Brand: Endress+Hauser (E & H)
Endress+Hauser TM131 iTHERM Thermometer, Welded Thermowell
Description
Endress+Hauser TM131 iTHERM ModuLine thermometer with welded thermowell
The Endress+Hauser TM131 is a metric RTD or thermocouple thermometer with a welded protection tube (thermowell) for general industrial process lines. In the iTHERM ModuLine range it is the all-round model: a thermowell made from tube material, a replaceable insert, an extension neck and a terminal head, all configured to the pipe or vessel. The datasheet states a measuring range of –200 to +1,100 °C and a pressure rating up to 100 bar.
Seven Star LLC supplies the TM131 in Oman and the GCC as an independent supplier in Muscat. The model name identifies the construction, not a single ordering code, so sensor, thermowell, connection and head are set per tag when we quote.
Within the same family, the TM151 (barstock thermowell, higher pressure) and the TM111 (direct contact, no thermowell) cover the other mechanical constructions, and the TM152 is the imperial barstock version.
TM131 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser / TM131 (iTHERM ModuLine, welded thermowell, metric) |
| Sensor | Pt100 RTD (thin-film or wire-wound) or thermocouple type K, J or N |
| Measuring range | –200 to +1,100 °C overall; Pt100 thin-film StrongSens –50 to +500 °C, QuickSens –50 to +200 °C, wire-wound –200 to +600 °C |
| Thermocouple range | Type K –40 to +1,100 °C; type J –40 to +750 °C; type N –40 to +1,100 °C |
| Accuracy | RTD class A and AA to IEC 60751; class B on the basic version; thermocouples class 1 or 2 to IEC 60584-2, class special or standard to ASTM E230 |
| Maximum process pressure | Up to 100 bar, depending on configuration; threaded connection limit 400 bar at +400 °C |
| Process temperature | Depends on sensor and thermowell material; fast-responding thermowell limited to +400 °C |
| Response time | From t90 below 10 s with thermowell, depending on configuration; QuickSens insert 1.5 s class |
| Vibration resistance | Up to 60g with StrongSens and 6 mm QuickSens inserts; 3g for standard elements |
| Ingress protection | Up to IP66, partly IP68 (1.83 m for 24 h), depending on head |
| Weight | 1 to 10 kg for standard versions |
| Thermowell materials | 316, 316L/1.4435, 316Ti, Alloy C276, Alloy 600 (per configuration) |
How the TM131 builds its measurement
The insert, an iTHERM TS111 (RTD) or TS211 (thermocouple), slides into the thermowell and is spring-loaded against the bottom so heat transfers well. Pt100 inserts measure resistance; thermocouples generate a small voltage proportional to the difference between the hot junction and the cold junction. Thin-film Pt100 elements are small and vibration tolerant. Wire-wound elements are the choice when the process runs hotter than +500 °C or needs the tightest long-term stability.
Thermowell tips follow DIN 43772: Form 2 is straight, Form 3 is tapered, and G or F marks a threaded or flanged connection. A tapered tip is stiffer, which helps at higher flow velocity; a reduced tip speeds the response. The datasheet provides flow-velocity charts for water and superheated steam at 50 bar so you can see how immersion length limits allowable velocity. Always run the thermowell load check for your pressure, temperature and velocity.
Dual Seal and other safety features on the TM131
Process safety is the strongest argument for choosing the TM131 over a basic thermometer. A special extension neck carries a second process seal, called Dual Seal. If the thermowell fails, the process medium stays enclosed and cannot enter the terminal head or the wiring. A pressure switch signals an increase in pressure inside the seal compartment, so maintenance gets a warning while measurement continues for a short period. The datasheet shows two ways to carry that signal: a two-channel iTEMP transmitter on HART, using the second channel for the sensor-break alarm, or a two-channel PROFINET transmitter.
The TM131 also supports tool-free removal through the iTHERM QuickNeck (neck rated –50 to +140 °C), Bluetooth connectivity on the head transmitter, and the explosion-protection approvals named on the datasheet cover: ATEX, IECEx, CSA and NEPSI. Check the approval against the exact configuration quoted.
Process connections and thermowell geometry for TM131
- Threaded male connections: M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2, G 1/2 and G 1 (BSP), supplied with copper seals to DIN 7603 form A
- Flanged and welded variants according to DIN 43772 forms 2G, 2F, 3G and 3F
- Continuous thermowell (lagging kept above the connection), hexagonal-extension thermowell, or a thermowell without lagging for compression fittings
- Version for installation in a separate customer thermowell, which cannot be used for direct immersion
The immersion length U, lagging T and neck length E set the insertion length of the insert. Because the neck length changes by design (fixed, hexagonal or QuickNeck), quote the full geometry so the correct replaceable insert can be delivered.
TM131 compared with sibling iTHERM models
| Model | Thermowell | Pressure | Best fit |
|---|---|---|---|
| TM111 | None, insert touches the medium | Up to 75 bar | Low-cost, fast, clean fluids |
| TM121 | Welded tube, basic | Up to 50 bar | Non-hazardous, economic |
| TM131 | Welded tube, full option set | Up to 100 bar | General industry, Dual Seal, hazardous areas |
| TM151 | Barstock (drilled) | Up to 500 bar | High pressure, heavy duty |
The TM131 is the logical middle point: more option depth than the TM121 and more affordable than the barstock TM151 when pressure stays within 100 bar.
Selection and ordering checklist for the TM131
- Pipe or vessel connection standard and size; flange rating if flanged
- Maximum process temperature and pressure; flow velocity in the pipe
- Thermowell material, diameter and tip shape; immersion length
- Sensor: Pt100 class A or AA, thermocouple K, J or N; single or dual
- Neck type: fixed, hexagonal or QuickNeck; Dual Seal required or not
- Head type and material; M20 or NPT cable entries; display
- Transmitter and protocol (4–20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus, IO-Link, PROFINET)
- Hazardous-area zone and approval
- Calibration certificate and material test certificates
Installation, commissioning and maintenance of the TM131
Fit the thermowell first and pressure-test the line, then insert the thermometer; this is exactly why the replaceable-insert design pays off. Check the spring travel so that the tip sits on the bottom of the thermowell. Use a new copper seal on cylindrical threads. In terminal heads with a transmitter, the ambient limit is –40 to +85 °C (–30 with display).
Planned maintenance is simple: remove the insert via the QuickNeck or the head, calibrate or swap it, and replace it without opening the process. For spares quote the serial number so the insertion length is calculated for you.
TM131 applications in Oman and the GCC
The TM131 suits the standard temperature points of oil and gas gathering and processing, refinery and petrochemical units, power generation, desalination plants, and utility headers. Typical tags include pump bearing oil lines, exchanger inlets and outlets, steam and condensate lines, and flue and exhaust gas ducts when a thermocouple is chosen. In desert sites, plan for solar heating of the head: a longer neck, a transmitter inside the head, and a suitable cable entry keep electronics within rating, and the IP66 housing resists fine dust and humid coastal air.
Information to send with a TM131 request for quotation
- Tag, service, P&ID reference and quantity
- Process medium, temperature, pressure and flow velocity
- Connection type, size, flange rating or thread
- Thermowell material, tip form, immersion length
- Sensor, accuracy class, Dual Seal requirement
- Head, transmitter, output protocol, hazardous-area details
- Certificates and delivery site in Oman or the GCC
Documents and quotation
The manufacturer technical information for the TM131 is attached to this page. Read it together with your project specification, because the thermowell, sensor, head and transmitter options that apply to your tag are fixed by the order configuration, not by the model name alone. Approvals and ratings should always be checked against the exact configuration that is quoted.
Seven Star LLC quotes against your data sheet or loop drawing and confirms lead time, stock position and the documents that ship with the instrument. Send us the details listed above and we will respond with a priced offer for delivery in Oman and the wider GCC.
Other Models in the Eh Itherm Moduline Range
Seven Star LLC supplies models from the Eh Itherm Moduline range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser TM411 iTHERM Hygienic RTD Thermometer | Temperature Instrumentation | View details |
| Endress+Hauser TM131 iTHERM Thermometer, Welded Thermowell | Temperature Instrumentation | You are viewing this model |
| Endress+Hauser TM151 iTHERM Barstock Thermowell Thermometer | Temperature Instrumentation | View details |
Datasheets & Documents
- Datasheet Endress+Hauser TM131 Technical Information Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser TM131 iTHERM Thermometer, Welded
Answers from our engineering team on installation, compatibility and integration.
01What is the Endress+Hauser TM131?
It is a metric iTHERM ModuLine thermometer with a welded protection tube. It takes a replaceable Pt100 or thermocouple insert and is aimed at general industrial process temperature points.
02What pressure and temperature does the TM131 support?
The datasheet gives a measuring range of –200 to +1,100 °C and a pressure rating up to 100 bar. The real limit depends on the sensor, thermowell material and process connection.
03What is Dual Seal on the TM131?
Dual Seal is an optional extension neck with a second process seal. If the thermowell fails, the medium is held back from the head and wiring, and a pressure switch raises an alarm.
04How is the TM131 different from the TM151?
The TM131 uses a welded tube thermowell for up to 100 bar, while the TM151 uses a drilled barstock thermowell for pressure up to 500 bar and heavier duty.
05Which sensors can be fitted in the TM131?
Pt100 thin-film (standard, StrongSens, QuickSens) or wire-wound inserts, and thermocouples type K, J or N, in grounded or ungrounded form according to the datasheet.