Lovato ATL100 Automatic Transfer Switch Controller

Description

Controller for automatic changeover between two supplies

A changeover panel for 2 sources needs a decision-making unit, and the ATL100 from Lovato Electric is one: Automatic transfer switch controller for 2 power sources, single phase control, modular housing. It checks both supplies continuously and switches the load to the healthy one.

Measuring inputs accept 110-230VAC with true RMS measurement, the supply range is 110-230 VAC, and the display is no.

Technical specifications

Parameter Specification
Order code ATL100
Product designation Automatic transfer switch controller for 2 power sources, single phase control, modular housing
Product type designation ATL100
Number of controlled power sources 2
Display No
Expandability No
Rated supply voltage AC 110-230 VAC
Operating supply voltage range AC 80-300 VAC
Rated frequency 50/60 Hz
Operating frequency range 45-66 Hz
Power consumption AC (Max) 7 VA
Maximum rated voltage Ue 110-230VAC
Measurement range 80-300 V
Frequency range 45-65 Hz
Measurement method True root mean square (TRMS)
phase-neutral above 8MΩ
Measuring accurancy ±0.25% f.s
Wiring mode Single-phase
Number of digital input 1 for rated voltage selection 110/230VAC
Number of relay output 3
Contact arrangement 2 x 2NO (OUT1, OUT2) + 1 x 1NO (alarm)
Electrical life OUT1, OUT2: 10⁵ Alarm output: 10⁵ cycles
Mechanical life OUT1, OUT2: 1 x 10⁷ Alarm output: 2 x 10⁷ cycles
Operating temperature (min) -30 °C
Operating temperature (max) +70 °C
Storage temperature (min) -30 °C
Storage temperature (max) +80 °C
Maximum Pollution degree 2
Overvoltage category 3
Climatic sequence Z/ABDM (IEC/EN 60068-2-61)
Shock resistance 15g (IEC/EN 60068-2-27)
Vibration resistance 0.7g (IEC/EN 60068-2-6)
Execution Modular housing (3 modules DIN 43880)
Material Polyamide
Mounting 35mm DIN rail (IEC/EN 60715) or screw-type by means of removable clips
Degree of protection IP40 on front, IP20 on terminals
Dimensions (W x H x D) 53.5 x 104.7 x 63 mm
Weight 300 g

Selecting the version

Model choice follows the topology (single-phase or three-phase, two or three sources, with or without tie-breaker) and then the extras: expansion slots, optical port, NFC set-up.

Confirm that the output relays can drive your contactor coils directly or add interposing relays where the datasheet ratings are exceeded.

Applications and installation

Where a site has utility power and a standby generator, the controller handles the changeover logic: it can issue the generator start command, wait for stable voltage and then transfer the load.

Dimensions are listed in the table. Relay outputs and inputs are programmable; use the Xpress software or the optical interface to configure.

For panel design and commissioning, the practical figures to keep at hand are: measuring accurancy ±0.25% f.s; wiring mode Single-phase; climatic sequence Z/ABDM (IEC/EN 60068-2-61); shock resistance 15g (IEC/EN 60068-2-27); vibration resistance 0.7g (IEC/EN 60068-2-6); execution Modular housing (3 modules DIN 43880); material Polyamide; mounting 35mm DIN rail (IEC/EN 60715) or screw-type by means of removable clips; degree of protection IP40 on front, IP20 on terminals; dimensions (W x H x D) 53.5 x 104.7 x 63 mm; weight 300 g; operating temperature (min) -30 °C; operating temperature (max) +70 °C; number of relay output 3. These come straight from the datasheet and are repeated here so that the key installation limits are visible without opening the PDF.

Related Lovato Electric products: Lovato ATL600 Automatic Transfer Switch Controller 2 Sources, Lovato DCRL8 8-Step Automatic Power Factor Controller, Lovato LVM20A240 LVM20 Level Control Relay, Lovato LVM40A240 LVM40 Level Control Relay, Lovato PMIB1A230 Insulation Monitoring Relay for IT Networks and Lovato LVMP30A240 LVMP30 Pump Start-Up Priority Change Relay.

Documents and quotation

Download the attached datasheet for ATL100 from the Lovato Electric online catalogue (English) to see every parameter in full. Check the number of sources, the supply voltages, the contactor or breaker type and the generator start arrangement against your own drawings first; the manufacturer may update datasheet figures without notice. More products of this type are under controllers & data acquisition. Use the quotation form with the code ATL100 and your quantity; availability is confirmed by Seven Star LLC, an independent supplier in Muscat.

Datasheets & Documents
  • PDF Datasheet Lovato Electric ATL100 datasheet (EN, catalogue export) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.

Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.

Lovato Electric at a glance

Established 1922, Bergamo, Italy
Headquarters Gorle (Bergamo), Italy
Ownership Private, family-run for four generations
Product families Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs

Lovato products we list

Family Models Typical use
Contactors BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing Switching motors, heaters, lighting and capacitor banks
Motor protection and starters SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay Short-circuit and overload protection and direct starting of motors
Soft starters ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 Reducing starting current and mechanical shock on pumps, fans and compressors
Variable speed drives VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 Speed control of pumps, fans and conveyors to save energy
Power management and control DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC Power factor correction, mains/generator changeover and energy monitoring

Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.

Where Lovato products are used

In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.

Ordering Lovato products: what we need

Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.

Facts checked against Lovato Electric company profile brochures, October 2026.

FAQ

Questions about the Lovato ATL100 Automatic Transfer Switch Controller

Answers from our engineering team on installation, compatibility and integration.

01How many power sources does the ATL100 control?
2.
02What display does it have?
No.
03What supply range does it accept?
110-230 VAC.
04How many relay outputs does it have?
3.
05What is the weight of the ATL100?
300 g.