent FS |
| Rise time | 1 ms or less |
| Long-term drift | 0.1 percent FS per year typical |
| Electrical connection | EN175301-803 (DIN 43650), 3-pole + PE, mating connector supplied |
| Pins | 1 signal +, 2 signal -, 3 not connected, earth = housing |
| Protection class | IP 67 with the mating connector fitted |
| Wetted parts | Stainless steel connection; FKM seal |
| Compensated temperature | -13 to 185 degF |
| Fluid temperature | -13 to 212 degF |
| Storage temperature | -40 to 212 degF |
| Vibration | 20 g, 10 to 500 Hz |
| Life expectancy | more than 10 million cycles, 0 to 100 percent FS |
| Weight | about 145 g |
Applications
Typical locations are pressure intensifier outputs, high-pressure test stands, hydraulic tensioning tools and water-jet pumps. In heavy-industry plants in the GCC, the instrument tracks supply pressure for forging presses. Choose a flameproof model for classified zones, because HDA 4775-A-5000-000 carries only general-purpose CE marking.
How HDA 4775-A-5000-000 differs from 3000 psi and lower versions
The 3000 psi part has 7250 psi overload and 14500 psi burst. This 5000 psi part increases both by a factor of 1.6 to 2 and widens the error band from 7.5 to 12.5 psi. Compared with 0750 and 1000 psi the span is more than five times larger. The mechanical, electrical and temperature data stay the same.
Selection
Use this part only when working pressure exceeds about 3000 psi. For smaller working pressures the lower ranges give better resolution. The mating block must be rated for 5000 psi and equipped with an SAE-6 port and O-ring face.
Installation
Check the block for burrs, fit a new O-ring, torque to 20 N·m and fit the connector. Protect the cable from heat sources, apply power and verify 4 mA at zero pressure and 20 mA at 5000 psi using a calibrated reference on HDA 4775-A-5000-000.
Maintenance
Do not exceed the 11600 psi overload during pressure tests. Verify zero annually, renew the O-ring on every removal and replace the unit if drift exceeds the 0.25 percent limit.
Calibration practice: for a high-range device, use a deadweight tester or a calibrated digital reference at 0, 1250, 2500, 3750 and 5000 psi, and record both rising and falling values. Hysteresis is specified at 0.1 percent of full scale maximum, which is 5 psi at this range. Keep the material number 907189 on the calibration certificate so that the part can be traced to the catalog entry. Output linearity is quoted as 0.3 percent of full scale at most, so a three-point check is the minimum. Document the supply voltage during the test as well, since the permitted loop load depends on it.
Delivery to Sites in Oman and the GCC
Delivery of the Hydac HDA 4775-A-5000-000 is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive pressure transmitters equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.
Selection Notes for the Hydac HDA 4775-A-5000-000
When comparing the Hydac HDA 4775-A-5000-000 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Hydac pressure transmitters range and confirm the correct order code before you commit.
Frequently asked questions about HDA 4775-A-5000-000
What is the burst pressure of HDA 4775-A-5000-000? 29000 psi, with an overload pressure of 11600 psi.
Which thread does it use? SAE-6 9/16-18 UNF 2A male, torque 20 N·m.
How is the instrument supplied electrically? From 8 to 30 V DC on a two-wire 4 to 20 mA loop through the EN175301-803 connector.
What happens above 9000 psi? The datasheet extends rise time to under 1.5 ms above 9000 psi; this part is below that range.
How do I request a quote? Send an RFQ naming HDA 4775-A-5000-000 with quantity and delivery location.
Documents and quotation
The datasheet for HDA 4775-A-5000-000 is attached. Send an RFQ with HDA 4775-A-5000-000, quantity and delivery site to receive availability and lead time.
Other Models in the HDA 4700 Range
Seven Star LLC supplies models from the HDA 4700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Hydac HDA 4775-A-3000-000 Pressure Transmitter 3000 psi, SAE-6 | Pressure Transmitters | View details |
| Hydac HDA 4775-A-1000-000 Pressure Transducer 1000 psi, 4-20 mA | Pressure Transmitters | View details |
| Hydac HDA 4775-A-5000-000 High-Pressure Transducer 5000 psi | Pressure Transmitters | You are viewing this model |
| Hydac HDA 4775-A-0750-000 Pressure Transmitter 750 psi, SAE-6 | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Hydac HDA 4775-A-5000-000 High-Pressure Transducer 5000 psi Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac HDA 4775-A-5000-000 High-Pressure Transducer
Answers from our engineering team on installation, compatibility and integration.
01What is the burst pressure of HDA 4775-A-5000-000?
29000 psi, with an overload pressure of 11600 psi.
02Which thread does it use?
SAE-6 9/16-18 UNF 2A male, torque 20 N·m.
03How is the instrument supplied electrically?
From 8 to 30 V DC on a two-wire 4 to 20 mA loop through the EN175301-803 connector.
04What happens above 9000 psi?
The datasheet extends rise time to under 1.5 ms above 9000 psi; this part is below that range.
05How do I request a quote?
Send an RFQ naming HDA 4775-A-5000-000 with quantity and delivery location.


















Reviews
There are no reviews yet.