ABB 1SBL177201R1300 AF16-40-00-13 4-Pole Contactor, 4 N.O., 30 A AC-1
Description
ABB 1SBL177201R1300: four normally open poles in an AF16 body
ABB 1SBL177201R1300 is the AF16-40-00-13, a contactor with four normally open main poles. The extra fourth pole is what the “40” in the type indicates, in contrast to the three-pole AF16-30 versions. It is meant for circuits in which the neutral is switched together with the phases, for single-phase and three-phase heating banks, lighting groups and other loads that the datasheet describes as non-inductive or slightly inductive.
The rating is given as AC-1 current: 30 A at up to 60 degrees C ambient and 26 A at 70 degrees C, with a thermal current of 35 A on 6 mm2 conductors. The contactor is made for up to 690 V AC and 440 V DC. Its coil is the 13 type for 100-250 V AC/DC with electronic interface.
Think of 1SBL177201R1300 as the neutral-switching counterpart of the AF16 three-pole motor contactors: it shares the coil system, the coil consumption of about 50 VA to pull in and 2.2 VA to hold, and the 35 mm rail clip, so the control wiring in a panel stays the same when a fourth pole is needed.
What the 1SBL177201R1300 provides
- Four N.O. main poles for three phases plus neutral.
- AC-1 current 30 A at 40 and 60 degrees C, 26 A at 70 degrees C.
- Short-time withstand 300 A for 1 s, 150 A for 10 s, 80 A for 30 s, 60 A for 1 min and 35 A for 15 min.
- UL general use 30 A at 600 V AC on AWG 10.
- Weight 0.270 kg, same as the AF09 frame.
1SBL177201R1300 data overview
| Order code | 1SBL177201R1300 |
|---|---|
| Type | AF16-40-00-13 |
| Main poles | 4 N.O. |
| Coil | 100-250 V 50/60 Hz / DC |
| Rated voltage Ue | 690 V AC |
| AC-1 current, 40 C | 30 A |
| AC-1 current, 60 C | 30 A |
| AC-1 current, 70 C | 26 A |
| Thermal current Ith | 35 A (6 mm2) |
| gG fuse | 32 A |
| Icw 1 s / 10 s | 300 A / 150 A |
| Icw 30 s / 1 min / 15 min | 80 A / 60 A / 35 A |
| Power loss per pole | 1.2 W |
| Switching frequency AC-1 | 600 cycles per hour |
| UL general use | 30 A, 600 V AC |
| Main terminal screws | M3.5, 1.5 Nm |
| Conductors, rigid / flexible with ferrule | 1-6 mm2 / 0.75-6 mm2 |
| Stripping length | 10 mm |
| Mechanical life | 10 million cycles |
| Weight | 0.270 kg |
How 1SBL177201R1300 compares with AF09-22 and AF26-22
All three are four-pole contactors for non-inductive loads, but the pole arrangement differs: the AF16-40 has four N.O. poles, the AF09-22 and AF26-22 have two N.O. and two N.C. Current also differs: AC-1 is 30 A here, 25 A on the AF09-22 and 45 A on the AF26-22. Because all poles are N.O. on AF16-40-00-13, it is the one to choose when neutral must be switched simultaneously.
Applications
Heating banks in process skids, electric heaters for tank tracing in Omani oil and gas facilities, lighting groups in car parks and workshops and resistive test loads in laboratories are the standard matches. With the neutral switched, the contactor also provides a clear isolation point that satisfies local rules on four-wire installations.
Notes on selection
The coil data matter for the control design. The AF coil takes an average of 50 VA or 50 W to pull in and 2.2 VA or 2 W to hold, the contactor closes its N.O. poles within 40 to 95 ms of energisation and opens them within 11 to 95 ms of de-energisation, and the drop-out voltage is at or below 60 percent of the minimum coil voltage. With a PLC output that delivers only 24 V DC and 500 mA, the Z version of the AF coil family is the one that can be driven directly, so do not expect 1SBL177201R1300 with its 100-250 V coil to run from such an output; use an interposing relay from the CR range instead.
The environment is generous: operation without an overload relay is allowed from -40 to +70 degrees C and storage from -60 to +80 degrees C, up to 3000 m altitude, with shock withstand of 30 g in the main mounting position and vibration withstand of 4 g closed and 2 g open between 5 and 300 Hz. Rated insulation voltage is 690 V (600 V UL) with a 6 kV impulse rating.
Do not use the AC-1 rating for motors; inductive loads require derating or a motor-rated contactor from the AF16-30 series with AC-3 data. Remember that the ambient temperature next to the contactor determines the current; in a hot panel in the Gulf summer the 70 degrees C figure of 26 A may apply. Short-circuit protection with a gG fuse of 32 A is stated for supply voltages up to 500 V AC.
Installation and care
Fix on 35 mm rail or with two M4 screws; torque main terminals to 1.5 Nm and coil terminals to 1.2 Nm. Check the poles for discoloration and pitting at each planned shutdown, listen for abnormal coil hum, confirm that all four poles close together by measuring each one with the coil energised, and replace the whole contactor rather than a single pole if any contact shows heavy wear. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about 1SBL177201R1300
How many poles does 1SBL177201R1300 have? Four main poles, all normally open, as the 40 in the type code indicates.
What is the AC-1 rating of 1SBL177201R1300? 30 A up to 60 degrees C and 26 A at 70 degrees C, with 35 A thermal current.
Is 1SBL177201R1300 for motor control? It is intended for non-inductive or slightly inductive loads; motors need AC-3 rated contactors such as the three-pole AF16-30 versions.
What coil does 1SBL177201R1300 use? A 100-250 V 50/60 Hz and DC coil with electronic interface.
What is the weight of 1SBL177201R1300? The datasheet lists 0.270 kg per piece, the same as the AF09 frame contactors.
Documents and quotation
Download the technical datasheet for 1SBL177201R1300 here. For a quotation, send an RFQ listing part number 1SBL177201R1300, quantity and delivery point.
Other Models in the Abb Af Range
Seven Star LLC supplies models from the Abb Af range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB 1SBL237001R1311 AF26-30-11-13 Contactor 11 kW, 1 N.O. + 1 N.C. | Contactors & Overload Relays | View details |
| ABB 1SBL157001R1301 AF12-30-01-13 Contactor 5.5 kW, 1 N.C. Built-in | Contactors & Overload Relays | View details |
| ABB 1SBL137501R1300 AF09-22-00-13 4-Pole Contactor, 2 N.O. + 2 N.C. | Contactors & Overload Relays | View details |
| ABB 1SBL297501R1300 AF38-22-00-13 4-Pole Contactor, 55 A AC-1 | Contactors & Overload Relays | View details |
| ABB 1SBL237501R1300 AF26-22-00-13 4-Pole Contactor, 45 A AC-1 | Contactors & Overload Relays | View details |
| ABB 1SBL177201R1300 AF16-40-00-13 4-Pole Contactor, 4 N.O., 30 A AC-1 | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet ABB 1SBL177201R1300 AF16-40-00-13 4-Pole Contactor, 4 N.O., 30 A AC-1 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB 1SBL177201R1300 AF16-40-00-13 4-Pole Contactor,
Answers from our engineering team on installation, compatibility and integration.
01How many poles does 1SBL177201R1300 have?
Four main poles, all normally open, as the 40 in the type code indicates.
02What is the AC-1 rating of 1SBL177201R1300?
30 A up to 60 degrees C and 26 A at 70 degrees C, with 35 A thermal current.
03Is 1SBL177201R1300 for motor control?
It is intended for non-inductive or slightly inductive loads; motors need AC-3 rated contactors such as the three-pole AF16-30 versions.
04What coil does 1SBL177201R1300 use?
A 100-250 V 50/60 Hz and DC coil with electronic interface.
05What is the weight of 1SBL177201R1300?
The datasheet lists 0.270 kg per piece, the same as the AF09 frame contactors.