Brand:

ABB SH201-C16 1P MCB 16 A C Curve, SH200

Description

ABB SH201-C16 1P miniature circuit breaker, 16 A C curve

The ABB SH201-C16 is a 1P miniature circuit breaker rated 16 A with a C tripping characteristic, from the Compact Home SH200 series, which ABB describes for residential applications with breaking capacities up to 6 kA and rated currents up to 40 A. It protects cables and equipment against overload through a thermal release and against short circuit through an electromagnetic release, and it is current limiting. The order code is 2CDS211001R0164.

Its rated short-circuit capacity is 6 kA AC, its rated operational voltage is 230 V AC and its width on the DIN rail is 17.5 mm. The data lists energy limiting class 3, which reflects the let-through energy under fault.

ABB positions the SH200 as the Compact Home series for residential use, and the SH201-C16 is a 16 A single-pole breaker for lighting and socket circuits in apartments, villas and staff accommodation.

Reading the SH201-C16 type designation

The S200 family designation can be read like a short specification, which makes a comparison of options quick.

Code group Meaning
SH201 Series prefix; SH200 family
1 Number of poles in the type code, 1P
C Tripping characteristic C (general purpose)
16 Rated current 16 A

The C characteristic trips the electromagnetic release in the range of five to ten times the rated current in line with IEC/EN 60898-1, which suits most mixed loads including lighting, sockets, small motors and control transformers. B and D characteristics exist in the family for other inrush conditions.

SH201-C16 technical specifications

Parameter Specification
Manufacturer / part number ABB / SH201-C16
Order code / EAN 2CDS211001R0164 / 4016779630641
Product type Miniature circuit breaker, SH200 – 1P – 16 A – C – (AC) 6 kA
Number of poles 1P
Rated current In 16 A
Tripping characteristic C
Rated short-circuit capacity 6 kA AC
Rated operational voltage acc. to IEC 60898-1 230 V AC
Maximum operational voltage Maximum (Incl. Tolerance) 253 V AC
Energy limiting class 3
Rated impulse withstand voltage 4 kV
Power loss 2.5 W
Electrical / mechanical endurance 20000 AC cycle / 20000 cycle
Ambient air temperature Operation -25 to +55 °C
Terminal type Cage Terminal
Connecting capacity Conductor 25 / 25 mm²
Tightening torque 2 N·m
Mounting 35 mm DIN rail, TH35-15 acc. to IEC 60715
Dimensions W x H x D 17.5 mm x 85 mm x 69 mm
Net weight 0.105 kg
Accessories available No
Standards IEC/EN 60898-1

Values come from the ABB product page for the SH201-C16. Short-circuit values depend on the voltage and the pole count, so use the line that matches your system voltage.

How the SH201-C16 trips

The thermal element in the SH201-C16 bends with sustained overcurrent and trips with a delay that grows shorter as the overload increases, which gives time for motor or transformer starting currents while protecting the cable. The electromagnetic release acts without delay on a short circuit and, together with the current-limiting design, keeps the let-through energy low.

The toggle carries a contact position indication (listed by ABB as ON / OFF), which helps an operator tell the state at a glance. The mechanical endurance listed by ABB is {g(a,’Mechanical Endurance’)} and the electrical endurance is {g(a,’Electrical Endurance’)} at the rated conditions, which is a useful basis for planning inspection intervals.

In accommodation blocks, offices and site cabins in Oman it is a cost-conscious choice for final circuits, within the 6 kA rated short-circuit capacity of the range.

Where the SH201-C16 fits and which parts go with it

The SH201-C16 sits in a final-circuit or sub-distribution board, normally downstream of a main switch, an RCD or an incoming breaker. Because it is current limiting, it helps back-up protection and cascading with other devices; check the cascading tables of the manufacturer for the exact upstream device.

The ABB data lists no accessories for this series, so signalling contacts and trip units are not part of the type; plan for a different series if you need remote status or tripping.

Other types in the same family include SH203-C16, SH203-C32. This page covers the SH201-C16.

Selection checklist for the SH201-C16

  • Rated current: confirm that 16 A matches the cable cross-section and the connected load, including ambient derating.
  • Pole count: this is a 1P device, so check that the neutral and phase arrangement of the board matches.
  • Short-circuit capacity: the rated short-circuit capacity is 6 kA AC; compare it with the prospective fault level at the board.
  • Characteristic: C is suited to general loads; choose B for long cable runs with a low fault level and D for high inrush.
  • Accessories: ABB lists accessories as available: No. Decide on auxiliary or signalling contacts before you order.
  • Space: allow 17.5 mm of DIN rail width and the height of the board enclosure.

Installation, commissioning and maintenance of the SH201-C16

Clip the SH201-C16 onto a 35 mm DIN rail and, where used, a busbar; the connecting capacity listed by ABB is Conductor 25 / 25 mm². Use a Pozidriv 2 screwdriver and tighten terminals to 2 N·m.

At commissioning, close the breaker, check the voltage at the terminals and test the downstream device. Label every circuit with its load and cable size in the board schedule.

Maintain by inspecting terminals for tightness, discolouration and heating, and operate the toggle periodically to keep the mechanism free. Replace a breaker that has tripped on a heavy short circuit if there is any sign of damage to the housing or terminals.

Typical applications of the SH201-C16 in Oman and the GCC

ABB positions the SH200 as the Compact Home series for residential use, and the SH201-C16 is a 16 A single-pole breaker for lighting and socket circuits in apartments, villas and staff accommodation.

High enclosure temperatures are common in outdoor kiosks and rooftop boards. The ABB data lists an operating range of -25 to +55 °C, and breaker loading should be checked against the real board temperature, since thermal trips are sensitive to heat from neighbouring devices.

SH201-C16 and the neighbouring SH200 breakers

Type Poles Rated current Rated short-circuit capacity Width
SH201-C16 1P 16 A (AC) 6 kA 17.5 mm
SH203-C16 3P 16 A (AC) 6 kA 52.5 mm
SH203-C32 3P 32 A (AC) 6 kA 52.5 mm

The SH201-C16 is highlighted here for 1P protection at 16 A. If the load grows, move to the next current rating rather than changing the characteristic.

Information to send with an RFQ for the SH201-C16

  • Exact type SH201-C16 (order code 2CDS211001R0164), quantity and required delivery time.
  • Load current, cable size and the type of load.
  • Supply voltage, system earthing and prospective short-circuit current.
  • Accessories required, if any.
  • Board type and ambient temperature.
  • Documents needed with the order, for example datasheets.

Documents and quotation

The SH 200 miniature circuit breaker section of the official ABB Compact Home catalogue (document 9AKK107991A9809 Rev. C, May 2022, English) is attached on this page as a PDF and lists the ABB SH201-C16 by its ABB order code. It contains the SH 200 ordering tables for the B and C characteristics in one to four poles, the technical data, the tripping curves, the derating and power-loss values, the accessories and the dimension drawings. Check the number of poles, the rated current and the tripping characteristic against your distribution board, then send us the quantity and the delivery location for a quotation.

Seven Star LLC supplies ABB low-voltage protection devices in Oman and the GCC. Share your board schedule and we will match the breakers, the accessories and the busbars.

Other Models in the Abb Sh200 Mcb Range

Seven Star LLC supplies models from the Abb Sh200 Mcb range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ABB SH201-C16 1P MCB 16 A C Curve, SH200Circuit BreakersYou are viewing this model
ABB SH203-C16 3P MCB 16 A C Curve, SH200Circuit BreakersView details
ABB SH203-C32 3P MCB 32 A C Curve, SH200Circuit BreakersView details
Datasheets & Documents
  • PDF Datasheet ABB Compact Home Catalogue, SH 200 MCB Section (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.

ABB company profile

Formed 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50%
ASEA Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators
Brown, Boveri & Cie Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri
Headquarters Zurich, Switzerland; ABB Ltd became the group holding company in 1999
Ownership Public company listed on SIX Swiss Exchange and Nasdaq Stockholm
Brands in the group Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers
Product families Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots

Milestones

  • 1883: ASEA is founded in Västerås, Sweden.
  • 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
  • 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
  • 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
  • 2011 and 2017: Baldor Electric and B&R join ABB.
  • 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.

Choosing an ABB drive

ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.

Where ABB products are used

In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.

ABB products we list

Family Examples
AC drives ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module
Breakers, motor control and protection SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay
Flow measurement ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500
Pressure, temperature and level 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge
Analysers Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210
Control systems and actuators AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000

Ordering ABB products: what we need

Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.

Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.

Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.

FAQ

Questions about the ABB SH201-C16 1P MCB 16 A C Curve, SH200

Answers from our engineering team on installation, compatibility and integration.

01What is the rated current of the SH201-C16?
The SH201-C16 is rated 16 A with a C tripping characteristic. It is a 1P miniature circuit breaker, so the pole count must match the circuit it protects.
02What is the short-circuit capacity of the SH201-C16?
The ABB data lists a rated short-circuit capacity of 6 kA AC. Compare this with the prospective short-circuit current at the board before you rely on the device.
03Can I fit accessories to the SH201-C16?
ABB lists no accessories as available for this type of the Compact Home series. If remote signalling is needed, choose a type from a series that supports accessories.
04What DIN rail width does the SH201-C16 need?
The ABB data lists a width of 17.5 mm, a height of 85 mm and a depth of 69 mm. It clips on a 35 mm DIN rail.
05What does the C characteristic of the SH201-C16 mean?
The C characteristic is a general-purpose curve in which the electromagnetic release acts at five to ten times the rated current in line with IEC/EN 60898-1. It suits lighting, sockets and small motor loads.