Endress+Hauser TM401 iTHERM ModuLine Hygienic RTD Thermometer
Description
TM401 iTHERM ModuLine metric hygienic RTD thermometer
The Endress+Hauser TM401 is a direct-contact Pt100 resistance thermometer for hygienic and aseptic processes. It belongs to the iTHERM ModuLine group, in which the "40x" models use basic technology: a fixed, non-replaceable insert, a standard extension neck and use in non-hazardous areas only. The TM401 is the metric version, with millimetre probe diameters and metric process connections. Seven Star LLC supplies the TM401 in Oman and the GCC as an independent supplier in Muscat.
Because the sensor is in direct contact with the product, there is no thermowell and the response is quick. The wetted parts are 316L stainless steel, the probe is available in 6 mm or 8 mm diameter with a straight or reduced tip, and a long list of sanitary connections allows the thermometer to be matched to existing tank and pipe fittings. The manufacturer positions it as the value option for food, beverage and life-science plants.
TM401 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser iTHERM ModuLine TM401 |
| Measuring principle | Pt100 thin-film resistance thermometer (RTD), IEC 60751, α = 0.003851 |
| Measuring range | –50 to +200 °C |
| Accuracy | Class A per IEC 60751 from –30 to +200 °C; class B across the full range (basic thin-film sensor) |
| Insert | Fixed, without exchangeable insert; no thermowell |
| Probe diameter | 6.0 mm or 8.0 mm; straight or reduced tip |
| Immersion length | Up to 400 mm on request |
| Wetted material | 316L (1.4404) stainless steel; wetted surface Ra ≤ 0.76 µm standard, 0.38 µm optional |
| Process pressure (static) | 40 bar at 20 °C on the product page; the technical information quotes up to 50 bar depending on connection |
| Response time (water, 0.4 m/s) | Ø6 mm straight t50 5 s / t90 15.5 s; Ø6 mm reduced 3.5 s / 9 s; Ø8 mm reduced 5 s / 10.5 s |
| Thermal shock | CIP/SIP steam sterilisation: +5 to +130 °C within 2 s |
| Degree of protection | Up to IP69K depending on the terminal head and connector |
| Ambient temperature at the head | –40 to +85 °C with iTEMP head transmitter; –30 to +85 °C with display |
| Insulation resistance | ≥ 100 MΩ at ambient temperature, measured at 100 V DC |
| Weight | 0.5 to 2.5 kg for standard versions |
Data come from the manufacturer technical information and product page. The head transmitter, terminal head and cable gland chosen set the electrical limits of the complete assembly.
How the TM401 measures
The TM401 uses a thin-film platinum element: a micron-thin platinum layer on a ceramic substrate, which gives a small, vibration-tolerant sensor with a resistance of 100 Ω at 0 °C. The manufacturer notes that thin-film sensors deviate slightly from the standard curve at higher temperatures, which is why the tight class A tolerance applies only up to roughly 300 °C and, for this basic sensor, up to 200 °C. For the TM401 the practical limit is the 200 °C process range.
A head transmitter can be fitted in the terminal head to convert the sensor resistance into 4–20 mA, HART, PROFINET over Ethernet-APL or IO-Link output, and the transmitter family also includes PROFIBUS PA and FOUNDATION Fieldbus options. Using an iTEMP transmitter reduces wiring and also allows sensor-transmitter matching with Callendar-Van Dusen coefficients, which improves accuracy compared with a bare sensor. Self-heating is negligible when such a transmitter, with its very small measuring current, is connected.
TM401 hygienic design and process connections
A hygienic thermometer is judged by how it cleans as much as by how it measures. The TM401 is offered in versions without gaps and dead space, and the published certifications include 3-A (authorisation no. 1144, Sanitary Standard 74-07), EHEDG type EL Class I for the listed connections, ASME BPE with a certificate of conformity available for designated options, FDA compliance, and a TSE certificate of suitability confirming that no animal-derived materials are used on wetted parts. Materials in contact with product also meet the EU food-contact regulations named in the technical information. The certificates apply to listed connections and options, so confirm them against the configured order code.
Releasable and fixed process connections include:
- Tri-clamp and micro-clamp, and clamp connections to ISO 2852
- Sanitary connection to DIN 11851 (dairy fitting), SMS 1147 and Varivent (including types for VARINLINE housings)
- Ingold connection with a weld-in adapter, and Liquiphant-style G¾″ and G1″ adapters
- Spherical TK40 compression fitting, movable or fixed, for weld-in installation
- Versions without process connection, with M24x1.5 or ½″ NPT thread to the head
The counterpieces, seals and sealing rings are normally not supplied with the thermometer, so these must be ordered separately. Some connections have lower pressure limits, for example 16 bar for many clamp types and 10 bar for certain others.
Terminal heads and electrical options for TM401
All terminal heads follow DIN EN 50446 flat-face geometry with M24x1.5 or ½″ NPT thread to the thermometer. The TA30A is an aluminium head with polyester coating rated IP66/68 (IP66/67 for ATEX) with temperature rating –50 to +150 °C without cable gland. The TA30R is a 316L stainless head with standard IP69K, rated –50 to +130 °C without cable gland, designed for washdown. The TA30S is polypropylene, FDA-compliant, IP65, rated –40 to +85 °C, and white for dairy and clean areas. Cable glands and fieldbus connectors have their own temperature limits, which must be respected, as the manufacturer highlights.
Material resistance of the housing to the cleaning agents P3-topax 66, P3-topactive 200, 500 and OKTO, and to demineralised water, is stated in the technical information, which is helpful when the thermometer is washed down alongside the vessel.
TM401 versus TM402, TM411 and TM412
| Model | Version | Insert | Hazardous areas |
|---|---|---|---|
| TM401 | Metric (mm) | Fixed, non-replaceable | Non-hazardous areas |
| TM402 | Imperial (inch) | Fixed, non-replaceable | Non-hazardous areas |
| TM411 | Metric (mm) | Replaceable insert, QuickNeck | Hazardous-area approvals available |
| TM412 | Imperial (inch) | Replaceable insert, QuickNeck | Hazardous-area approvals available |
The TM401 is for plants working to metric piping and fittings. Where inch-based tri-clamp tube dimensions are used, the TM402 is the closer match. The higher-end TM411 and TM412 add a quick-fastening extension neck, vibration-resistant sensors and approvals for hazardous areas, and are chosen when the insert must be replaceable or the area is classified.
TM401 selection and ordering checklist
- Choose the probe diameter (6 mm or 8 mm), tip shape and immersion length, up to 400 mm on request.
- Name the process connection and size exactly, plus its seal, for example clamp size or Varivent type.
- State the surface finish required: standard Ra 0.76 µm, or 0.38 µm, and whether ASME BPE conformity is needed, since the buffed finish is not ASME BPE compliant.
- State which hygiene documents are needed: 3-A, EHEDG, ASME BPE, FDA or TSE.
- Specify the terminal head (aluminium, 316L or polypropylene) and the cable entry thread.
- Choose a head transmitter and its output, or order for direct wiring.
- Check the process pressure and CIP/SIP temperature against the connection limit.
- Request calibration, which covers the insert only, and a certificate if required.
Installing, cleaning and calibrating the TM401
Installation orientation has no restriction as long as the process self-drains, and any leak-detection opening must be at the lowest possible point. The immersion length influences accuracy: the tip must be in the stream and clear of the vessel wall, and in a pipe an angled or elbow installation can give a longer immersion. For EHEDG and 3-A cleanability, the thermometer length in the stub must not exceed the stated ratio to its diameter, so check the installation drawing before welding the adapter.
The manufacturer’s standard calibration is at reference temperatures between –80 and +600 °C on ITS-90, traceable to national standards, and only the insert is calibrated. If a head transmitter is used the minimum immersion length for a valid calibration is 50 mm above 80 °C. Keep a calibration record by serial number, and re-check periodically, especially after CIP/SIP cycles.
TM401 applications in Oman and the GCC
The TM401 belongs wherever product is heated, cooled or sterilised under hygiene rules. In the region this means dairy and juice plants, bottling and beverage lines, bakery and food processing, pharmaceutical and nutraceutical production, and cleanroom utilities such as water-for-injection and clean steam loops. It also suits brewing, cold-room and desalinated-water bottling facilities.
The heat and humidity of the Gulf point to a washdown-rated head, such as the 316L TA30R, in wet process halls, and to a head transmitter if cable runs to the PLC are long. The TM401 is for non-hazardous areas, so for solvent or powder zones a TM411 or other approved model should be considered.
What to send with your TM401 RFQ
- Full order code or nameplate photo of the thermometer being replaced.
- Probe diameter, immersion length, tip shape and surface finish.
- Process connection type, size and seal.
- Required hygiene certificates and material certificates.
- Terminal head, cable entry and head transmitter output.
- Quantity, delivery site and calibration needs.
Documents and quotation
A datasheet (Technical Information) for the TM401 is attached on this page, with the process connection drawings, sensor tolerances, response times and certificate list.
To receive a quotation, send the order code or the requirement from the list above and Seven Star LLC will confirm availability and lead time for Oman and the GCC.
Other Models in the Itherm Tm Range
Seven Star LLC supplies models from the Itherm Tm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser TM401 iTHERM ModuLine Hygienic RTD Thermometer | Temperature Instrumentation | You are viewing this model |
| Endress+Hauser TM402 iTHERM ModuLine Imperial Hygienic RTD | Temperature Instrumentation | View details |
Datasheets & Documents
- Datasheet Endress+Hauser TM401 Technical Information Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser TM401 iTHERM ModuLine Hygienic RTD
Answers from our engineering team on installation, compatibility and integration.
01What is the temperature range of the TM401?
The measuring range is –50 to +200 °C using a Pt100 thin-film sensor. It tolerates CIP/SIP temperature jumps from +5 to +130 °C within 2 seconds.
02Can the TM401 insert be replaced?
No. The TM401 has a fixed, non-replaceable insert and is meant for non-hazardous areas. The TM411 offers a replaceable insert with hazardous-area approvals.
03What is the difference between the TM401 and TM402?
The TM401 is the metric version (6 mm and 8 mm probes), while the TM402 is the imperial version (1/4 inch and 3/8 inch probes). Both use basic technology with a fixed insert.
04Which hygiene certificates apply to the TM401?
The technical information lists 3-A authorisation no. 1144, EHEDG type EL Class I for tested connections, ASME BPE for designated options, FDA compliance and TSE suitability. They apply to listed options, so confirm against the order code.
05Does the TM401 need a thermowell?
No. It is designed for direct contact with the product and is not intended for use with a thermowell, which keeps the response time short.