LAR QuickTOCuv Online UV Persulphate TOC Analyzer

Description

Overview

The LAR QuickTOCuv is a real-time online water analyzer that determines total organic carbon with the recognised UV persulphate oxidation method and an NDIR carbon dioxide detector. It continuously measures TC and TRUE TOC, including both non-purgeable (NPOC) and purgeable/volatile (POC/VOC) organic carbon, and can report BOD and COD values after correlation. The analyzer is aimed at cleaner water matrices where fast, affordable and continuous monitoring matters most: pure water, boiler feed water, condensate return, drinking water, surface water and wastewater. The latest generation of the LAR QuickTOCuv uses a 7" Siemens touchscreen HMI and offers OPC UA and Ethernet communication for plant networks.

Seven Star LLC supplies the LAR QuickTOCuv together with its reactors, UV emitters, pumps and other consumables to power plants, desalination operators, refineries and water utilities in Oman and across the GCC, with engineering support in Muscat.

Measurement Principle

In the UV persulphate method, the sample is acidified and mixed with a sodium persulphate digestion reagent, then passed through a UV reactor. Short-wave ultraviolet light activates the persulphate and generates strongly oxidising radicals that convert dissolved organic carbon to CO2. A carrier gas transfers this CO2 through a gas drying stage to the non-dispersive infrared detector, which measures it continuously. The analyzer comprises the UV reactor, a vessel for the standard solution, sample transfer with a precision tubing pump, an acid filter, the carrier gas drying system and the infrared analysis system. TOC determination follows DIN EN 1484 and US-EPA 415.2, as well as ISO 8245 and US-EPA 415.1.

The reactor is the heart of the LAR QuickTOCuv. An outer tube shields the operator from hazardous UV radiation, while an inner quartz-glass tube keeps the UV lamp out of direct contact with the sample; LAR states that this design allows safe operation for more than two years. Because measurement is continuous rather than batch-wise, changes in organic load show up almost immediately. The analyzer also runs regular automatic checks of the NDIR detector, including zero-point correction and sensitivity tests, and auto-calibrates with a liquid standard, so drifts are detected early and results stay precise.

Engineering Design of the LAR QuickTOCuv

The LAR QuickTOCuv is housed in a wall- or rack-mounted cabinet of 1140 × 600 × 350 mm weighing 75 kg. The standard housing is 1.5 mm powder-coated steel in RAL 7035, tested to IP65, with optional AISI 304L or AISI 316L stainless steel for corrosive environments. Purged and pressurised housings are available for hazardous areas, with explosion protection for Class I, Division 2, Zone 2, Groups A, B, C and D, temperature class T4, plus IECEx and ATEX Zone 1 and Zone 2 housing options. Listed approvals include cETLus, NFPA 496, UL 61010-1 and UL 698A.

Wetted materials are chosen for clean-water duty: Peripren influent tubing, Duran glassware, PVC effluent lines and stainless steel metal parts. The sample enters at a maximum of 0.2 bar through 4.8, 8 or 12 mm ID tubing and leaves pressure-less; a flow sampler can provide a constant, pressure-free supply. Particles up to 100 µm are accepted. Electrically, the analyzer draws 70 W from 100–240 V AC, provides two 0/4–20 mA outputs, and is wired to a customer terminal box. Options include dual-stream measurement, an ambient air preparation unit, a CO2 remover, and humidity and pressure sensors.

Key Features

The LAR QuickTOCuv focuses on fast, low-cost continuous TOC monitoring:

  • The UV persulphate method is an established, standard-compliant technique for TOC in pure and lightly loaded water.
  • Continuous measurement detects product spills, leaks and condensate contamination as soon as they occur.
  • The measuring range of 0.1 to 1,000 ppm TC or TOC covers condensate in the ppb region as well as wastewater.
  • Auto-calibration and automatic zero-point and sensitivity checks keep the NDIR detector accurate without operator effort.
  • Reduced reagent consumption and low maintenance keep the cost of ownership down.
  • Analyzer availability of at least 98 % is specified by the manufacturer.
  • OPC UA and Ethernet interfaces simplify integration with modern DCS and SCADA systems.
  • Purged hazardous-area housings allow installation close to the process in classified zones.

Industrial Applications

LAR gives typical ranges for the LAR QuickTOCuv of 100–1,000 µg/l TOC in water-steam cycles and condensate, 1–50 mg/l in cooling water, and 1–10 mg/l in drinking and surface water. In Oman these duties appear at combined-cycle power and water plants, where organic ingress into boiler feed water and condensate return must be caught before it damages boilers and turbines, at refineries and petrochemical units around Sohar and Duqm that monitor condensate return for hydrocarbon leaks, and at desalination and potable water plants that track organic load after treatment. Pharmaceutical, food and beverage producers also use it for process water.

Seven Star LLC supports the LAR QuickTOCuv with engineering support for Muscat, Sohar and Salalah projects, including supply of the UV reactor glassware, UV emitter, gas drying tubes and peristaltic pump that are replaced during routine maintenance. For heavily loaded, salty or particle-rich streams, we recommend reviewing the high-temperature QuickTOCultra instead.

Technical Specifications

LAR QuickTOCuv data according to the NE61 sheet in the Process Insights datasheet:

Parameter Specification
Model LAR QuickTOCuv online TOC water analyzer
Measuring principle UV persulphate oxidation with NDIR CO2 detection
Compliance DIN EN 1484:1997-08, ISO 8245:1999-03, US-EPA 415.1, US-EPA 415.2
Parameters TOC (NPOC + POC/VOC), NPOC, TC, DOC; COD and BOD by correlation
Measuring range 0.1–1,000 ppm TC or TOC
Accuracy / repeatability Max. 3 % of FSR each
Cycle Continuous determination
Particle size ≤ 100 µm
Medium limits Max. 50 °C; inlet max. 0.2 bar; outlet pressure-less
Ambient temperature 5–35 °C (10–30 °C recommended)
Outputs / interface 2 × 0/4–20 mA; OPC UA, Ethernet
Power 100–240 V AC, 50/60 Hz; 70 W
Housing Powder-coated steel RAL 7035, IP65; options AISI 304L / 316L
Dimensions / weight 1140 × 600 × 350 mm; 75 kg
Explosion protection Class I, Division 2, Zone 2, Groups ABCD, T4; IECEx/ATEX housing options
Approvals cETLus, NFPA 496, UL 61010-1, CSA C22.2, UL 698A
User interface 7" Siemens HMI touchscreen

How to Order

Send Seven Star LLC an RFQ describing your water type, expected TOC level and area classification, and we will prepare a LAR QuickTOCuv offer with the right housing and options. The official LAR QuickTOCuv datasheet is attached to this page for download. For analyzers already in service we supply the LAR glass reactor for the UV method, the LAR 15 W ozone-free UV emitter and the LAR gas drying tube for the TOCUV carrier.

For difficult wastewater, see also the LAR QuickTOCultra high-temperature TOC analyzer.

Seven Star LLC is a trusted supplier with engineering support in Muscat for customers throughout Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet LAR QuickTOCuv Real-Time Online TOC Water Analyzer Datasheet (Process Insights) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

LAR Process Analysers is a German maker of online water analysers for TOC, COD, BOD, TNb and toxicity, founded in 1986 in Berlin by Dr. Werner Arts as a spin-off from the Technical University of Berlin. In 1989 it won a State of Berlin environmental technology award for the EloxMonitor online COD analyser. The company took its current name in October 2004 and has been part of Process Insights since 2018, with its headquarters still in Berlin.

Seven Star LLC sources and supplies LAR spare parts and consumables for operators in Oman who already run these analyzers. Current LAR analyzers are offered under the Process Insights name.

LAR Process Analysers company profile

Founded 1986, Berlin, Germany, by Dr. Werner Arts
Origin Spin-off from the Technical University of Berlin
Former name LAR Analytik & Umweltmesstechnik, renamed October 2004
Ownership Process Insights, since 2018
Measurement technology High-temperature combustion for TOC, TC, TOD, COD, BOD and TNb
Product families QuickTOC online TOC analysers, Elox COD analysers, TNb nitrogen analysers, BOD and toxicity monitors, laboratory TOC analysers

Milestones

  • 1986: LAR is founded in Berlin.
  • 1989: The EloxMonitor wins a Berlin environmental technology award.
  • 2004: The company becomes LAR Process Analysers AG.
  • 2018: LAR becomes part of Process Insights.

LAR analyzer spare parts listed here

Four of the listed items are parts for the UV persulfate oxidation analyzer type, the QuickTOCuv: a glass reactor for the UV method (501-40-000106, formerly 501-04-000021), a low-pressure 15 W ozone-free UV emitter (501-40-000159), a five-channel peristaltic pump (501-40-000215) and a gas drying tube for the carrier gas path (501-08-000045). All of them are wear or consumable parts replaced during routine upkeep.

LAR Process Analysers products we list

Family Examples
Liquid Analytical Accessories LAR 501-08-000045 Gas Drying Tube for Ca…, LAR 501-40-000106 Glass Reactor for UV M…, LAR 501-40-000159 UV Emitter Low Pressur…, LAR 501-40-000215 Peristaltic Pump 5-Cha…
Liquid Analytical Systems LAR NitriTox Online Toxicity Analyzer, LAR QuickCODultra Online COD (TOD) Analy…, LAR QuickTOCultra Online TOC Analyzer, LAR QuickTOCuv Online UV Persulphate TOC…

Ordering LAR parts: what we need

Send the LAR part number in the 501-xx-xxxxxx format, and the old number as well if your manual shows one. Add the analyzer type and serial number from the type plate, because the QuickTOCuv, QuickTOCultra and other models use different reactors, pumps and tubing. A photo of the old part and the manual's spare parts page speed up the check. We supply these parts to water, power and petrochemical sites across the GCC.

Facts checked against Process Insights' LAR announcement and German trade press, October 2026.

FAQ

Questions about the LAR QuickTOCuv Online UV Persulphate TOC Analyzer

Answers from our engineering team on installation, compatibility and integration.

01How does the LAR QuickTOCuv measure TOC?
The sample is mixed with sodium persulphate and oxidised in a UV reactor, where ultraviolet light converts organic carbon to CO2. A carrier gas carries the CO2 through a drying stage to an NDIR detector that measures it continuously, in line with DIN EN 1484 and US-EPA 415.2.
02Which water types is the QuickTOCuv intended for?
It is designed for pure water, boiler feed water, condensate return, drinking water, surface water and wastewater. LAR gives typical ranges of 100 to 1,000 ug/l in water-steam cycles and 1 to 50 mg/l in cooling water.
03How much maintenance does the QuickTOCuv need?
The analyzer auto-calibrates with a liquid standard and automatically checks the NDIR zero point and sensitivity. Routine maintenance involves consumables such as reagent, tubing and gas drying parts, and the reactor design protects the UV lamp for safe operation of over two years.
04Can the QuickTOCuv be installed in a classified area?
Yes. Purged and pressurised housings are available for Class I, Division 2, Zone 2, Groups A to D with temperature class T4, and ATEX and IECEx housing options are listed.
05Does Seven Star LLC supply the LAR QuickTOCuv in Oman?
Seven Star LLC supplies the LAR QuickTOCuv, its UV reactor glassware, UV emitters and other spare parts to customers in Oman and the GCC, with engineering support from Muscat.