Brand: Hydac
Hydac HNT 1226-B-0280-000 Level Transmitter, 0 to 10 V
Description
A float level transmitter with a 0 to 10 V output
The Hydac HNT 1226-B-0280-000 (HYDAC part number 924387) is a float-based level transmitter from the HNT 1100 family. A magnetostrictive sensor follows the float position and outputs a continuous 0 to 10 V signal proportional to the fluid level, so a PLC analogue input can display the tank content directly. The pressure-resistant stainless steel housing screws into the tank wall through a G3/4 A thread.
The probe in this code is 280 mm (11.02 inches) long with a measuring range of 0 to 208 mm, and the output is available as 0 to 10 V on three conductors through a four-pole M12x1 connector.
Technical specifications
| Parameter | Specification |
|---|---|
| HYDAC part number | 924387 |
| Model code | HNT 1226-B-0280-000 |
| Sensor type | Magnetostrictive, float-based |
| Probe length | 280 mm (11.02 in) |
| Measuring range | 0 to 208 mm |
| Output signal | 0 to 10 V, 3-conductor (load 1 kohm min.) |
| Accuracy | 1 % FS; non-linearity 1 % FS; repeatability 1 % FS; hysteresis 1 % FS |
| Mechanical connection | G3/4 A DIN 3852, male; 30 N·m |
| Wetted parts | Rod stainless steel 1.4301 / 1.4571; float PP; seal ring DIN 3869-27 FKM |
| Fluids | Hydraulic oils, cooling lubricants; others on request |
| Max. tank pressure | 43.5 psi; short-term 145 psi |
| Supply voltage | 9 to 36 V DC |
| Current consumption | 100 mA max. |
| Electrical connection | Male M12x1, 4-pole |
| Operating temperature | -25 to +85 °C |
| Fluid temperature | -25 to +120 °C |
| Storage temperature | -40 to +100 °C |
| Temperature coefficient | 0.01 % FS/°C max. |
| Protection class | IP 67 |
| Vibration / shock | 7.5 mm (5 to 8.2 Hz) and 2.0 g (8.2 to 150 Hz) / 20 g |
| Weight | 2.2 lb |
| Approvals as printed | CE (EN 61000-6-1/2/3/4) |
Code decoding
HNT 1 2 2 X – X – XXXX – 000 in the datasheet: 2 means no temperature sensor, 2 the G3/4 A thread, then the electrical connection (1 flying lead 2 m, 6 four-pole M12x1, 8 five-pole M12x1), then the output (B is 0 to 10 V, C is 4 to 20 mA on three conductors), and the probe length in mm. For HNT 1226-B-0280-000 that gives a 280 mm probe, 0 to 10 V and the four-pole plug. Pin 1 is +UB, pin 3 is 0 V and pin 4 the signal.
Choosing output and probe
If the controller expects a current loop, order the C version; for long cable runs a 4 to 20 mA output generally resists interference better than a voltage signal. The datasheet lists probe lengths of 250, 280, 370, 410, 520 and 730 mm as standard, with up to 2500 mm on request. A switch version of this family, the HNS 3000, is also in our catalogue and adds a display and relays. The USA datasheet for this transmitter is E 18.604.1.0.
Fit the float over the rod in the correct orientation before closing the tank, keep the probe away from suction flows that could tilt the float, and check the clearance below the lowest level required. Allow for the dead zones at the top and bottom of the rod, where the sensor cannot follow the float, when you convert the signal to tank volume in the PLC, and scale the 0 to 10 V span to the 208 mm measuring range.
Documents and quotation
The datasheet is attached. Send the tank depth, the fluid and the required output. See also our level instrumentation range.
How the HNT 1226-B-0280-000 works
The HNT 1226-B-0280-000 works on the magnetostrictive principle. A waveguide inside the stainless steel probe tube carries a short current pulse from the sensor head. The float, which carries a ring magnet, rides on the tube at the liquid surface. Where the pulse’s magnetic field meets the field of the float magnet, a mechanical torsion wave is created in the waveguide and travels back to the head. The time between the start pulse and the returning wave is measured and converted into the float position. The electronics then scale this position over the measuring range and output it as a 0 to 10 V signal on the 3-conductor connection.
Because the position is measured without contact, there is no wiper or reed chain to wear, and the signal changes continuously rather than in steps. HYDAC specifies a rise time of 30 ms and accuracy, non-linearity, repeatability and hysteresis of ±1 % FS each to DIN 16086, for calm, non-turbulent fluid.
Signal scaling and wiring
| Item | Value for this model |
|---|---|
| Probe length (physical) | 280 mm / 11.02 in |
| Measuring range | 8.19 in (208 mm) |
| Output | 0 to 10 V, minimum load 1 kΩ |
| Signal resolution in the PLC | approx. 1.2 V per inch of level (10 V / 8.19 in) |
| Pin 1 | +UB (9 to 36 V DC) |
| Pin 2 | n.c. |
| Pin 3 | 0 V |
| Pin 4 | Signal |
The output signals can be connected to HYDAC measurement and control devices and to standard evaluation systems such as PLC analogue inputs. Reverse-polarity protection of the supply, excess-voltage, override and short-circuit protection are provided.
HNT 1226-B-0280-000 selection & ordering guide
- Electrical connection: 1 = flying lead 2 m (core colours brown +UB, white 0 V, green signal); 6 = M12×1 4-pole (this model); 8 = M12×1 5-pole.
- Output: B = 0 to 10 V (this model); C = 4 to 20 mA, load max. 500 Ω.
- Probe length: 0250, 0280, 0370, 0410, 0520 or 0730 mm, with matching measuring ranges of 7.01, 8.19, 11.73, 13.31, 17.64 and 25.90 in. Other lengths are available on request.
- Floats: several float variants exist, including stainless steel for aggressive media and polypropylene (0.6 kg/dm³). Check the float density against your fluid.
Our team can help confirm the correct ordering code when you replace an existing transmitter or need a different probe length.
Installation & maintenance
- The pressure-resistant stainless steel housing screws into a G3/4 A port. Maximum tank pressure is 43.5 psi, or 145 psi for less than one minute.
- Use a shielded cable for the analogue signal and keep it apart from motor and solenoid power wiring; for long runs the 4 to 20 mA version is the better choice.
- Check that the float slides freely and that sludge has not built up on the tube during scheduled tank service.
- Verify the signal at the lowest and highest levels after installation and set the PLC scaling to match.
Typical applications in Oman & the GCC
Continuous level signals are used for tank content display, refill control and early warning of leaks in hydraulic power units, lubrication systems and cooling-lubricant tanks on machine tools. In Oman and the GCC the HNT 1000 suits industrial hydraulics in steel, aluminium and cement plants, port cranes, and power units on oil and gas skids where a PLC tracks the tank level and trends oil loss over time.
Why source from Seven Star LLC
Seven Star LLC supplies HYDAC level transmitters and matching M12 connectors across Oman and the GCC. Request a quote for the HNT 1226-B-0280-000 and include the tank depth, fluid and required output.
Datasheets & Documents
- Datasheet Hydac HNT 1000 level transmitter datasheet (E 18.604.1.0, USA edition) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
Related products
Frequently Asked Questions
A 0 to 10 V analogue signal on three conductors.
280 mm (11.02 inches), with a 0 to 208 mm measuring range.
Accuracy, non-linearity, repeatability and hysteresis are each 1 % of full scale at most.
A G3/4 A male thread to DIN 3852 in stainless steel.
Yes. The letter C in the output position gives 4 to 20 mA on three conductors.