Hanna HI97700 Ammonia Low Range Photometer 0-3 mg/L

Description

Hanna HI97700 Ammonia low range portable photometer

The Hanna HI97700 is a pocket-sized, single-parameter photometer built for trace ammonia checks on process water, boiler feed and effluent samples. It covers 0.00 to 3.00 mg/L ammonia nitrogen with 0.01 mg/L resolution, which suits polishing-stage and receiving-water checks where values stay low. The display can switch between ammonia nitrogen and the NH3 or NH4+ forms. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we quote the HI97700 to industrial and laboratory buyers across Oman and the GCC.

The model number follows Hanna’s HI977xx pattern for dedicated photometers: the last digits identify the chemistry, so HI97700 always means ammonia low range and cannot be reconfigured for another analyte. Reagents carry their own HI93xxx codes, listed below, and must be ordered separately from the meter.

HI97700 technical specifications

Parameter Specification
Manufacturer / part number Hanna Instruments HI97700
Parameter Ammonia low range
Range 0.00 to 3.00 mg/L as NH3-N
Resolution 0.01 mg/L
Accuracy at 25 °C ±0.04 mg/L ±4 % of reading
Method Adaptation of ASTM D1426 Nessler method
Light source LED with narrow-band interference filter at 420 nm
Filter bandwidth / wavelength accuracy 8 nm / ±1.0 nm
Detector Silicon photocell
Cuvette Round, 24.6 mm diameter (22 mm inside)
Data logging 50 readings (auto logging)
Display 128 × 64 pixel monochrome LCD with backlight
Power Three 1.5 V AA alkaline batteries; more than 800 measurements without backlight
Operating environment 0 to 50 °C; 0 to 100 % RH
Ingress protection IP67, floating case
Dimensions / weight 142.5 × 102.5 × 50.5 mm / 380 g with batteries
Warranty Two years

How the HI97700 measurement works

Ammonia reacts with the Nessler reagent to form a yellow-brown compound. The depth of colour is proportional to ammonia concentration, and the meter reads absorbance at 420 nm against an unreacted blank of the same sample, then converts it to mg/L using the Lambert-Beer relationship.

Inside the case a reference detector tracks the LED output, so battery sag or a warm ambient does not move the blank. A lens gathers the light leaving the cuvette, which is why scratches and small glass imperfections matter less than with a simple colorimeter, and the cap notch locks the cuvette in the same orientation every time. A built-in tutorial mode walks the operator through sampling, reagent quantity and timers on screen, so the instrument can be handed to a technician who is not a chemist.

Reagents, procedure and interferences for HI97700

The test uses a 10 mL sample, two liquid reagents added drop-wise, and a 3 minute 30 second countdown that the operator can skip by pressing Read twice if the sample was already prepared.

Code Description Quantity per test
HI93700A-0 Ammonia LR Reagent A 4 drops
HI93700B-0 Ammonia LR Reagent B 4 drops

Reagent sets are supplied as HI93700-01 (100 tests) and HI93700-03 (300 tests). Follow the zeroing order given in the manual for this method, and read within the time the manual allows after the countdown ends.

Known interferences listed for this method:

  • Hardness above 1 g/L
  • Iron
  • Sulfide, which can cause turbidity
  • Organics such as acetone above 0.1 %, alcohols, aldehydes, aliphatic and aromatic amines, chloramines, glycine and urea above 10 mg/L; distillation is needed to remove them

Where the HI97700 sits among Hanna photometers

Choose the low-range model when typical readings are below about 3 mg/L. The medium-range HI97715 reaches 10.00 mg/L and the high-range HI97733 reaches 100.0 mg/L as NH4+; all three use the same Nessler chemistry family and 420 nm LED, so one technician can run any of them with the same handling habits.

Model Parameter Range LED filter
HI97700 Ammonia low range 0.00 to 3.00 mg/L as NH3-N 420 nm
HI97715 Ammonia medium range 0.00 to 10.00 mg/L as NH3-N 420 nm
HI97733 Ammonia high range 0.0 to 100.0 mg/L as NH4+ 420 nm
HI97701 Free chlorine 0.00 to 5.00 mg/L as Cl2 525 nm
HI97762 Free chlorine ultra low range 0.000 to 0.500 mg/L as Cl2 525 nm
HI97734 Free and total chlorine, high range 0.00 to 10.00 mg/L as Cl2 525 nm
HI97725 Chlorine, cyanuric acid and pH 0.00 to 5.00 mg/L Cl2; 0 to 80 mg/L CYA; 6.5 to 8.5 pH 525 nm
HI97706 Phosphorus 0.0 to 15.0 mg/L as P 525 nm
HI97714 Cyanide 0.000 to 0.200 mg/L as CN– 610 nm
HI97718 Iodine 0.0 to 12.5 mg/L as I2 525 nm
HI97731 Zinc 0.00 to 3.00 mg/L as Zn 575 nm
HI97737 Silver 0.000 to 1.000 mg/L as Ag 575 nm

Selection and ordering checklist for HI97700

  • Confirm expected ammonia concentration stays inside 0.00 to 3.00 mg/L; otherwise dilute or use HI97715 or HI97733
  • Decide whether results should be reported as NH3-N, NH3 or NH4+
  • Order HI93700-01 or HI93700-03 reagent sets; they are not included with the meter
  • Add HI97700-11 CAL Check cuvettes if periodic performance validation is required
  • Check the sample for the interferences listed above before relying on a result

Validation, handling and maintenance of HI97700

The CAL Check function lets the operator verify the optical system with NIST-traceable cuvettes (HI97700-11) at any time and apply a user calibration if the reading drifts. GLP information is stored with the meter, and the last 50 readings can be reviewed on screen.

Keep cuvettes clean with the cleaning solution and a lint-free cloth, never touch the lower half of the glass, and store the meter in its carrying case. Replace the three AA cells when the battery icon appears; the meter keeps its logged readings and settings. For long storage between field trips remove the batteries and close the reagent bottles tightly.

Typical applications of HI97700 in Oman and the GCC

In desalination plants the HI97700 is a quick way to confirm ammonia carry-over in permeate or in chlorination-dechlorination steps. Power stations use it on cycle chemistry samples, municipal and industrial wastewater operators in Oman use it to check nitrification performance, and oil and gas sites use it on produced-water treatment and discharge compliance spot checks.

Heat is a practical factor in the Gulf. Reaction times in the manual are given at 25 °C, so samples that sit in a vehicle at much higher temperature should be allowed to equilibrate, and the meter itself is rated for 0 to 50 °C. The sealed optics and IP67 floating case also cope with dust and spray on plant walkdowns.

Information to send with an RFQ for HI97700

  • Quantity of meters and whether reagent sets (HI93700-01 or HI93700-03; CAL Check HI97700-11) and CAL Check cuvettes are also required
  • Sample matrix and expected concentration, so we can confirm the range suits the application
  • Delivery location in Oman or the GCC and required lead time
  • Any need for spare cuvettes, carrying case or cleaning solution
  • Project or tender reference, if applicable

Documents and quotation

The instruction manual for the HI97700 is attached on this page and covers specifications, the reagent procedure, CAL Check validation and error messages.

Send the part number HI97700, the quantity and your delivery location and we will reply with availability and a quotation.

Other Models in the Hanna Hi977xx Photometer Range

Seven Star LLC supplies models from the Hanna Hi977xx Photometer range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hanna HI97700 Ammonia Low Range Photometer 0-3 mg/LLiquid Analytical SystemsYou are viewing this model
Hanna HI97715 Ammonia Medium Range Photometer 0-10 mg/LLiquid Analytical SystemsView details
Datasheets & Documents
  • PDF Manual Hanna HI97700 Instruction Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.

Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.

Hanna Instruments company profile

Founded 1978, near Padua, Italy, by Oscar and Anna Nardo
Headquarters Woonsocket, Rhode Island, USA
Leadership Martino Nardo and Pamela Nardo
Early product The pHep pocket pH tester
Product families pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers

Hanna product series

Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.

The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.

Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.

Where Hanna instruments are used

Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.

Hanna Instruments products we list

Family Examples
Portable Test & Measurement Hanna HI97711 Free and Total Chlorine Po…, Hanna HI98190 Waterproof Portable pH and…, Hanna HI98192 Waterproof Portable EC, Hanna HI98193 Waterproof Portable Dissol…, Hanna HI98199 Portable pH, Hanna HI9829 Multiparameter Water Qualit…, Hanna HI98703 Portable Turbidity Meter

Ordering Hanna instruments: what we need

Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.

Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.

FAQ

Questions about the Hanna HI97700 Ammonia Low Range Photometer 0-3 mg/L

Answers from our engineering team on installation, compatibility and integration.

01What does the HI97700 measure and in what range?
It measures ammonia in water from 0.00 to 3.00 mg/L as ammonia nitrogen with 0.01 mg/L resolution, using an adaptation of the ASTM D1426 Nessler method at 420 nm.
02Are reagents included with the HI97700?
No. The meter is a dedicated reader; Ammonia LR reagent sets HI93700-01 (100 tests) or HI93700-03 (300 tests) are ordered separately.
03How long does one test take?
After zeroing on the unreacted sample and adding both reagents, the meter counts down 3 minutes 30 seconds before reading. The timer can be skipped by pressing Read twice.
04Can the result be shown as ammonium instead of ammonia nitrogen?
Yes. The chemical form setting lets the display switch from NH3-N to mg/L of ammonia or ammonium, so the same reading can be reported in the unit your procedure requires.
05How do I confirm the meter is still accurate?
Use the CAL Check function with the HI97700-11 cuvette kit. It validates the optics against NIST-traceable standards and allows a user calibration if needed.