Schneider Electric LC1F185M7 TeSys F 185 A Contactor 220 V AC

Description

LC1F185M7 large-frame 185 A contactor for heavy motors

The LC1F185M7 is a Schneider Electric product listed in the datasheet as: Contactor, TeSys F, 3P(3NO), AC-3 <=440V 185A, 220V AC coil. The LC1F185M7 is a large three-pole TeSys F contactor rated at 185 A in AC-3 up to 440 V. The F range covers the heavy end of motor starting, where the contactor is bolted to a plate and cables are connected with lugs. Seven Star LLC supplies the LC1F185M7 in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference: LC1F is the TeSys F range, 185 is the AC-3 current in amps at up to 440 V, and M7 is the coil code for 220 V AC. Check the datasheet lifecycle notice, because this reference is shown as discontinued, which makes it a replacement part for existing panels.

Technical specifications of the LC1F185M7

Parameter Specification
Manufacturer / part number Schneider Electric / LC1F185M7
Description Contactor, TeSys F, 3P(3NO), AC-3 <=440V 185A, 220V AC coil
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Motor control; Resistive load
Utilisation category AC-3; AC-4; AC-1
Poles description 3P
[Ue] rated operational voltage <= 460 V DC; <= 690 V AC 50/60 Hz
[Uc] control circuit voltage 220 V AC 40 to 400 Hz
[Ie] rated operational current 275 A (at <40 °C) at <= 440 V AC-1; 185 A (at <55 °C) at <= 440 V AC-3
[Uimp] rated impulse withstand 8 kV
[Ith] conventional free air thermal 275 A (at 40 °C)
Rated breaking capacity 1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand 1500 A 40 °C – 10 s
current 920 A 40 °C – 30 s; 740 A 40 °C – 1 min; 500 A 40 °C – 3 min; 400 A 40 °C – 10 min
Associated fuse rating 200 A aM at <= 440 V; 315 A gG at <= 440 V
Average impedance 0.33 mOhm – Ith 275 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1; 1500 V VDE 0110 group C
Power dissipation per pole 12 W AC-3; 25 W AC-1
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 90 kW at 380 to 400 V AC 50/60 Hz (AC-3); 100 kW at 415 V AC 50/60 Hz (AC-3); 100 kW at 440 V AC 50/60 Hz (AC-3)
Control circuit voltage limits Operational 0.85 to 1.1 Uc 40 to 400 Hz 55 °C; Drop-out 0.2 to 0.55 Uc 40 to 400 Hz 55 °C
Mechanical durability 10 Mcycles
Inrush power in VA 1070 VA, 40 to 400 Hz 0.9 20 °C
Hold-in power consumption in VA 9.9 VA, 40 to 400 Hz 0.9 20 °C
Maximum operating rate 2400 cyc/h 55 °C
Operating time 35 ms closing at Uc; 130 ms opening at Uc
Connections – terminals Control circuit screw clamp terminals 1 1 to 4 mm²flexible without cable end
Mounting Support Plate
Heat dissipation 8 to 9.8 W
motor power range 30 to 50 kW 200 to 240 V 3 phase; 55 to 100 kW 200 to 240 V 3 phase; 55 to 100 kW 380 to 440 V 3 phase; 55 to 100 kW 480 to 500 V 3 phase
Motor starter type Direct on-line contactor
Contactor coil voltage 220 V AC standard
Standards IEC 60947-4-1; JIS C8201-4-1; EN 60947-4-1; IEC 60947-1; EN 60947-1
Product Certifications LROS (Lloyds register of shipping); RMRoS; UL; BV; RINA; CSA; DNV; ABS; CB; UKCA
Compatibility code LC1F
Control circuit type AC 40 to 400 Hz
IP degree of protection IP2X front face with shrouds IEC 60529; IP2X front face with shrouds VDE 0106
Ambient air temperature (operation or storage, as listed) -60 to 80 °C

Power and coil data of the LC1F185M7

Rated motor power: 90 kW at 380 to 400 V AC 50/60 Hz (AC-3); 100 kW at 415 V AC 50/60 Hz (AC-3); 100 kW at 440 V AC 50/60 Hz (AC-3). Rated operational voltage: <= 460 V DC; <= 690 V AC 50/60 Hz. Rated operational current: 275 A (at <40 °C) at <= 440 V AC-1; 185 A (at <55 °C) at <= 440 V AC-3. Utilisation categories: AC-3; AC-4; AC-1. Motor power ratings: 90 kW at 380 to 400 V AC 50/60 Hz (AC-3); 100 kW at 415 V AC 50/60 Hz (AC-3); 100 kW at 440 V AC 50/60 Hz (AC-3). Coil or control voltage: 220 V AC 40 to 400 Hz. Mechanical durability: 10 Mcycles.

The coil of a large contactor draws a high inrush when it closes, so the control transformer and wiring must be sized for that peak, not for the hold-in value. The datasheet lists coil consumption values you should compare with the control circuit.

Replacement and successor planning for the LC1F185M7

Because the datasheet carries a discontinued notice, treat this part as a spare or replacement and confirm with the supplier the successor reference, coil code, terminal shrouds and accessories before ordering. Auxiliary contact blocks, mechanical interlocks and coil suppressors from the same family should be checked for fit.

When a panel contains several LC1F units, standardise the coil voltage and keep a complete spare with the same coil code.

The datasheet downloaded for this page carries lifecycle notices: Discontinued on: Jun 15, 2023. For a plant that already runs this reference that makes the LC1F185M7 a spare-and-replacement item, and it is worth fixing the stock level and the long-term successor plan at the same time. We can discuss compatible alternatives once we know the installation.

Selection checklist for the LC1F185M7

  • Motor current and duty class (AC-3 185 A at up to 440 V).
  • Coil voltage: 220 V AC for this reference; check the control supply.
  • Lifecycle status and a successor plan.
  • Thermal overload relay or electronic relay range for the motor.
  • Cable lugs and busbar connection method.
  • Accessories: auxiliary blocks, suppressors, interlock kit.

Handling, fitting and testing of the LC1F185M7

A contactor in this class is heavy; use two people or lifting aids when fitting it in a tall panel. Fix it with the specified screws on a rigid plate, use cable lugs of the correct size and apply the torque of the datasheet.

After fitting, check manual operation of the armature, measure coil resistance and perform a dry run before connecting the motor load.

Typical applications of the LC1F185M7 in Oman and the GCC

In Oman and the GCC large contactors of this class are found on crude and water transfer pumps, compressors, large fans and crushers, often in older MCC panels that are still in service and need like-for-like replacement.

Dimensions, environment and approvals of the LC1F185M7

For the LC1F185M7, plan the mounting space from the datasheet: 168.5 mm (W) x 174 mm (H) x 181 mm (D). The LC1F185M7 weighs 4.65 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.

Ambient temperature limits in the datasheet: -60 to 80 °C. Ingress protection: IP2X front face with shrouds IEC 60529; IP2X front face with shrouds VDE 0106. Operating altitude: 3000 m without derating. Standards listed: IEC 60947-4-1; JIS C8201-4-1; EN 60947-4-1; IEC 60947-1; EN 60947-1. Certifications listed for this reference: LROS (Lloyds register of shipping); RMRoS; UL; BV; RINA; CSA; DNV; ABS; CB; UKCA.

Information to send with an RFQ for the LC1F185M7

  • Full reference and quantity required
  • Existing equipment, panel or rack it must fit
  • Supply voltage, load or signal details of the application
  • Required delivery location and timing
  • Whether a spare, a replacement or a new installation

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.

Datasheets & Documents
  • PDF Datasheet Schneider Electric LC1F185M7 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LC1F185M7 TeSys F 185 A

Answers from our engineering team on installation, compatibility and integration.

01What is the net weight of the LC1F185M7?
The datasheet gives 4.65 kg.
02What ingress protection does the LC1F185M7 list?
Stated as IP2X front face with shrouds IEC 60529; IP2X front face with shrouds VDE 0106.
03Which standards does the LC1F185M7 list?
Listed: IEC 60947-4-1; JIS C8201-4-1; EN 60947-4-1; IEC 60947-1; EN 60947-1.
04Which product range does the LC1F185M7 belong to?
The datasheet lists the range as TeSys F.
05What is the device short name of the LC1F185M7?