Brand: ABB
ABB VD4/P 12.12.40 Vacuum Circuit Breaker
Description
Overview
The ABB VD4/P 12.12.40 is a compact, withdrawable medium-voltage vacuum circuit breaker from ABB’s VD4 platform, purpose-built for outgoing feeder, motor, and transformer feeder protection at 1250A. Rated at 12kV with a short-circuit breaking current of 40kA, this variant delivers the same high fault-clearing capability as the higher-current VD4/P models while operating comfortably under natural air cooling, since 1250A does not need the forced ventilation that ABB specifies for the 4000A rating.
Backed by manufacturer datasheet documentation, Seven Star LLC proudly supplies the ABB VD4/P 12.12.40 to industrial feeder panels, motor control switchboards, and distribution substations across the Sultanate of Oman, Muscat, and the wider GCC. Panel builders and plant electrical engineers specifying individual feeder or motor circuits within a multi-bay switchgear lineup rely on this breaker for its combination of compact truck dimensions, proven vacuum interruption, and full interchangeability with ABB’s standardized withdrawable switchgear cubicles.
Operating Principle
The ABB VD4/P 12.12.40 clears fault and load current through vacuum interrupters embedded in resin-moulded poles, the same patented ABB construction used across the entire VD4 range. As the moving contact separates from the fixed contact inside the sealed vacuum envelope, a brief metal-vapor arc is drawn and self-extinguishes at the first natural current zero, since there is no gas or oil medium present to sustain re-ignition. Dielectric strength across the open gap recovers within microseconds, giving the breaker outstanding performance against transient recovery voltage even at its full 40kA rating.
Because the 1250A rating keeps conductor and contact heating well within natural convection limits, the ABB VD4/P 12.12.40 requires no forced-air cooling module, simplifying the truck design and reducing auxiliary power requirements compared with the higher-current VD4/P variants. The vacuum interruption principle itself remains free of arc byproducts, oxidation, or gas depletion, so contact wear stays minimal across thousands of feeder switching operations and the breaker requires virtually no interrupter maintenance throughout its service life.
Engineering Design of the ABB VD4/P 12.12.40
The physical architecture of the ABB VD4/P 12.12.40 uses the same withdrawable truck platform as the wider VD4/P family, sliding into fixed switchgear cubicles and automatically engaging primary disconnecting contacts, secondary control plugs, and safety shutters as the truck is racked between test, disconnected, and service positions. The three vacuum poles are cast in glass-fiber reinforced epoxy resin, protecting the interrupter from dust, humidity, and mechanical shock while preserving dielectric performance across the full withdrawable lifespan.
Switching is performed by ABB’s stored-energy spring mechanism, motor-charged for automatic reset and delivering the rated operating sequence O-0.3s-CO-15s-CO independent of manual operating speed. The front fascia includes mechanical spring-charge and position indicators, open/close pushbuttons, an operation counter, and terminal blocks for auxiliary contacts, under-voltage release, and interfacing with feeder protection relays such as ABB REF542plus, making the breaker straightforward to commission into automated feeder and motor protection schemes.
Key Features
Specifying the ABB VD4/P 12.12.40 for feeder or motor protection bays gives engineers a proven, compact vacuum breaker with strong fault-clearing margin. Core capabilities include:
- Rated normal current of 1250A suited to individual feeder, motor, and transformer feeder circuits without requiring forced-air cooling.
- Rated short-circuit breaking capacity of 40kA, matching the fault-clearing performance of higher-current VD4/P variants.
- Vacuum interrupters embedded in resin-moulded poles for decades of maintenance-free dielectric integrity.
- Compact withdrawable truck construction enabling safe isolation and rapid breaker exchange without de-energizing adjacent feeder bays.
- ABB stored-energy spring operating mechanism for the rated O-0.3s-CO-15s-CO operating sequence.
- Full compliance with IEC 62271-100 and IEC 62271-1 for global interchangeability with modern MV switchgear.
- Auxiliary contacts and under-voltage release terminals for direct integration with feeder and motor protection relays.
- Withdrawable VD4/P version designed for ABB UniGear ZS1 switchgear.
Applications
The 1250A rating of the ABB VD4/P 12.12.40 makes it the standard choice for individual outgoing feeder circuits, medium-voltage motor starters, and transformer feeder positions in industrial switchgear lineups across Oman, including oil and gas production facilities, desalination plants, cement works, and large commercial developments where dozens of feeder breakers may share a single busbar fed by a higher-rated incomer. Its compact truck footprint allows dense feeder bay arrangements without compromising the 40kA fault-clearing capability the switchgear design requires.
Working closely with plant engineers in the region, Seven Star LLC distributes the ABB VD4/P 12.12.40 to panel builders, contractors, and plant operators across the Sohar and Salalah economic zones, supporting new switchgear projects as well as breaker replacement and retrofit programs on aging feeder panels. The breaker’s compatibility with ABB’s standardized withdrawable envelope simplifies spare-parts holding for sites operating multiple VD4/P current ratings side by side.
Technical Specifications
Full technical parameters for the ABB VD4/P 12.12.40 medium-voltage vacuum circuit breaker:
| Parameter | Specification |
|---|---|
| Model | ABB VD4/P 12.12.40 |
| Rated Voltage | 12kV |
| Rated Frequency | 50/60Hz |
| Rated Normal Current | 1250A (natural air cooled) |
| Rated Short-Circuit Breaking Current | 40kA |
| Rated Short-Time Withstand Current | 40kA for 3s |
| Rated Peak Withstand (Making) Current | 100kA |
| Rated Lightning Impulse Withstand Voltage | 75kV |
| Operating Mechanism | Stored-energy spring type, motorized |
| Operation Sequence | O-0.3s-CO-15s-CO |
| Type | Withdrawable (Plug-in Truck), 3-Pole |
| Applicable Standard | IEC 62271-100, IEC 62271-1 |
Request a Quote for ABB VD4/P 12.12.40 Vacuum Circuit Breaker
To submit a formal Request for Quote (RFQ), confirm current availability and lead time, or download the complete technical datasheet for the ABB VD4/P 12.12.40 vacuum circuit breaker, contact the instrumentation and electrical apparatus division at Seven Star LLC today. Our team can support feeder and motor protection panel design and retrofit sourcing, with the lead time confirmed at quotation.
Other Models in the ABB VD4/P Vacuum Circuit Breakers Range
Seven Star LLC supplies models from the ABB VD4/P Vacuum Circuit Breakers range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB VD4/P 12.06.32 Medium Voltage Vacuum Circuit Breaker – 12kV, 630A, 31.5kA | Circuit Breakers | View details |
| ABB VD4/P 12.12.25 Vacuum Circuit Breaker | Circuit Breakers | View details |
| ABB VD4/P 12.40.40 Vacuum Circuit Breaker | Circuit Breakers | View details |
| ABB VD4/P 12.12.40 Vacuum Circuit Breaker | Circuit Breakers | You are viewing this model |
| ABB VD4/P 12.20.40 Vacuum Circuit Breaker | Circuit Breakers | View details |
Related Products
- Schneider Electric Compact NSX MicroLogic Trip Unit
- Schneider Electric EasyPact TVS Vacuum Circuit Breaker
- Schneider Electric Acti9 iATL Automatic Transfer Switch
- Schneider Electric Compact NS1600 Air Circuit Breaker
- Schneider Electric ComPacT NSX Communicating Circuit Breaker
- ABB VD4/P 12.06.32 Medium Voltage Vacuum Circuit Breaker – 12kV, 630A, 31.5kA
- Legrand DX3 C32 4-Pole Miniature Circuit Breaker
- Hubbell HBL4100P6W IEC Pin and Sleeve Plug
Datasheets & Documents
- Instruction Manual ABB VD4/P Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB, formed in 1988 and headquartered in Zurich, covers an unusually long stretch of a plant's equipment list, from the flowmeter and analyzer in the field to the drive, breaker and protection relay in the electrical room.
Seven Star LLC is an independent supplier serving Oman and the GCC. Our ABB listing concentrates on measurement and analytics: ABB flowmeters, liquid analysis sensors and systems, level and pressure instruments. It also includes valve actuators, low voltage circuit breakers, ABB drives, soft starters and protection relays.
ABB product families on this page
Flow measurement includes ABB electromagnetic, Coriolis, vortex and swirl meters, sold under names such as ProcessMaster, AquaMaster, CoriolisMaster and SwirlMaster. Liquid analysis covers pH, conductivity and dissolved oxygen sensors with their transmitters. SensyTemp TSP sensors handle temperature. On the electrical side the listing has ACS355 machinery drives, the ACS550 general purpose drive, the ACQ580 for water and wastewater and the ACS880-01 industrial drive, with fieldbus adapters such as the FPBA-01 for PROFIBUS DP. Protection and switching products include SACE Tmax XT molded case breakers, SACE Emax 2 air circuit breakers, PSR soft starters and the REM615 and RET615 relays.
Where ABB instruments and drives are used
Water and wastewater plants use the electromagnetic flowmeters, analyzers and ACQ580 drives together. Oil and gas, power and chemical plants specify the Coriolis and vortex meters, pressure and level transmitters and the 615 series relays for motor and transformer feeders. The drives run pumps, fans, conveyors and compressors in almost every industry.
Ordering ABB parts: what we need
For drives send the full type code from the rating label, for example ACS355-03E-05A6-4, plus the serial number if it is a replacement. For instruments send the complete order code, measuring span, process connection, wetted materials, output or protocol and the hazardous area approval. For breakers give frame size, rated current, breaking capacity, number of poles, trip unit and fixed or withdrawable version.
Related products
Frequently Asked Questions
The ABB VD4/P 12.12.40 is rated 1250A and 40kA, making it the standard choice for individual outgoing feeder, motor, and transformer feeder circuits within a medium-voltage switchgear lineup rather than main incomer duty.
No. At 1250A the conductor and contact heating stays within natural convection limits, so the VD4/P 12.12.40 uses natural air cooling and does not require the forced ventilation used for the 4000A rating.
Yes. This is the typical switchgear arrangement, with several 1250A feeder breakers connected to a busbar fed by a single higher-current incomer breaker such as the VD4/P 12.40.40 or 12.20.40.
Yes. Auxiliary contacts and under-voltage release terminals allow direct wiring to feeder protection and control relays such as the ABB REF542plus for automated tripping and SCADA integration.
Yes, Seven Star LLC is an experienced supply partner for ABB. Seven Star LLC supplies ABB products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.