- Automation & ControlView all 2,607 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ABB
ABB S201-C80 S200 MCB 80 A Curve C, single pole
Description
S201-C80 80 A curve C single-pole breaker decoded
The ABB S201-C80 is a single-pole miniature circuit breaker with a 80 A rated current and C characteristic from the System pro M compact S200 family. The 80 A and 100 A ratings extend the range to higher currents while keeping the one-module-per-pole width of 17.5 mm. The ABB order code is 2CDS251001R0804 and the EAN is 4016779916509.
Reading the type name: S201 gives the pole count (1), C the tripping characteristic, and 80 the rated current in amperes. The C characteristic trips between 5 and 10 times In; this makes the S201-C80 well suited to general distribution, lighting and mixed motor-and-socket circuits.
S201-C80 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | ABB / S201-C80 |
| Order code | 2CDS251001R0804 |
| EAN | 4016779916509 |
| Series | System pro M compact S200, 80 A to 100 A range |
| Poles | 1 |
| Tripping characteristic | C |
| Rated current In | 80 A |
| Standards | IEC/EN 60898-1, IEC/EN 60947-2 |
| Rated operational voltage Un (IEC/EN 60898-1) | 230/400 V AC |
| Rated frequency | 50/60 Hz |
| Rated short-circuit capacity Icn | 6 kA |
| Icu / Ics (IEC/EN 60947-2) | 6 kA / 6 kA |
| Rated insulation voltage Ui | 440 V AC |
| Rated impulse withstand voltage Uimp | 4 kV (1.2/50 µs) |
| Thermal release | 1.13 × In non-tripping, 1.45 × In tripping within 2 h |
| Magnetic release | 400 to 800 A (5 to 10 × In) |
| Terminals | Failsafe bi-directional cage clamp, up to 50 mm² solid, stranded and flexible, 3.0 Nm |
| Pole dimensions (H × D × W) | 88.8 × 69 × 17.5 mm per pole |
| Weight (pack of 10: per piece) | 0.128 kg |
| Ambient / storage temperature | −25 to +55 °C / −40 to +70 °C |
| Endurance | 10,000 electrical / 20,000 mechanical operations |
| Protection degree | IP20, IP40 in an enclosure with cover |
| Mounting | 35 mm DIN rail by fast clip, any position, any supply |
How the S201-C80 trips
A bimetal element opens the contacts on sustained overload: up to 1.13 times In the breaker must hold for at least two hours, and at 1.45 times In it must open within two hours. A magnetic element covers short circuits and acts between 400 to 800 A (5 to 10 × In) on AC without intentional delay.
The thermal element is calibrated for a 30 °C reference temperature (55 °C under IEC/EN 60947-2 reference conditions). In warmer cabinets the usable current drops by roughly 6 % for every 10 K of temperature rise, so a 80 A rating inside a hot enclosure behaves like a smaller breaker.
Derating the 80 A single-pole in a hot panel
Derating matters most at this rating. With the cabinet at 40 °C the allowable current falls by about 6 %, at 50 °C by about 12 %, and when several breakers sit side by side with load on all poles the grouping correction factor reduces the limit further. Spacing the breakers or using a ventilated enclosure helps. For the S201-C80, check the manufacturer derating table for the exact figures before finalising the cable and breaker size.
Where the S201-C80 fits and related parts
The S201-C80 works with the S2C accessory family: the auxiliary contact S2C-H6R, the signal and auxiliary contact S2C-S/H6R, the shunt trip S2C-A, the undervoltage release S2C-UA and the overvoltage release S2C-OVP. Alongside the breakers of the same range (S201, S202, S203 and S204, curves B and C, 80 A and 100 A) there are NA versions with a neutral pole. On the same rail you will often see S201-C80 or S203-C100 next to the S201-C80, depending on the pole count of each feeder.
S201-C80 and sibling order codes
| Type | Order code | Packing unit | Weight per piece |
|---|---|---|---|
| S201-B100 | 2CDS251001R0825 | 10 | 0.128 kg |
| S201-B80 | 2CDS251001R0805 | 10 | 0.128 kg |
| S201-C100 | 2CDS251001R0824 | 10 | 0.128 kg |
| S201-C80 | 2CDS251001R0804 | 10 | 0.128 kg |
| S202-C80 | 2CDS252001R0804 | 5 | 0.256 kg |
| S203-C80 | 2CDS253001R0804 | 1 | 0.384 kg |
Selection checklist for the S201-C80
- Rated current 80 A against load, cable cross-section (terminals take up to 50 mm²) and cabinet temperature
- Curve C against the inrush of the connected load
- 1 pole(s) against the system: one phase conductor of a 230 V or 230/400 V system
- Prospective short-circuit current at the board, which must not exceed 6 kA
- Accessories: auxiliary contact, trips, motor operating device
Installing the S201-C80
Snap the breaker on to a 35 mm DIN rail with the fast clip. Strip the conductor, insert it into the cage clamp with the screw loose, and tighten to 3.0 Nm with a Pozidriv 2 driver. The toggle is sealable and shows the contact position in red for ON and green for OFF. Supply can be fed from either side. After commissioning, retighten the terminals once the load has cycled, because large conductors at 80 A and 100 A can settle.
Using the S201-C80 in Oman and the GCC
For electrical rooms with high ambient temperature, the 55 °C rating and cyclic damp-heat test are useful. The S201-C80 80 A C breaker is used as a sub-distribution feeder in buildings, workshops, pump houses and utility rooms in oil and gas, power, desalination and petrochemical sites, wherever a compact 6 kA breaker at this rating is enough. Where the prospective fault level is higher, a step up to the S800 range should be considered.
Information to send with an RFQ for the S201-C80
- Full type name S201-C80 and order code 2CDS251001R0804
- Quantity and any accessories
- System voltage and prospective short-circuit current
- Load type and ambient temperature in the panel
- Delivery location in Oman or the GCC
Storage, handling and spares for the ABB S201-C80
Keep ABB S201-C80 units in their original packaging until they are mounted. Store them indoors in a dry, dust-free room, away from direct sun and condensation. Panel shops in Oman and the GCC often hold stock in warehouses that get very hot in summer, so check that storage temperature stays within the limits given in the manufacturer datasheet.
- Check the label and order code on every unit against the drawing before it goes into the panel.
- Use the correct tool and tightening torque for the terminals, as given in the instructions supplied with the product.
- Keep a small number of spare units for each rating used on site, so that a failed or damaged part can be replaced without waiting for a new shipment.
- Record the order code in the panel documentation and the as-built drawings, so that maintenance teams can reorder the same part later.
When you plan spares for a project, group the ABB S201-C80 with the other parts of the same panel in one RFQ. This keeps delivery dates aligned and makes it easier to confirm stock for the whole bill of materials at once.
Documents and quotation
The official ABB data sheet for the System pro M compact S 200 80A-100A miniature circuit breakers (2CDC002180D0203, English) is attached on this page as a PDF and covers the ABB S201-C80 order number. It lists the 80 A and 100 A ratings in B and C characteristic, the rated breaking capacity to IEC/EN 60898-1 and IEC/EN 60947-2, the tripping curves, the terminal capacity, the dimensions and the compatible accessories. Check the rated current, the number of poles and the short-circuit level at your installation point before ordering, then send us the quantity and the delivery location for a quotation.
Seven Star LLC supplies ABB low-voltage protection in Oman and the GCC from Muscat.
Other Models in the Abb S200 80 100a C Range
Seven Star LLC supplies models from the Abb S200 80 100a C range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB S201-C80 S200 MCB 80 A Curve C, single pole | Circuit Breakers | You are viewing this model |
| ABB S201-C100 S200 MCB 100 A Curve C, single pole | Circuit Breakers | View details |
| ABB S203-C80 S200 MCB 80 A Curve C, three pole | Circuit Breakers | View details |
| ABB S203-C100 S200 MCB 100 A Curve C, three pole | Circuit Breakers | View details |
| ABB S204-C80 S200 MCB 80 A Curve C, four pole | Circuit Breakers | View details |
| ABB S204-C100 S200 MCB 100 A Curve C, four pole | Circuit Breakers | View details |
Datasheets & Documents
- Datasheet ABB S 200 80A-100A Miniature Circuit Breaker Data Sheet 2CDC002180D0203 (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB S201-C80 S200 MCB 80 A Curve C, single pole
Answers from our engineering team on installation, compatibility and integration.
01What is the ABB S201-C80?
It is a single-pole S200 miniature circuit breaker rated 80 A with C characteristic, approved to IEC/EN 60898-1 and IEC/EN 60947-2, with a breaking capacity of 6 kA.
02What is the magnetic trip range of the S201-C80?
The instantaneous release operates between 400 to 800 A (5 to 10 x In) on AC; the thermal release holds 1.13 times In and trips at 1.45 times In.
03How wide is the S201-C80?
Each pole is 17.5 mm wide, so the S201-C80 occupies 17.5 mm of rail. Height is 88.8 mm and depth 69 mm.
04Which conductor size does the S201-C80 accept?
The failsafe bi-directional cage clamp accepts up to 50 mm2 solid, stranded or flexible conductors, tightened to 3.0 Nm with a Pozidriv 2 driver.
05Does ambient temperature affect the S201-C80?
Yes. The breaker is calibrated at 30 deg C and the allowable current falls by about 6 percent for each 10 K rise; it is rated for operation from minus 25 to plus 55 deg C.


















Reviews
There are no reviews yet.