Brand:

Siemens SITRANS FM MAG 5100W Electromagnetic Flowmeter

Description

Overview: A Dedicated Sensor for Every Water Application

The Siemens SITRANS FM MAG 5100W is an electromagnetic flow sensor purpose-built for ground water, drinking water, wastewater, sewage, and sludge applications, available across an exceptionally wide sensor diameter range from 1/2 inch to 78 inch. Rather than being a general-purpose flow sensor adapted for water duty, the MAG 5100W’s patented hard rubber (NBR or ebonite) or EPDM liners are specifically engineered for water and wastewater service, including drinking water applications requiring special regulatory approvals.

As an authorized supplier of Siemens process instrumentation, Seven Star LLC sources and supplies the SITRANS FM MAG 5100W to water authorities, wastewater treatment plants, and industrial water users across Oman and the wider GCC. Because the MAG 5100W sensor must be paired with a separately ordered MAG 5000 or MAG 6000 transmitter to form a complete flowmeter, Seven Star LLC helps engineering teams specify the correct sensor-transmitter combination for their custody transfer, leak detection, or general water metering application.

Measurement Principle

The MAG 5100W measures flow based on Faraday’s law of electromagnetic induction: as electrically conductive water flows through the sensor’s magnetic field, a voltage is induced across the flow that is proportional to the fluid’s velocity, sensed by electrodes and amplified by an input circuit with extremely high impedance (greater than 10^14 Ω), allowing accurate measurement even on fluids with conductivity as low as 5 µS/cm. Because the measurement depends only on fluid velocity and conductivity, temperature, pressure, density, and viscosity have no influence on the result.

The sensor’s coned liner (octagon) design on smaller sizes (DN15-40) delivers increased low-flow accuracy specifically valuable for water leak detection applications, where a conventional flowmeter’s low-flow measurement uncertainty would mask the small, continuous losses characteristic of a leaking distribution main. Independent testing by Force Certification has verified the MAG 5100W can be installed in zero-diameter upstream and downstream straight-run pipe configurations while maintaining 0.8% accuracy, a significant installation flexibility advantage over flowmeters requiring long straight pipe runs.

Engineering Design of the MAG 5100W

The sensor is supplied as standard to IP67 per EN 60529 (NEMA 4X/6), with IP68 per EN 60529 (NEMA 6P) available as an ordering option where the meter will be buried, chambered below grade or permanently immersed, with integrated grounding electrodes eliminating the need for separate grounding rings in many installations and reducing installation time and material cost. SensorProm technology stores critical sensor-specific calibration data and automatically passes it to the connected transmitter, so if the transmitter ever needs replacement, the new unit uploads all previous settings and resumes measurement without reprogramming or rewiring – a plug-and-play, hot-swappable design that minimizes service downtime.

The MAG 5100W is approved for custody transfer under MI-001 for cold water in sizes DN 50 to DN 1200, with appropriate labeling applied at the specified Q3/Q3-Q4 and Q2/Q1 measuring range ratios, and carries Kiwa water approval (NL) over the same DN 50 to DN 1200 band. The sensor is catalogued under two article families – 7ME6520 with EPDM or NBR liner and 7ME6580 with ebonite liner – and the size ceiling differs between them, so the article number and nominal size must be confirmed together when specifying a large-diameter meter. The sensor connects to either the cost-efficient MAG 5000 transmitter (±0.4% accuracy) or the MAG 6000/6000 I transmitter, which adds bus communication (HART, PROFIBUS DP/PA, FOUNDATION Fieldbus H1, DeviceNet), batch function, and improved ±0.2% accuracy, with the MAG 6000 I offered in an aluminum enclosure with Ex approvals for hazardous-area installation.

Key Features

The Siemens SITRANS FM MAG 5100W delivers dedicated, reliable water and wastewater flow measurement. Key characteristics include:

  • Sensor diameter range from 1/2 inch to 78 inch.
  • Patented NBR/ebonite or EPDM liners specific to water applications; EPDM liner suitable for drinking water.
  • IP67 to EN 60529 / NEMA 4X/6 as standard, with optional IP68 (NEMA 6P) for underground, submerged, or underwater installation.
  • Zero-diameter upstream/downstream installation capability at 0.8% accuracy (independently verified).
  • Custody transfer approval (MI-001) on article 7ME6520.
  • SensorProm technology for plug-and-play, hot-swappable transmitter replacement.
  • Coned liner design for increased low-flow accuracy in leak detection applications.

Industrial Applications

The MAG 5100W is deployed across water abstraction points, water distribution networks, wastewater and sludge handling systems, and custody transfer water or cooling metering stations. Its IP68 rating and zero-diameter installation flexibility make it particularly suited to buried distribution main metering and leak detection programs where conventional flowmeter installation requirements would be impractical.

Seven Star LLC supports water authorities, wastewater treatment plants, and industrial water users across Oman, Muscat, Sohar, and the broader GCC region with sourcing of Siemens SITRANS FM MAG 5100W sensors, helping projects achieve accurate, dependable water flow measurement.

Liner Selection, Materials and Water Approvals

Liner choice is the decision that most often determines whether a Siemens SITRANS FM MAG 5100W gives trouble-free service or becomes a maintenance item, and Siemens catalogues the sensor with two distinct liner routes. The 7ME6520 article family is offered with EPDM or NBR, while the 7ME6580 family is built with ebonite. Both are rated for a medium temperature of −10 to +70 °C, which comfortably covers potable distribution, treated effluent and abstraction duty, though it rules the sensor out of hot process water service above that ceiling. Ambient rating is considerably wider at −40 to +70 °C, so summer chamber temperatures in the interior of Oman are well inside the envelope.

Measuring and grounding electrodes are Hastelloy C276, chosen for its resistance to the chloride-bearing and mildly aggressive waters common in coastal abstraction and in treated wastewater streams. For drinking water duty the sensor carries the approval set that Gulf water authorities and their consultants normally ask to see on a tender submission: WRAS, NSF/ANSI Standard 61, ACS listing, DVGW W270 and Belgaqua. Pressure ratings are size-dependent, running from 0.01 to 40 bar on the smallest DN 15 to DN 40 bodies down to 0.01 to 16 bar across DN 350 to DN 1200, so flange rating and line pressure should be checked against the specific nominal size rather than assumed from the family.

Installation Practice in Omani Water Networks

The practical value of the integrated grounding electrodes shows up on site rather than on the datasheet. On a lined ductile iron or plastic main, a conventional magmeter needs separate grounding rings to establish a reference potential for the electrode signal, which adds two more gasketed joints, two more parts to procure in the correct material, and two more opportunities for a leak path at commissioning. Building that reference into the sensor removes all of it, which matters most on buried chamber installations where the joint being avoided is one nobody wants to revisit.

Where the meter is destined for a below-grade chamber that floods, or for direct burial, the IP68 ordering option should be specified at the point of purchase rather than assumed. It is not the default build. Seven Star LLC routinely checks this detail with water authority and contractor clients across Muscat, Sohar and Salalah before a purchase order is raised, because an IP67 sensor delivered for a duty that required IP68 is a problem discovered at the worst possible time – after the chamber has been backfilled.

Technical Specifications

The table below summarizes the core specifications of the Siemens SITRANS FM MAG 5100W as supplied by Seven Star LLC.

n

n

n

n

n

n

ParameterSpecification
ModelSITRANS FM MAG 5100 W (article families 7ME6520 and 7ME6580)
TypeElectromagnetic flow sensor for water applications
Diameter Range1/2 inch to 78 inch (DN15 to DN2000)
Liner MaterialNBR/ebonite or EPDM (patented)
Protection RatingIP67 to EN 60529 / NEMA 4X/6 standard; IP68 (NEMA 6P) optional
Accuracy0.8% (zero-diameter install); up to ±0.2% with MAG 6000 transmitter
Compatible TransmittersMAG 5000, MAG 6000, MAG 6000 I
CertificationMI-001 cold water custody transfer, DN 50 to DN 1200; Kiwa (NL) DN 50 to DN 1200
Electrode MaterialHastelloy C276 measuring and grounding electrodes
Medium Temperature−10 to +70 °C (NBR and EPDM liners)
Ambient Temperature−40 to +70 °C
Pressure Rating0.01 to 40 bar (DN 15–40); 0.01 to 16 bar (DN 350–1200)
Drinking Water ApprovalsWRAS, NSF/ANSI 61, ACS, DVGW W270, Belgaqua
Article Families7ME6520 (EPDM or NBR liner); 7ME6580 (ebonite liner)
Communication (via MAG 6000)HART, PROFIBUS DP/PA, FOUNDATION Fieldbus H1, DeviceNet

Request a Quote for Siemens SITRANS FM MAG 5100W Electromagnetic Flowmeter

Seven Star LLC supplies the Siemens SITRANS FM MAG 5100W electromagnetic flowmeter with full manufacturer documentation and regional technical support. Contact our instrumentation division for a formal B2B quotation, to confirm the correct sensor size and transmitter pairing for your water application, or to obtain the complete technical datasheet. Seven Star LLC ensures every unit shipped across Oman and the GCC is genuine Siemens hardware, correctly specified, and backed by local support.

Related Products

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Siemens SITRANS FM MAG 5100W Electromagnetic Flowmeter”

Your email address will not be published.Required fields are marked *

About brand
Siemens is a global leader in industrial automation, power distribution, and process control. Their portfolio spans PLCs (SIMATIC series), distributed I/O, drives, HMIs, industrial Ethernet, and legacy APACS/QUADLOG modules—trusted across factories, utilities, oil & gas, and critical infrastructure. Siemens solutions deliver reliable performance, easy integration with modern SCADA and DCS systems, and long-term support for legacy installations. Seven Star LLC supplies genuine Siemens components, validates compatibility for replacements or upgrades, and provides documentation to ensure smooth commissioning and compliance.

Click to view complete Siemens information.

Frequently Asked Questions

Does the MAG 5100W need a separate transmitter?
Yes, the MAG 5100W is a flow sensor that must be combined with a separately ordered MAG 5000, MAG 6000, or MAG 6000 I transmitter to form a complete flowmeter.
What size range does the MAG 5100W cover?
The sensor is available in diameters from 1/2 inch to 78 inch, covering everything from small service connections to large distribution mains.
Can the MAG 5100W be installed underground or underwater?
Yes, the sensor is rated IP68, supporting permanent immersion, underwater installation, and burial in the ground.
Is the MAG 5100W suitable for custody transfer?
Yes, article 7ME6520 carries MI-001 custody transfer approval, with appropriate labeling for the certified measuring range ratios.
Does Seven Star LLC supply this part across the GCC?
Yes, Seven Star LLC sources and supplies the Siemens SITRANS FM MAG 5100W to water authorities and industrial water users across Oman and the wider GCC region.