- Automation & ControlView all 2,254 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Industrial Computers
- Servo Drives
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric GVAD1010 TeSys GV2/GV3 2 NO Contact Block
Description
GVAD1010: two normally open contacts for breaker status and trip signals
The GVAD1010 is a Schneider Electric TeSys Deca side contact block for GV2 and GV3 motor circuit-breakers with two normally open contacts, one of which acts as the fault signal. It is the right accessory when the control system only needs closing signals and no normally closed loop. Seven Star LLC supplies the GVAD1010 in Oman and the GCC as an independent supplier based in Muscat.
Within the family, the GVAD1010 is the only active reference with two NO contacts. The other three trade one of them for a normally closed contact. So the choice is mostly about the input card that will read them.
Technical specifications of the GVAD1010
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / GVAD1010 |
| Description | Product datasheet TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NO (fault) |
| Range | TeSys; TeSys Deca |
| Device short name | GVAD |
| Product or component type | Auxiliary contact block |
| Product compatibility | GV2L; GV2P; GV2RT; GV3L; GV2LE; GV3P; GV2ME |
| Mounting location | Left side |
| Auxiliary contacts operation | Fault signal 1 NO |
| Pole contact composition | 2 NO |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-1; 300 V conforming to UL 508; 300 V conforming to CSA C22.2 No 14 |
| [Ue] rated operational voltage | 48 to 690 V AC; 24 to 240 V DC |
| [Ith] conventional free air thermal | 6A |
| Mechanical durability | 100000 cycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Protection type | GB2CB– circuit breaker; GG fuse 10 A |
| Rated operational power in VA | 300 VA at 48 V AC-15 – electrical durability: 100000 cycles; 414 VA at 690 V AC-15 – electrical durability: 100000 cycles |
| Rated operational power in W | 120 W at 240 V DC-13 – electrical durability: 100000 cycles; 140 W at 110 V DC-13 – electrical durability: 100000 cycles |
| Height | 89 mm |
| Width | 9.3 mm |
| Depth | 66 mm |
| Net weight | 0.055 kg |
| Environmental characteristic | Normal environment |
| Product certifications | UKCA |
Ordering checklist for the GVAD1010
- Both contacts normally open; the fault signal is one of them.
- Match the PLC input type to closing signals.
- Check compatibility of the breaker with the listed GV2 and GV3 types.
- Check that the signal voltage is within 24 to 240 V DC or 48 to 690 V AC.
- Keep the contact function written on the wiring schedule.
GVAD family: the GVAD1010 against its siblings
The four references below share the same left-side mounting and ratings and differ only in contact pattern and lifecycle status.
| Reference | Contacts | Fault signal contact | Status in datasheet |
|---|---|---|---|
| GVAD0101 | 2 NC | Fault signal 1 NC | Discontinued (17 Jul 2023) |
| GVAD0110 | 1 NO + 1 NC | Fault signal 1 NC | Listed |
| GVAD1001 | 1 NO + 1 NC | Fault signal 1 NO | Listed |
| GVAD1010 | 2 NO | Fault signal 1 NO | Listed |
What the GVAD1010 fits and how it is rated
The block mounts at the left of GV2ME, GV2P, GV2L, GV2LE, GV2RT, GV3L and GV3P breakers, as the datasheet states. With 9.3 mm width it keeps a row of breakers compact.
Electrical limits are the same as in the other family members: 6 A conventional thermal current, 2.5 A on the fault contact, 48 to 690 V AC, 24 to 240 V DC, and 5 mA and 17 V as minimum switching level.
The block mounts on the left side of the breaker and is 9.3 mm wide, 89 mm high and 66 mm deep, with a net weight of 0.055 kg. The datasheet lists a rated operational voltage of 48 to 690 V AC and 24 to 240 V DC, a conventional thermal current of 6 A, and 2.5 A for the fault-signalling contact. Rated operational power at AC-15 is 720 VA at 230 to 240 V and 850 VA at 380 to 415 V, each with an electrical durability of 100000 cycles; the DC-13 figures include 120 W at 240 V DC.
Commissioning notes for the GVAD1010
Fit with the feeder isolated, check continuity at each terminal pair in both breaker positions, and record which terminal is the fault contact and which is the status contact. The datasheet gives mechanical durability as 100000 cycles, so no extra maintenance is needed in ordinary use.
When replacing a block on a running plant, plan the shutdown of the feeder; the block cannot be changed live.
GVAD1010 in Oman and GCC installations
Packaged plant such as chiller skids, fire-water pump panels and compressor starters report their breaker status with closing contacts to the site DCS. Two NO contacts on one block save an extra accessory.
Where panels are built to a standard of closing signals, the GVAD1010 is the usual spare to hold in stock.
Reading the two contacts of the GVAD1010
With both contacts normally open, each one gives a closing signal. One reports the fault condition, the other reports the status of the breaker. Neither carries a supervised loop, so a broken cable shows up as a missing signal and not as an alarm.
If your design relies on loop supervision, specify a block with a normally closed fault contact. If it uses simple lamp or counter inputs, the GVAD1010 keeps the logic uniform: all signals are closing signals.
Information to send with an RFQ for the GVAD1010
- Full reference and quantity required
- Breaker model (GV2 or GV3 type) the block must fit
- Contact logic needed (NO or NC fault signal)
- Signal voltage and the input card that reads it
- Delivery location and timing
Storage, handling and spares for the GVAD1010
Keep the GVAD1010 in its original packaging in a dry, dust-free store until installation, and check the label against the order before fitting. For plants that run continuously, holding one spare unit on site shortens downtime if a replacement is needed during a shutdown or after a fault. Record the reference and installation date in the maintenance log so the next order can be placed quickly.
Documents and quotation
A datasheet for the GVAD1010 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.
Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Tesys Gvad Range
Seven Star LLC supplies models from the Se Tesys Gvad range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric GVAD0101 TeSys GV2/GV3 2 NC Contact Block | Contactors & Overload Relays | View details |
| Schneider Electric GVAD0110 TeSys GV2/GV3 1 NO + 1 NC Contact | Contactors & Overload Relays | View details |
| Schneider Electric GVAD1001 TeSys GV2/GV3 1 NC + 1 NO Contact | Contactors & Overload Relays | View details |
| Schneider Electric GVAD1010 TeSys GV2/GV3 2 NO Contact Block | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric GVAD1010 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric GVAD1010 TeSys GV2/GV3 2 NO
Answers from our engineering team on installation, compatibility and integration.
01What contacts does the GVAD1010 have?
Two normally open contacts, one of which is the fault signal.
02Does the GVAD1010 have a normally closed contact?
No. Its pole composition in the datasheet is 2 NO.
03Which breakers fit the GVAD1010?
GV2ME, GV2P, GV2L, GV2LE, GV2RT, GV3L and GV3P.
04Which AC-15 power is listed for the GVAD1010?
720 VA at 230 to 240 V and 850 VA at 380 to 415 V, with 100000 cycles of electrical durability.
05How heavy is the GVAD1010?
0.055 kg. See the datasheet linked on this page for the full figures.


















Reviews