Brand: AMETEK
AMETEK 7002-004-KE WDG-V UOP Acid Coated Zirconia Cell
Description
AMETEK 7002-004-KE overview
AMETEK 7002-004-KE is the acid coated cell for the Thermox WDG-V UOP analyzer. The WDG-V UOP/RP is the analyzer AMETEK has designed for oxygen measurement in continuous catalytic regeneration (CCR) platforming units, a process the datasheet describes in detail. The datasheet states that dual isolation valves allow the sensor to be replaced without shutting down the CCR process. The AMETEK listing is short and names only the acid coated cell for the WDG-V UOP, so the cell matches the UOP analyzer platform rather than the standard flue gas WDG-V.
The WDG-V UOP/RP is the AMETEK oxygen analyzer for continuous catalytic regeneration (CCR) platforming processes. The datasheet describes a nitrogen-operated aspirator that draws a sample from the catalyst regenerator, a zirconia sensor, Hastelloy probe tube, heated wetted parts and dual isolation valves so the sensor can be replaced without shutting down the process.
Key features of 7002-004-KE
- Acid coated zirconia cell for the WDG-V UOP/RP analyzer
- Intended for CCR platforming oxygen control
- Replaceable through dual isolation valves without a process shutdown (datasheet)
- Hastelloy probe tube and 316 SS wetted parts on the analyzer
- Different from the standard WDG-V cell 7000-568-SE
- Nitrogen-aspirated sampling design
7002-004-KE technical specifications
| Item | Detail |
|---|---|
| Part number | 7002-004-KE |
| Description | Acid coated cell, WDG-V UOP |
| Analyzer (datasheet) | WDG-V UOP/RP CCR oxygen analyzer |
| Principle | Zirconium oxide, nitrogen-aspirated |
| Accuracy (datasheet) | Plus or minus 0.75 percent of measured value or plus or minus 0.05 percent oxygen, whichever is greater |
| Response (datasheet) | 90 percent of a process step change in less than 12 seconds |
| Principle (datasheet) | Nitrogen-aspirated zirconium oxide net O2 analyzer |
| Output range | 0-1 percent to 0-100 percent O2 |
| Drift | Less than 0.1 percent of cell output per month |
| Aspirator requirement | Nitrogen, 10-20 scfh |
| Sample pressure | 14.69 psig up to 60 psig |
| Probe | Hastelloy C, 18 inch or 27 inch |
| Max sample dew point | 200 degrees C (392 degrees F) |
| Enclosure | Hinged IP65 |
Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 7002-004-KE. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.
Typical applications in oil and gas, utilities, water and manufacturing
The datasheet names continuous catalytic regeneration and catalytic reforming or platforming as the applications, in the petrochemical and refining markets. Refineries and aromatics plants in the GCC that run CCR units rely on an accurate oxygen measurement to control catalyst burn-off.
Where 7002-004-KE is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.
Selection and compatibility notes for 7002-004-KE
Confirm that the analyzer is the UOP/RP version and the area classification option (ATEX/IECEx or Class 1 Div 2 manuals exist) before ordering parts.
Part number 7002-004-KE is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.
Installation and commissioning
Use the cell replacement instructions of the WDG-V UOP user manual together with the process procedure for your unit. The datasheet notes that the dual isolation valves allow the sensor to be replaced without shutting down the CCR process, so follow the plant isolation practice, fit the cell as the manual describes and calibrate afterwards with the zero and span gases specified for the analyzer (the datasheet gives air or 1.0 to 100 percent O2 for span and 2 percent or 0.1 to 10 percent O2 for zero).
Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 7002-004-KE. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.
Maintenance and service life
The datasheet gives drift of less than 0.1 percent of cell output per month, so cell health is tracked by the diagnostics. Plan a spare of 7002-004-KE for CCR units where the oxygen measurement controls catalyst burn-off.
Related products and ordering notes
See the UOP analyzer manuals and the datasheet for probe sizes, which are 18 inch or 27 inch Hastelloy C.
For a spare parts plan, list 7002-004-KE against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.
Operators in Oman and the Gulf work in high ambient temperatures, dust and humidity, and sites often plan turnarounds months ahead, so confirming the exact number of every spare before the shutdown window is valuable. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer, and we handle enquiries for hard-to-find and legacy numbers directly.
Frequently asked questions about 7002-004-KE
- What is AMETEK 7002-004-KE? It is the acid coated cell for the Thermox WDG-V UOP analyzer used in CCR platforming oxygen measurement.
- Where is the WDG-V UOP used? The datasheet describes continuous catalytic regeneration (CCR) and catalytic reforming or platforming in refining and petrochemical plants.
- Can the cell be replaced online? The datasheet says dual isolation valves allow the sensor to be replaced without shutting down the CCR process.
Documents and quotation
The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 7002-004-KE, send the RFQ with the part number 7002-004-KE, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.
Datasheets & Documents
- Datasheet AMETEK WDG-V UOP/RP CCR Oxygen Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK 7002-004-KE WDG-V UOP Acid Coated Zirconia
Answers from our engineering team on installation, compatibility and integration.
01What is AMETEK 7002-004-KE?
It is the acid coated cell for the Thermox WDG-V UOP analyzer used in CCR platforming oxygen measurement.
02Where is the WDG-V UOP used?
The datasheet describes continuous catalytic regeneration (CCR) and catalytic reforming or platforming in refining and petrochemical plants.
03Can the cell be replaced online?
The datasheet says dual isolation valves allow the sensor to be replaced without shutting down the CCR process.
04What is the stated accuracy?
Plus or minus 0.75 percent of measured value or plus or minus 0.05 percent oxygen, whichever is greater, per the datasheet.
05How do I request a quotation for 7002-004-KE?
Send the part number 7002-004-KE, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.