Brand: Hydac
Hydac HDA 47F9-A-0100-DV-000 Flameproof Pressure Transmitter 100 psi
Description
Hydac HDA 47F9-A-0100-DV-000 is the lowest-range member of the flameproof HDA 4700 transmitter line, built to turn 0 to 100 psi of process pressure into a two-wire 4 to 20 mA signal inside a hazardous area. The housing is a welded 316L stainless enclosure with a 1/2-14 NPT conduit entry, so the transmitter can be run in rigid conduit straight to a junction box. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
The part number is easy to read once the order key is known. The leading 47 is the series, F selects a 1/4-18 NPT female process port, 9 selects the 1/2-14 NPT conduit with single cores, A is the 4 to 20 mA signal, 0100 is the range in psi, D is the triple approval and V marks the vented gauge cell. The closing 000 is the standard modification.
Overview of HDA 47F9-A-0100-DV-000
Where many ranges of this family start at several hundred psi, HDA 47F9-A-0100-DV-000 serves low-pressure points: hydraulic accumulator pre-charge checks, lube oil supply headers, nitrogen blanketing lines and gas pilot circuits in mines and process plants. Hydac builds the measuring cell from a fully welded stainless membrane with thin-film strain gauges and no internal seals, which is why a very small cell still survives an overload of 290 psi and a burst pressure of 1450 psi.
Because the cell is vented, the reading is a gauge value against surrounding air. That suits a 100 psi span well, since a sealed cell would add an absolute offset that matters when the scale is this small.
Key features of the HDA 47F9-A-0100-DV-000
- Triple approval on one nameplate: ATEX KEMA 10ATEX100 X, CSA MC 224264 and IECEx KEM 10.0053X.
- Accuracy of 0.25 percent of full scale (terminal based) with a best-fit straight-line figure of 0.15 percent typical.
- Rise time of 1.5 ms or less and long-term drift of 0.1 percent of full scale per year.
- Single-core conduit wiring: red signal plus, black signal minus, green-yellow housing.
- Supply from 8 to 30 V DC with reverse-polarity, overvoltage and short-circuit protection.
- Wetted stainless steel 1.4542, 1.4571, 1.4435, 1.4404 and 1.4301 with an FKM seal.
Technical specifications of HDA 47F9-A-0100-DV-000
| Parameter | Value |
|---|---|
| Model code | HDA 47F9-A-0100-DV-000 |
| Material number (catalog) | 921926 |
| Measuring range | 0 to 100 psi |
| Overload pressure | 290 psi |
| Burst pressure | 1450 psi |
| Cell type | Vented gauge (V) |
| Process connection | 1/4-18 NPT, female |
| Tightening torque | 30 lb-ft (40 N·m) |
| Electrical connection | 1/2-14 NPT conduit, single cores |
| Cores / cable | red, black, green-yellow; signal plus, signal minus, housing |
| Output | 4 to 20 mA, 2-wire, load RLmax = (UB – 8 V) / 20 mA in kOhm |
| Supply voltage | 8 to 30 V DC, residual ripple 5 percent or less, about 25 mA |
| Accuracy (terminal based) | 0.25 percent FS typical and maximum; best-fit line 0.15 percent typical |
| Non-linearity / hysteresis / repeatability | 0.3 / 0.1 / 0.05 percent FS maximum |
| Temperature coefficient (zero, span) | 0.008 percent FS per degC typical, 0.015 maximum |
| Rise time / long-term drift | 1.5 ms or less / 0.1 percent FS per year |
| Wetted parts | Stainless steel 1.4542, 1.4571, 1.4435, 1.4404, 1.4301; FKM seal |
| Housing / conduit | 1.4404 and 1.4435 (316L) |
| Compensated temperature | T5 / T130: -13 to 176 degF; T6 / T110: -13 to 140 degF |
| Operating and fluid temperature | T5: -4 to 176 degF; T6: -4 to 140 degF (FKM seal) |
| Storage temperature | -40 to 212 degF |
| Protection | IP 65 (vented gauge) |
| Vibration | 20 g, 10 to 500 Hz |
| Weight | 0.661 lb (about 300 g) |
| Approvals | ATEX KEMA 10ATEX100 X; CSA MC 224264; IECEx KEM 10.0053X |
Applications in oil, gas, mining and utilities
In Oman and the wider GCC the typical call for HDA 47F9-A-0100-DV-000 is the low end of a skid: a gas-turbine fuel gas regulator station, a flare knock-out drum purge line, or a lube-oil console where a pressure switch is not enough and the DCS needs a continuous value. Underground and hard-rock mining use the I M2 category, while desalination and power sites with dust or gas classification use the group II marks. The device ships with open leads, so the supplier of the junction box decides the final gland and sealing arrangement.
How HDA 47F9-A-0100-DV-000 differs from other HDA 4700 flameproof variants
Inside the flameproof family the difference is concrete. Against HDA 47F9-A-0300-DV-000 the range drops from 300 to 100 psi and the burst figure falls from 2900 to 1450 psi. Against the 478G versions the process port is female rather than male, and against 47FG the wiring is single cores with a green-yellow earth core instead of four flying leads. The 477G variant uses an SAE 6 male port and a 20 N·m torque; HDA 47F9-A-0100-DV-000 instead needs 40 N·m on the 1/4 NPT female thread.
Selection and compatibility notes
Check that the mating thread on the process side is a 1/4-18 NPT male stub, because HDA 47F9-A-0100-DV-000 has a female thread. Use a pipe-thread sealant compatible with the medium rather than PTFE shred, and avoid media that attack FKM. If the tank can see vacuum, remember that the cell is a vented gauge type and read the datasheet range statement. For pulsating lines of more than 100 psi peaks, choose a higher range from the same series, since 290 psi overload is the limit.
Installation and commissioning
Fit the instrument hand-tight, then torque to 40 N·m using the hex only. Route the conduit into a certified enclosure, strip the red, black and green-yellow cores and connect them to a loop supply between 8 and 30 V DC; the loop resistance may not exceed (UB minus 8 V) divided by 20 mA. Earth the housing core. With the loop powered, check 4 mA at zero pressure and 20 mA at 100 psi before closing the junction box, and keep a record of the certificate numbers for the dossier of HDA 47F9-A-0100-DV-000.
Maintenance and service life
The datasheet quotes a life expectancy above 10 million load cycles from 0 to 100 percent of range, and the unit has no user-serviceable parts. A yearly zero check with the process vented is usually enough. Do not open the flameproof enclosure; replacement of HDA 47F9-A-0100-DV-000 is by exchange. Keep the venting point of the vented cell free of paint and contamination.
Related flameproof parts in the same range cover 0300, 0500 and higher psi values with the same order key. Mating cable glands, junction boxes and the HYDAC display units are separate items. Spare and obsolete part numbers can be checked against the family key before ordering, and we compare your tag data with the code of HDA 47F9-A-0100-DV-000 in writing.
Frequently asked questions about HDA 47F9-A-0100-DV-000
What does the 0100 in HDA 47F9-A-0100-DV-000 mean? It is the measuring range in psi. The transmitter spans 0 to 100 psi on its 4 to 20 mA output, and the catalog lists a 290 psi overload and 1450 psi burst pressure for this range.
Why is this unit a vented gauge cell? The D V block of the order code means flameproof approval plus a vented gauge cell. The datasheet reserves the vented cell for ranges up to 300 psi, so the 100 psi version references atmosphere through the venting point in the 1/2-14 NPT conduit housing.
Which wiring applies to the single cores? Variant 47F9 has single cores in the conduit: red is signal plus, black is signal minus and green-yellow is the housing connection.
Can I use it in a coal mine and in a gas zone? The marking covers I M2 Ex d I Mb for mining, II 2G Ex d IIC T6 or T5 Gb for gas and II 2D Ex tb IIIC for dust, so one instrument carries all three, provided the installer follows the certificate conditions.
What should I send for a quotation on HDA 47F9-A-0100-DV-000? Send the full part number HDA 47F9-A-0100-DV-000, the quantity, the delivery location and whether you need the datasheet attached. Seven Star LLC answers with availability.
Documents and quotation
The datasheet for HDA 47F9-A-0100-DV-000 is attached on this page. For a quotation send an RFQ with part number HDA 47F9-A-0100-DV-000, quantity, delivery site and required documents. Replies state availability and lead time without publishing a price.
Other Models in the HDA 4700 ExD Range
Seven Star LLC supplies models from the HDA 4700 ExD range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Hydac HDA 478G-A-0200-DV-000 Ex d Transmitter, 1/4 NPT Male | Pressure Transmitters | View details |
| Hydac HDA 478G-A-0300-DV-000 Flameproof Transmitter 300 psi | Pressure Transmitters | View details |
| Hydac HDA 47FG-A-0200-DV-000 Flameproof Transmitter, Flying Leads | Pressure Transmitters | View details |
| Hydac HDA 477G-A-0300-DV-000 SAE-6 Flameproof Transmitter | Pressure Transmitters | View details |
| Hydac HDA 47F9-A-0300-DV-000 Ex d Pressure Transmitter 300 psi | Pressure Transmitters | View details |
| Hydac HDA 47F9-A-0100-DV-000 Flameproof Pressure Transmitter 100 psi | Pressure Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Hydac HDA 47F9-A-0100-DV-000 Flameproof Pressure Transmitter 100 psi Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac HDA 47F9-A-0100-DV-000 Flameproof Pressure
Answers from our engineering team on installation, compatibility and integration.
01What does the 0100 in HDA 47F9-A-0100-DV-000 mean?
It is the measuring range in psi. The transmitter spans 0 to 100 psi on its 4 to 20 mA output, and the catalog lists a 290 psi overload and 1450 psi burst pressure for this range.
02Why is this unit a vented gauge cell?
The D V block of the order code means flameproof approval plus a vented gauge cell. The datasheet reserves the vented cell for ranges up to 300 psi, so the 100 psi version references atmosphere through the venting point in the 1/2-14 NPT conduit housing.
03Which wiring applies to the single cores?
Variant 47F9 has single cores in the conduit: red is signal plus, black is signal minus and green-yellow is the housing connection.
04Can I use it in a coal mine and in a gas zone?
The marking covers I M2 Ex d I Mb for mining, II 2G Ex d IIC T6 or T5 Gb for gas and II 2D Ex tb IIIC for dust, so one instrument carries all three, provided the installer follows the certificate conditions.
05What should I send for a quotation on HDA 47F9-A-0100-DV-000?
Send the full part number HDA 47F9-A-0100-DV-000, the quantity, the delivery location and whether you need the datasheet attached. Seven Star LLC answers with availability.