- Automation & ControlView all 2,317 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Hanna Instruments
Hanna HI6221 Advanced Benchtop pH/ORP Meter, 5-Point Cal
Description
Hanna HI6221 advanced benchtop pH/ORP meter
The Hanna HI6221 is a laboratory benchtop pH and ORP meter with selectable resolution down to 0.001 pH, five-point calibration and a temperature input for automatic compensation. It is supplied as a starter kit with an HI1131B glass-body pH electrode and an HI7662-TW temperature probe. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
The part number is the instrument itself; the kit adds an electrode holder, buffer sachets, cleaning solution, 3.5 M KCl electrolyte, a capillary pipette, a 24 VDC power adapter and a USB-C cable.
HI6221 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Hanna Instruments HI6221 |
| pH range | -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH |
| pH resolution | 0.1 pH; 0.01 pH; 0.001 pH |
| pH accuracy at 25 °C | ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) |
| pH calibration | Automatic, semi-automatic or manual, up to five points; eight standard buffers (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and five custom buffers |
| Temperature compensation | Manual or automatic |
| Temperature | -20.0 to 120.0 °C (-4.0 to 248.0 °F, 253.0 to 393.0 K); resolution 0.1; accuracy ±0.2 °C |
| pH electrode / probe | HI1131B glass-body electrode; HI7662-TW stainless-steel temperature probe |
| Power | DC adapter 100-240 VAC to 24 VDC, 2.5 A |
| Environment | 0 to 50 °C; up to 95 % RH non-condensing |
| Size / weight | 205 × 160 × 77 mm; about 1.2 kg |
| Warranty | Two years |
How the HI6221 works
A glass pH electrode produces a potential that depends on hydrogen-ion activity; the HI6221 measures it with a high-impedance input, applies the slope and offset from calibration and corrects for temperature. In ORP mode the same electrode input is used with a redox sensor and reads relative millivolts.
Calibration is the real strength of the instrument. With up to five points from eight standard buffers or five user buffers, the operator can bracket a narrow production range or span acid to alkaline solutions. Choosing the lowest resolution suits routine control; the 0.001 pH setting is for work where the electrode and sample warrant it.
Where HI6221 fits: sensors, accessories and related models
The HI1131B electrode and HI7662-TW temperature probe are supplied. The calibration starter kit includes pH 4.01 (two sachets), 7.01 (four) and 10.01 (two) buffers, HI700601 cleaning solution, HI7082 3.5 M KCl electrolyte, an HI764060 electrode holder and a capillary pipette. USB-C connectivity moves the meter into a laboratory data workflow.
Portable users should look at the HI8424 for field work; the HI6221 is for the bench.
HI6221 family comparison
| Model | Format | pH range | Best accuracy |
|---|---|---|---|
| HI8424 | Portable | -2.00 to 16.00 pH | ±0.01 pH |
| HI6221 | Benchtop | -2.000 to 20.000 pH | ±0.002 pH |
Pick the HI6221 for quality-control and research benches, the HI8424 for plant walks, and a multiparameter meter such as the HI98195 for sampling across sites.
Selection and ordering checklist for HI6221
- Decide on resolution: 0.1, 0.01 or 0.001 pH
- Confirm the buffer set matches your calibration range (eight standards plus five custom)
- Check electrode suitability for your samples; other Hanna electrodes may fit better for viscous or non-aqueous samples
- Plan spare electrodes, KCl electrolyte and buffers
- Confirm USB-C data export and power adapter requirements
Installation, calibration and maintenance of HI6221
Place the meter on a stable bench away from stirrers that heat the sample, fill the electrode with electrolyte if refillable as directed, and soak it in storage solution before first use. Calibrate with fresh buffers that bracket the sample, using at least two points and more if the application demands.
Rinse the electrode between samples, avoid touching the glass bulb and keep the electrolyte level topped up. Clean with the HI700601 solution when the slope falls, and replace the electrode when calibration slope or response time can no longer be restored.
A good laboratory routine records the buffer lots, calibration points and electrode serial in a log, and verifies the calibration with a check buffer during long sessions. When measuring at different temperatures, allow samples and buffers to equilibrate and keep the temperature probe in the sample so that compensation is genuine.
If the same bench is shared between technicians, define one standard calibration recipe so that results from different users are comparable.
Electrode care deserves a short written routine. After each session, rinse the bulb with deionised water, return the electrode to storage solution and never to deionised water, and check the electrolyte level. Once a month, inspect the junction, clean it with the cleaning solution if sluggish, and compare the response against a fresh pH 7.01 buffer. Keeping a spare electrode in the drawer means a failed sensor does not stop the laboratory, and a record of calibration slopes gives early warning of ageing before results are affected. When the meter is moved between benches, recheck that the temperature probe and electrode connectors are fully seated before calibrating again.
Typical applications of HI6221 in Oman and the GCC
In Oman the HI6221 suits quality-control laboratories at refineries, petrochemical and power plants, desalination laboratories verifying permeate and chemical dosing, environmental testing laboratories and university benches. Its high ceiling of 20 pH and low floor of -2 pH covers strongly alkaline cleaning solutions and acid regeneration liquors.
Laboratories that audit contractors or compare against field meters often keep a benchtop unit as the local reference, which is where five-point calibration earns its place.
Information to send with an RFQ for HI6221
- Quantity and any spare electrodes or temperature probes
- Buffers, electrolyte and cleaning solutions needed
- Sample type and temperature range
- Delivery location and lead time
- Project or tender reference
Documents and quotation
The instruction manual for the HI6221 is attached on this page for specifications, calibration procedures and maintenance steps.
Send the part number HI6221, the quantity and your delivery location and we will reply with availability and a quotation.
Other Models in the Hanna Ph Meter Range
Seven Star LLC supplies models from the Hanna Ph Meter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Hanna HI8424 Portable pH/mV Meter with Temperature Probe | Liquid Analytical Systems | View details |
| Hanna HI6221 Advanced Benchtop pH/ORP Meter, 5-Point Cal | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Manual Hanna HI6221 Instruction Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.
Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.
Hanna Instruments company profile
| Founded | 1978, near Padua, Italy, by Oscar and Anna Nardo |
|---|---|
| Headquarters | Woonsocket, Rhode Island, USA |
| Leadership | Martino Nardo and Pamela Nardo |
| Early product | The pHep pocket pH tester |
| Product families | pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers |
Hanna product series
Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.
The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.
Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.
Where Hanna instruments are used
Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.
Hanna Instruments products we list
Ordering Hanna instruments: what we need
Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.
Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.
Browse Hanna Instruments products by category: Portable Test & Measurement.
FAQ
Questions about the Hanna HI6221 Advanced Benchtop pH/ORP Meter,
Answers from our engineering team on installation, compatibility and integration.
01What resolution does the HI6221 offer?
The user can select 0.1, 0.01 or 0.001 pH, with accuracies of 0.1, 0.01 and 0.002 pH respectively at 25 degrees C.
02How many calibration points are supported?
Up to five points, using eight standard buffers (1.68 to 12.45 pH) or five custom buffers, in automatic, semi-automatic or manual mode.
03What is included in the kit?
HI1131B pH electrode, HI7662-TW temperature probe, buffer and cleaning sachets, 3.5 M KCl electrolyte, electrode holder, capillary pipette, power adapter and USB-C cable.
04Can it measure ORP?
Yes, it is an advanced pH/ORP meter; ORP is read with a redox electrode connected to the input.
05What is the temperature range?
-20.0 to 120.0 degrees C with 0.1 resolution and accuracy of 0.2 degrees C, with manual or automatic pH temperature compensation.


















Reviews
There are no reviews yet.