- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Isolator & Barrier
- Automation Software
- Machine Vision
- Robotics
Brand: Hydac
Hydac HFS 2145-1S-0001-0004-7-B-1-000 Flow Switch, 1 to 4 L/min
Description
A reed-contact flow switch for oil and lubrication circuits
The Hydac HFS 2145-1S-0001-0004-7-B-1-000 (HYDAC part number 922052) is a variable-area float flow switch from the HFS 2100 series for oils and viscous fluids. The flowing oil pushes a spring-loaded float, and when the magnet in the float reaches the preset position, a reed contact outside the fluid path switches. Because the contact is separated from the oil, the switch is robust and keeps working when the viscosity changes between 30 and 600 cSt.
This version has a switching range of 1 to 4 L/min on a 3/4 inch connection in a nickel-plated brass body, with a mechanical indicator and a single normally open contact.
Technical specifications
| Parameter | Specification |
|---|---|
| HYDAC part number | 922052 |
| Model code | HFS 2145-1S-0001-0004-7-B-1-000 |
| Measuring principle | Variable area float with external reed contact |
| Medium | Oils and viscous fluids, 30 to 600 cSt, free of solid particles |
| Switching range | 1 to 4 L/min (size 2) |
| Mechanical connection | 3/4 in (connection code 4 in the HYDAC model key; DN 20, wrench size 34 mm) |
| Housing material | Brass, nickel-plated |
| Switching output | 1 normally open reed contact (1S) |
| Switching capacity | Max. 250 V / 3 A / 100 VA (size 2, N/O contact, EN175301-803 plug) |
| Electrical connection | Male EN175301-803 (DIN 43650), connector supplied |
| Accuracy | ≤ ±10 % of full scale |
| Repeatability | 2 % of full scale max. |
| Max. operating pressure | 3625 psi (250 bar for size 2 brass in the datasheet) |
| Fluid temperature | -20 to +120 °C (-4 to 248 °F) |
| Pressure drop | 0.02 to 0.4 bar |
| Protection class | IP 65 with the connector fitted correctly |
| Mechanical indicator | Fitted (code 1) |
| Approvals as printed | CE mark |
| Weight | Approx. 1430 g (3.2 lb) with indicator, per the datasheet |
Order code in plain words
HFS 2 1 4 5 – 1S – 0001-0004 – 7 – B – 1 – 000: 2 is the variable-area float principle, 1 the measurement of oils and viscous fluids, 4 the 3/4 inch connection digit in the generic key and 5 the male EN175301-803 plug, 1S one normally open contact, 0001-0004 the 1 to 4 L/min range, 7 the 10 % accuracy class, B the nickel-plated brass housing, 1 the mechanical indicator and 000 the standard modification. For the 1 to 4 L/min range the datasheet offers 1/4, 1/2, 3/4 and 1 inch connections; the 3/4 inch version has an installation length of 152 mm, so confirm the port size against your pipework before ordering.
Where flow switches are used
The datasheet names central lubrication, oil circuit lubrication, transformers, cooling circuits, hydraulic systems, pumps, welding machines and laser systems, the chemical industry and research as applications. The contact opens when flow falls below the preset point, so the switch can guard a lubrication line against a blocked pump or a closed valve. Keep the oil free from solid particles, fit a strainer upstream, and stay away from strong external magnetic fields, such as electric motors, which can influence the reed contact.
Fit the switch where the flow is steady and the pipe is full, and choose the switching point so that it sits comfortably inside the 1 to 4 L/min range rather than at its edge. Where a second contact is needed for an alarm, ask for the 2S or 2W version, which fits the extra contact on the side at 90 degrees to the first.
Documents and quotation
The HFS 2100 datasheet is attached. Please state the oil, the switching point and the voltage. See also our flow indicators and switches range.
How the HFS 2145-1S-0001-0004-7-B-1-000 works
The HFS 2100 series uses the variable-area float principle. Inside the housing a spring-loaded float carries a permanent magnet. As oil flows through the switch, it pushes the float in the direction of flow against the spring, and the float position depends on the flow rate. A reed contact sits on the outside of the housing, separate from the fluid. When the magnet reaches the preset position, the reed contact switches. The switch casing can be moved steplessly along the housing, so the user can set the switching point anywhere inside the 1 to 4 L/min range.
On the HFS 2145-1S-0001-0004-7-B-1-000 the single normally open contact opens when the flow falls below the set point. This fail-safe behaviour means a broken wire or a lost flow both give the same alarm state in the controller. HYDAC states that the switch compensates for viscosity between 30 and 600 cSt and can be mounted in any position.
Datasheet values for HFS 2100 size 2
| Parameter | Value |
|---|---|
| Operating pressure | 250 bar (brass), 300 bar (stainless steel) |
| Pressure drop | 0.02 – 0.4 bar |
| Accuracy | ±10 % FS (3 % possible when calibrated to a certain viscosity) |
| Repeatability | 2 % FS max. |
| Operating (ambient) temperature | –20 to +70 °C |
| Fluid temperature, EN175301-803 plug | –20 to +120 °C (optional –20 to +160 °C) |
| Parts in contact with medium (brass) | Stainless steel 1.4571, FPM, nickel-plated brass, brass, hard ferrite |
| Pin assignment (21X5-XS) | 1 centre, 2 N/O contact, 3 not connected, earth on housing |
| Minimum contact load | 3 VA (change-over contact) |
| Installation length (3/4 in) | 152 mm |
Selection & ordering guide
- Range: size 2 ranges for oil run from 0.5–1.5 L/min up to 35–110 L/min. Choose a range where your alarm point sits near the middle.
- Connection: the third digit sets the thread (1 = 1/4″, 2 = 3/8″, 3 = 1/2″, 4 = 3/4″, 5 = 1″); options depend on the range.
- Plug: 5 = EN175301-803 (DIN 43650) with connector supplied, 6 = M12x1 4-pole without connector.
- Contacts: 1S, 2S, 1W or 2W. With two contacts the second is fitted at 90° to the first.
- Housing: B = nickel-plated brass, S = stainless steel 1.4571.
- Indicator: 0 = without, 1 = with mechanical indicator.
An ATEX version is also listed for potentially explosive areas. Our team can help confirm the correct ordering code for the HFS 2145-1S-0001-0004-7-B-1-000 or a variant with a different range, plug or housing.
Installation & maintenance
- The oil must not contain solid particles; HYDAC recommends a contamination strainer upstream.
- Keep the switch away from external magnetic fields such as electric motors, which can affect the reed contact.
- Observe the flow direction marked on the housing and use thread sealing suited to the oil.
- Set the switching point with the system running at the real oil temperature, then lock the casing.
- Check the switch point during routine maintenance and clean the strainer, because dirt on the float can change the switching behaviour.
Typical applications in Oman & the GCC
HYDAC lists central lubrication, oil circulation lubrication, transformers, cooling circuits, hydraulic systems, pumps, welding and laser systems, chemical plants and R&D. In Oman and the GCC the HFS 2145-1S-0001-0004-7-B-1-000 fits low-flow lube lines on compressors, gearboxes and turbines, transformer oil circuits and test rigs, where a simple and reliable no-flow alarm is needed.
Why source the HFS 2145-1S-0001-0004-7-B-1-000 from Seven Star LLC
Seven Star LLC supplies HYDAC flow switches and sensors across Oman and the GCC. Send us the model code, oil type, flow range and supply voltage to request a quote, and our team can help confirm the correct ordering code.
Datasheets & Documents
- Datasheet Hydac HFS 2100 flow switch for oils datasheet (E 18.379.1/11.13) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
Related products
Frequently Asked Questions
1 to 4 L/min.
One normally open reed contact, switching up to 3 A on the EN175301-803 plug version.
Oils and viscous fluids from 30 to 600 cSt that are free of solid particles.
Nickel-plated brass.
Within ±10 % of full scale, with a repeatability of 2 % of full scale.

Reviews