- Automation & ControlView all 2,897 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Siemens
Siemens Maxum II 2-Cell Filament Detector Repair Kit 2020379-701
Description
Overview: Restoring Filament Detector Performance Without Full Replacement
The Siemens Maxum II 2-Cell Filament Detector Repair Kit, part number 2020379-701, provides the internal components needed to restore a degraded 2-cell filament thermal conductivity detector (TCD) on the Siemens Maxum Edition II process gas chromatograph without requiring a full detector assembly replacement. This repair kit is the maintenance counterpart to the complete filament detector assembly, allowing analyzer technicians to service an existing detector body when only the internal filament elements or seals have degraded.
As an independent specialized supplier of Siemens Maxum Edition II analyzer spare parts, Seven Star LLC sources and supplies the 2-cell filament detector repair kit 2020379-701 to refineries, gas plants, and petrochemical complexes across Oman and the wider GCC. Stocking this kit alongside the complete detector assembly gives maintenance teams the flexibility to choose the most cost-effective repair path for each TCD fault.
Working Principle: Filament Element Renewal
A 2-cell filament TCD relies on two precisely matched heated filament elements – one reference cell and one measurement cell – whose relative resistance change in response to carrier gas thermal conductivity forms the basis of the detector’s signal. Over time and repeated thermal cycling, filament elements can drift out of calibration balance, develop contamination, or fail outright, degrading the detector’s baseline stability and sensitivity even though the surrounding detector body and electrical connections remain serviceable.
The repair kit provides the internal parts – filament elements and associated sealing hardware – needed to renew the detector’s sensing function while reusing the existing detector body, feed-through connections, and oven mounting. This targeted repair approach restores the detector’s thermal-conductivity measurement accuracy without the cost and downtime of a full assembly swap, provided the detector body itself has not suffered mechanical damage.
Engineering Design of the Repair Kit
The 2020379-701 kit is packaged as a complete set of the wear and consumable components inside the 2-cell filament TCD, sized and specified to match the current-generation filament detector assembly used on the Maxum Edition II. Because filament elements must be closely matched to maintain balanced Wheatstone-bridge measurement behavior, the kit supplies factory-matched components rather than individual filaments sourced separately.
Installation follows the same detector-opening procedure used for full assembly service – the analyzer must be fully de-energized and cooled before the TCD housing is opened, and care must be taken to avoid contaminating or scratching the machined sensing surfaces during the filament replacement, following the manufacturer’s documented procedure.
Key Features
The 2-Cell Filament Detector Repair Kit 2020379-701 provides a cost-effective path to restoring TCD performance. Key characteristics include:
- Complete set of factory-matched filament elements and sealing hardware for 2-cell filament TCD renewal.
- Enables detector repair without replacing the full assembly when the detector body remains serviceable.
- Restores balanced reference/measurement cell behavior for accurate thermal conductivity measurement.
- Compatible with the current-generation Maxum Edition II 2-cell filament detector configuration.
- Genuine Siemens Maxum II part number for correct fit and calibration compatibility.
Industrial Applications
The repair kit is used during scheduled TCD maintenance and in response to detector baseline drift or sensitivity loss on Maxum Edition II analyzers configured with a 2-cell filament detector, whether used for general process gas analysis or as an inter-column detector alongside an FID or FPD channel. Maintaining ready access to this kit allows analyzer maintenance teams to service filament detector faults during a single planned outage rather than waiting on a full assembly replacement.
Seven Star LLC supports refinery instrumentation teams, gas processing operators, and petrochemical maintenance departments across Oman, Muscat, Sohar, and the broader GCC region with sourcing of Maxum Edition II detector repair hardware, helping analyzer houses manage both cost and downtime during TCD servicing.
Technical Specifications
The table below summarizes the core specifications of the Siemens Maxum II 2-Cell Filament Detector Repair Kit as supplied by Seven Star LLC.
| Parameter | Specification |
|---|---|
| Model / Part Number | 2-Cell Filament Detector Repair Kit, P/N 2020379-701 |
| Detector Type | Thermal Conductivity Detector (TCD), 2-cell filament |
| Kit Contents | Factory-matched filament elements and sealing hardware |
| Use Case | In-place detector repair without full assembly replacement |
| Target Platform | Siemens Maxum Edition II Process Gas Chromatograph |
| Hardware Condition | New, genuine Siemens part number |
Why Choose Seven Star LLC for Maxum II TCD Repair Kit Sourcing
Deciding between a filament repair kit and a full detector assembly replacement is a real cost-and-downtime judgment call – the repair kit only restores performance correctly when the detector body and feed-through connections are still mechanically sound, and using it on a body with underlying damage wastes the repair labor without solving the actual fault. Seven Star LLC’s sourcing team discusses the specific TCD symptoms (baseline drift, sensitivity loss, or outright failure) with the customer before recommending the repair kit over a full assembly, helping analyzer technicians choose the more cost-effective path for each specific fault rather than defaulting to the more expensive option. We also help refinery and gas plant maintenance departments across Oman keep both the repair kit and the full assembly in a planned spares strategy, and coordinate delivery so a TCD fault can be resolved within a single planned outage rather than a multi-visit repair.
Request a Quote for Siemens Maxum II 2-Cell Filament Detector Repair Kit 2020379-701
Seven Star LLC is a dedicated supplier of Siemens Maxum Edition II process gas chromatograph spare parts and detector repair kits throughout Oman and the GCC. To request a formal B2B quotation, verify current availability and lead time, or confirm compatibility of the 2-Cell Filament Detector Repair Kit 2020379-701 with your specific Maxum II configuration, contact our instrumentation sourcing team today.
Related Products
- LAR 501-40-000159 UV Emitter Low Pressure 15W Ozone Free Tubular
- AMETEK 16052JE-MIRROR Protected Gold Mirror
- Siemens Maxum II Filament Detector 2-Cell Assembly 2021335-001
- Honeywell SR-X2V Replacement Oxygen Sensor
- LAR 501-40-000106 Glass Reactor for UV Method (Old P/N: 501-04-000021)
- Siemens Maxum II Veriflow Air-Actuated Valve 1671004-103
Datasheets & Documents
- Instruction Manual Siemens Maxum II 2-Cell Filament Detector Repair Kit 2020379-701 Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Siemens is the German technology group whose industrial products include SIMATIC controllers and HMIs, SINAMICS drives, SIRIUS and SENTRON switching and protection devices, SIPROTEC protection relays, SITRANS process instruments, SCALANCE networks and process analysers. It was founded in Berlin on 12 October 1847 by Werner von Siemens and the precision mechanic Johann Georg Halske as Telegraphen-Bauanstalt von Siemens & Halske, to build Siemens's newly designed pointer telegraph. Siemens AG is headquartered in Munich and listed on the Frankfurt Stock Exchange; its energy business was spun off as Siemens Energy in 2020.
Siemens company profile
| Founded | 12 October 1847, Berlin, Germany, as Telegraphen-Bauanstalt von Siemens & Halske, with 10 employees |
|---|---|
| Founders | Werner von Siemens (1816–1892) and Johann Georg Halske (1814–1890) |
| First product | The pointer telegraph designed by Werner von Siemens |
| Headquarters | Munich, Germany (Siemens AG) |
| Ownership | Public company listed in Frankfurt; Siemens Energy (2020) and Siemens Healthineers are separately listed companies |
| Businesses acquired that appear in our range | Moore Products (bought in 2000; APACS and QUADLOG control systems), Applied Automation (Maxum process gas chromatographs); small industrial gas turbines such as the SGT-300 came with Alstom's industrial turbine business in 2003 |
| Product families | SIMATIC S7 PLCs, ET 200 distributed I/O and HMI panels, TIA Portal software, SINAMICS drives, SIMOTICS motors, SIRIUS and SENTRON low voltage devices, SIVACON switchboards, SIPROTEC relays, SITRANS instruments, SCALANCE network components, building technology valves and sensors |
Milestones
- 1847: Siemens & Halske starts work in Berlin with 10 employees.
- 1848: The company wins the contract for Europe's first long-distance telegraph line, Berlin to Frankfurt am Main.
- 1856: 330 employees, two-thirds of them working on telegraph networks in Russia.
- 1866: Werner von Siemens describes the dynamo-electric principle, the basis of the electric generator.
- 1958 onwards: The SIMATIC name is used for Siemens industrial automation; S7 PLCs follow in the 1990s and S7-1500 in 2012.
- 2020: Siemens Energy is spun off and listed separately.
Choosing Siemens automation products
A Siemens order number (MLFB) identifies the exact product: 6ES7 is SIMATIC automation, 6AV is HMI, 6GK is industrial communication, 6SL is SINAMICS drives, 3R is SIRIUS control and 5SY is SENTRON miniature circuit breakers. For PLCs, S7-1200 is the compact controller for small machines, S7-1500 is the current mid-to-high range controller, and S7-300 and S7-400 are older platforms still running in many plants; S7-300 is being phased out, so spares and migration to S7-1500 are common requests. When replacing a CPU or module, the full order number including the version digits matters, because firmware and hardware versions affect compatibility with the existing project.
Where Siemens products are used
In Oman and the GCC, Siemens automation runs in oil and gas, power and desalination plants, water networks, cement and process industries. Maxum gas chromatographs analyse gas composition in gas plants and refineries, SIPROTEC relays protect substations, SGT-300 turbines drive generators and compressors, and Siemens building valves are used in HVAC systems.
Siemens products we list
| Family | Examples |
|---|---|
| SIMATIC controllers and I/O | S7-1500, CPU 1515-2 PN, S7-1200, CPU 1214C, S7-300, S7-400H CPU 412-5H, ET 200SP, IM 153-2 |
| HMI and networking | KTP700 Basic, TP700 Comfort, TP1200 Comfort, SCALANCE XC208, SCALANCE WAM766, PROFIBUS OLM |
| Drives, motors and power distribution | SINAMICS G120C, SINAMICS G120X, 1LA7 motor, SIVACON S8, SIPROTEC 7SJ85, 5SY4510-7 MCB |
| Process instruments | SITRANS P320, MAG 5100W, SITRANS TH320, SITRANS TS500, SITRANS TR200 |
| Maxum II analyser spares | FID 302A detector, FPD II assembly, filament detector, Model 50 valve, SYSCON kit, air bath heater |
| APACS and QUADLOG spares | QLCCM24AAN, QLSAMBAN, QLSDM024DCCBN, 39SAMCAN, 16137-151 M-BUS cable |
| Building technology | VPI46 PICV, VPF44, QFM1660 sensor |
Ordering Siemens products: what we need
Send the full order number from the label (for example 6ES7214-1AG40-0XB0) and, for PLC and HMI parts, the hardware and firmware version (FS and V numbers). For Maxum II and APACS spares, send the Siemens part number such as 2021651-002. For drives, add the motor power and supply voltage.
Frequently requested Siemens models: Siemens IM 155-6 PN ST ET 200SP Interface Module 6ES7155-6AU02-0BN0, Siemens SGT-300 Industrial Gas Turbine.
Facts checked against Siemens's published history timeline, October 2026.
FAQ
Questions about the Siemens Maxum II 2-Cell Filament Detector Repair
Answers from our engineering team on installation, compatibility and integration.
01What does the 2020379-701 repair kit contain?
The kit contains factory-matched filament elements and sealing hardware needed to renew a 2-cell filament TCD without replacing the full detector assembly.
02When should this kit be used instead of a full detector replacement?
It is used when the detector body and electrical connections remain serviceable but the internal filament elements have drifted, become contaminated, or failed, offering a lower-cost repair path.
03Why must the filament elements be factory-matched?
The 2-cell TCD relies on balanced Wheatstone-bridge behavior between the reference and measurement filaments, so mismatched elements would compromise measurement accuracy.
04What precautions apply when installing this kit?
The analyzer must be fully de-energized and cooled before opening the TCD housing, and the machined sensing surfaces must be handled carefully to avoid contamination or scratching.
05Does Seven Star LLC supply this part across the GCC?
Yes, Seven Star LLC sources and supplies the Siemens Maxum II 2-Cell Filament Detector Repair Kit 2020379-701 to refinery, gas processing, and petrochemical customers across Oman and the wider GCC region.


















Reviews