Brand:

Rosemount 3051L Liquid Level Transmitter

Description

Overview

The Rosemount 3051L is Emerson’s flanged differential pressure level transmitter. The official data sheet explains that it combines the performance and capabilities of Rosemount 3051 transmitters with the reliability and quality of a direct mount seal in one model number, and that it offers a variety of process connections, configurations and fill fluid types to meet a breadth of level applications. The all-welded seal system removes the capillary joints, thread leaks and field assembly of a conventional wet-leg installation, making the 3051L a preferred option for tanks, vessels and columns with demanding fluids.

As a supplier of Rosemount products in Oman and the GCC, Seven Star LLC supplies the Rosemount 3051L Liquid Level Transmitter with the Rosemount 3051L datasheet and regional engineering support. Operators in Muscat, Sohar and Salalah can obtain the transmitter configured for the exact flange, extension and fill fluid in a single order.

Level Measurement Principle

The Rosemount 3051L measures hydrostatic head. A flanged seal mounted on the vessel nozzle transmits the pressure of the liquid column through a fill fluid to the 3051 sensor module. On an open tank the low side vents to atmosphere, while on a closed or pressurized vessel the low side connects to the vapor space or to a second seal through capillary. The sensor converts the differential pressure to a digital value, and the transmitter configurator can express it as level or volume. A built-in level configurator method guides the engineer through the setup, and it is available with options M6, BLE, D1, DA1, T9 or RK.

The fill fluid defines the temperature window of the seal. The data sheet lists silicone 200 from –45 to 205 °C, silicone 704 from 0 to 205 °C, SYLTHERM XLT from –75 to 145 °C, inert halocarbon from –45 to 160 °C, glycerin and water from –15 to 95 °C, Neobee M-20 from –15 to 205 °C and propylene glycol and water from –15 to 95 °C. Vacuum-grade silicone fills are also offered. Reference accuracy is 0.075 percent of span on ranges 2 to 4, and the QZ option quantifies total performance under real operating conditions.

Engineering Design of the Rosemount 3051L

The Rosemount 3051L pressure ranges are limited to three codes, range 2 at –250 to 250 inH2O, range 3 at –1000 to 1000 inH2O and range 4 at –300 to 300 psi, because the seal supplies the head rather than the sensor range. The high side flange is 2, 3 or 4 inch ASME B16.5 in Class 150, 300 or 600, or EN 1092-1 DN 50, DN 80 or DN 100, with JIS 10K to 40K options. Materials are carbon steel or 316 stainless steel flanges, with a 316L stainless steel, alloy C-276 or tantalum diaphragm. Extension lengths of 2, 4 and 6 inches (50, 100 and 150 mm) move the diaphragm clear of insulation or into the process.

The Rosemount 3051L low side can be a gauge connection or a differential flange adapter. A 2-inch Class 150 flush transmitter weighs 12.5 lb (5.7 kg) without options. Overpressure is limited to the flange rating or the sensor rating, whichever is lower, and flange ratings follow ASME B16.5 for Class 150, 300 and 600. The device offers 4 to 20 mA HART, low-power 1 to 5 Vdc HART, FOUNDATION Fieldbus, PROFIBUS PA and WirelessHART outputs, a back-lit graphical display, Bluetooth, the Loop Integrity diagnostic and safety certification options.

Key Features

The Rosemount 3051L brings integrated seals and transmitter engineering together. The features below are taken from the official data sheet.

  • Integrates the transmitter and direct mount seal in one model number, so the system is assembled, filled and calibrated at the factory.
  • Offers flush and extended diaphragms with 2, 3 and 4 inch flanges and a choice of 316L stainless steel, alloy C-276 or tantalum wetted parts.
  • Supports Tuned-System assemblies with a direct mount high side and capillary low side to cut installation cost and improve response.
  • Quantifies total system performance with the QZ option before the unit is purchased.
  • Provides a built-in level configurator that sets up level and volume measurement through a guided method.
  • Offers Bluetooth configuration, a back-lit graphical display and the Loop Integrity diagnostic.
  • Offers a choice of fill fluids including SYLTHERM XLT for cold service and silicone 704 for hot service.
  • Includes safety certification and proof testing options for SIL applications.

Industrial Applications

The Rosemount 3051L is used wherever a standard impulse line would plug, freeze, leak or require heat tracing. Typical Rosemount 3051L service includes crude and slop tanks, distillation columns and separators, boiler drums, chemical reactors, viscous or corrosive liquids and high temperature services that need a diaphragm seal. Because the seal is flush or extended at the nozzle, the transmitter can also be applied to slurries and fluids with suspended solids. In Oman these tasks are common in refineries, gas treatment, petrochemical units and storage terminals near Sohar and Salalah.

In Oman and the GCC, Seven Star LLC supplies the Rosemount 3051L to operators, EPC contractors and maintenance teams across Oman and the wider GCC. For other level technologies, compare the Rosemount 3051SAL liquid level transmitter, the Rosemount 5300 level transmitter and the general-purpose Rosemount 3051 pressure transmitter.

Technical Specifications

The table lists published Rosemount 3051L specifications from the Emerson DP level product data sheet dated March 2026.

Parameter Specification
Model Rosemount 3051L Liquid Level Transmitter
Pressure ranges Range 2: –250 to 250 inH2O; range 3: –1000 to 1000 inH2O; range 4: –300 to 300 psi
High side connection 2, 3 and 4 inch ASME B16.5 Class 150, 300, 600; DN 50, DN 80, DN 100 EN 1092-1; JIS
Extension lengths Flush; 2, 4 or 6 inch (50, 100, 150 mm) on 3 and 4 inch sizes
Diaphragm materials 316L stainless steel, alloy C-276, tantalum
Reference accuracy ±0.075% of span (ranges 2 to 4)
Output protocols 4–20 mA HART, 1–5 Vdc HART, FOUNDATION Fieldbus, PROFIBUS PA, WirelessHART
Fill fluids Silicone 200 and 704, SYLTHERM XLT, inert, glycerin and water, Neobee M-20, propylene glycol and water
Weight (2-inch Class 150, flush) 12.5 lb (5.7 kg) without options
Overpressure Flange rating or sensor rating, whichever is lower
Options QZ, Tuned-System (S1), DA1, BLE, M6 graphical display

Request a Quote for Rosemount 3051L

Request a formal quotation for the Rosemount 3051L Liquid Level Transmitter from Seven Star LLC. Provide the vessel nozzle size and rating, process fluid and temperature, fill fluid preference, output protocol and hazardous area approval, and our instrumentation division will return a valid model code with lead time. We can provide the Rosemount 3051L datasheet and confirm current availability and lead time. In Oman and the GCC, Seven Star LLC supplies level transmitters on request with local technical support for demanding tank and vessel measurements.

Datasheets & Documents
  • PDF Datasheet Emerson Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems Product Data Sheet 00813-0100-4016, Rev UD (covers 3051L), March 2026 Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 3051L Liquid Level Transmitter

Answers from our engineering team on installation, compatibility and integration.

01How does the Rosemount 3051L measure liquid level?
The Rosemount 3051L is a differential pressure transmitter with a direct mount seal on the high pressure side. The seal diaphragm sits at the vessel wall, so hydrostatic head from the liquid is transmitted through the fill fluid to the sensor, which converts the differential pressure to level, with the low side referenced to the vapor space or a second seal.
02What flange sizes and extensions are offered on the Rosemount 3051L?
High side connections are 2, 3 and 4 inch ASME B16.5 flanges or DN 50, DN 80 and DN 100 EN 1092-1 flanges, with JIS options. Diaphragms are available flush on all sizes and with 2, 4 or 6 inch extensions on 3 and 4 inch sizes, in 316L stainless steel, alloy C-276 or tantalum.
03What is a Tuned-System assembly?
A Tuned-System assembly uses a direct mount seal on the high side and a capillary remote seal on the low side. The data sheet states it can reduce installation costs by 20 percent, improve performance by up to 30 percent and increase response time by up to 80 percent compared with a balanced capillary system.
04Can I check total system performance of the Rosemount 3051L?
Yes. Option code QZ provides an up-front quantified performance report for the total seal system under operating conditions, helping engineers confirm that a level transmitter will meet accuracy and response requirements before it is purchased.
05Is Seven Star LLC a trusted supplier for Rosemount products?
Yes. Seven Star LLC is a trusted supplier for Rosemount in Oman and the GCC and supplies the Rosemount 3051L with the manufacturer datasheet and local technical support. Send your vessel connection, fill fluid and range data for a formal quotation.