VEGA VEGATOR 141 Level Controller for 4-20 mA Sensors
Description
A single-channel limit alarm for any 4…20 mA level or pressure sensor
The VEGATOR 141 is a single-channel controller for level detection with sensors that deliver an analogue 4…20 mA signal, such as capacitive electrodes, hydrostatic pressure transmitters or process pressure transmitters. VEGA names pump control (on/off) and monitoring functions such as overfill and dry-run protection as typical applications. The module is mounted on a 35 mm carrier rail, powers an active sensor itself or accepts a passive one with its own supply, and drives an operating relay as limit alarm with an optional active fail-safe relay. The signal circuit is monitored permanently for line break and short-circuit, and the signal can come from a hazardous area.
Technical specifications
| Parameter | Specification |
|---|---|
| Type | VEGATOR 141, single-channel controller for 4…20 mA sensors |
| Series | Module unit for carrier-rail mounting, 35 x 7.5 mm rail acc. to EN 50022/60715, detachable coded terminals |
| Operating voltage | 24…230 V AC (-15 %, +10 %), 50/60 Hz; 24…65 V DC |
| Max. power consumption | 2 W (8 VA) |
| Input | 1 x 4…20 mA, active (sensor powered by VEGATOR 141) or passive (selectable) |
| Terminal voltage, idle | 18.2 V DC ± 5 % |
| Internal resistance | 200 Ω (active input), 100 Ω (passive input) ± 1 % |
| Current limitation | 23 mA, permanently short-circuit proof |
| Fault detection | Line break ≤ 3.6 mA; short-circuit ≥ 21 mA |
| Switching threshold | Adjustable in the range 4…20 mA |
| Relay output | 1 operating relay + 1 optional fail-safe relay; floating SPDT contacts |
| Contact rating | 10 mV DC min.; max. 253 V AC / 50 V DC; 3 A AC / 1 A DC; max. 500 VA, 54 W DC |
| Switch-on/off delay | 150 ms basic (± 10 %); adjustable 2 / 6 / 8 s (± 20 %) |
| Ambient temperature, protection | -20…+60 °C; IP20; overvoltage category per IEC 61010-1; pollution degree 2 |
Pump control and dry-run protection
Because the switching threshold is adjustable anywhere between 4 and 20 mA, one VEGATOR 141 can turn a continuous transmitter into a switch: set the threshold to the level at which a pump should start, and use the adjustable delay of 2, 6 or 8 s to avoid chatter on waves or turbulent surfaces. The optional second relay gives an active fault signal, so a controller can distinguish between a genuine low level and a failed sensor or cable.
Selecting and ordering
Choose the VEGATOR 141 when the sensor outputs 4…20 mA; the VEGATOR 121 serves vibrating switches with 8/16 mA signals, and the VEGATRENN 141 is an Ex separator for HART sensors. The two supply ranges (AC 24 to 230 V, DC 24 to 65 V) allow one module for most control cabinets. Per VEGA, the technical data in the safety instructions apply for approved instruments and may differ from the sheet, so specify any Ex requirement, the relay quantity and the sensor type in your RFQ and confirm the approval marking with VEGA.
When specifying, list the sensor type, its supply requirement and the number of loops, because a single-channel controller serves one measuring point and a second point needs a second module on the rail. Cabinet builders usually add a separate fuse and terminal block per loop. Confirm the relay load and the supply voltage printed on the sheet against your control circuit before ordering.
Related VEGA products: VEGA VEGAMET 841 Field Level Controller, VEGA VEGATRENN 141 Ex Separator for 4-20 mA HART Sensors and VEGA VEGATOR 121 Controller for 8/16 mA Vibrating Switches.
Active or passive sensor input
VEGA’s specification sheet shows that the VEGATOR 141 input can be set up in two ways. With the active input, the controller supplies the two-wire 4…20 mA sensor itself; the internal resistance is 200 Ω and the terminal voltage in the idle state is 18.2 V DC. With the passive input, the sensor has its own supply and the internal resistance is 100 Ω. The input current is limited to 23 mA and is permanently short-circuit proof. Typical sensors are capacitive electrodes, hydrostatic pressure transmitters and process pressure transmitters, and VEGA notes that the signal can also come from a hazardous area.
Line monitoring and fault signalling
The signal circuit is permanently monitored. A current of 3.6 mA or less is detected as a line break, and 21 mA or more as a short circuit, so a cut cable or failed sensor cannot be mistaken for a normal level. Besides the fault indication on the unit, an optional fail-safe relay can provide an active fault signal to the control system.
Relay contacts and switching delay
The operating relay is a floating changeover contact (SPDT). It can switch from 10 mV DC / 10 µA up to 253 V AC or 50 V DC, with a maximum current of 3 A AC or 1 A DC and a breaking capacity of up to 500 VA or 54 W DC. This is enough to drive a pump contactor coil directly. The switch-on and switch-off delay has a basic value of 150 ms and can be set to 2, 6 or 8 s, which helps prevent rapid pump cycling on turbulent surfaces. The switching threshold is adjustable anywhere in the 4…20 mA range.
Mounting and supply
The unit mounts on a 35 × 7.5 mm carrier rail to EN 50022/60715, with detachable coded terminals for wires from 0.25 to 2.5 mm². It accepts 24…230 V AC (50/60 Hz) or 24…65 V DC with a maximum consumption of 2 W (8 VA), operates at −20 to +60 °C and has IP20 protection, so it is installed inside a control cabinet.
Documents and quotation
The official VEGA VEGATOR 141 specification sheet (46842-EN, version 250605) is attached to this page for download and covers the technical data, dimensions and wiring summarised above.
Send Seven Star LLC your tag list, process medium, vessel geometry, required approvals and quantity and we will prepare a quotation from our Muscat office. We are an independent supplier; more level instrumentation is listed on our site. Confirm the final order code and approval marking with the manufacturer before ordering.
Datasheets & Documents
- Datasheet VEGA VEGATOR 141 Specification Sheet (46842-EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
VEGA is a German maker of level and pressure instruments. Bruno Grieshaber founded the company in 1959 in Triberg in the Black Forest, and it has been based in Schiltach since 1975, still family owned as VEGA Grieshaber KG. VEGA is best known for radar level sensors: it introduced the first two-wire radar level sensor in 1997 and the first 80 GHz radar sensor for bulk solids, the VEGAPULS 69, in 2015.
Seven Star LLC is an independent supplier listing VEGA radar and guided wave radar transmitters, point level switches, pressure transmitters and signal conditioning instruments for buyers in Oman and the GCC. Sensors are matched from the product code on the type label.
VEGA at a glance
| Origin | Founded by Bruno Grieshaber in 1959 in Triberg, Germany |
|---|---|
| Headquarters | Schiltach, Black Forest, Germany (since 1975) |
| Ownership | Family-owned company: VEGA Grieshaber KG |
| Milestones | First two-wire radar level sensor (1997), first 80 GHz radar for bulk solids, VEGAPULS 69 (2015), VEGAPULS 6X single radar platform for liquids and solids |
| Product families | VEGAPULS radar, VEGAFLEX guided wave radar, VEGASWING and VEGAPOINT switches, VEGACAL capacitive probes, VEGABAR and VEGADIF pressure, VEGAMET and VEGADIS signal conditioning |
VEGA sensor and instrument series
| Series | Type | Typical use |
|---|---|---|
| VEGAPULS 6X, VEGAPULS 69, VEGAPULS 64 | Process radar level transmitters (80 GHz) | Storage and process tanks, reactors with agitators, silos and bulk solids |
| VEGAPULS 11, 21, 31, 42 | Compact radar sensors | Water and wastewater, simple storage tanks; VEGAPULS 42 with IO-Link for machine integration |
| VEGAPULS C 21, C 11, C 22, C 23 | Radar sensors with fixed cable, IP68 | Wet wells, pumping stations, open channels and river levels |
| VEGAFLEX 81, 82, 83, 86 | Guided wave radar (TDR) | Level and interface in liquids, bulk solids, hygienic and high-temperature or high-pressure service (VEGAFLEX 86) |
| VEGASWING 61, 63, VEGAPOINT 21 | Vibrating and capacitive point level switches | Overfill protection, dry-run protection and high or low level alarms |
| VEGACAL 62 to VEGACAL 67 | Capacitive rod and cable probes | Point and continuous level in solids and conductive or adhesive liquids |
| VEGABAR 82, 83, 28, 29, 38 | Pressure transmitters, ceramic or metallic cell | Process pressure and hydrostatic level; compact 18/19 and 28/29/38 versions for utilities |
| VEGADIF 85 | Differential pressure transmitter | DP flow, filter monitoring and level in pressurised vessels |
| VEGAMET 841, VEGADIS 176 | Controller and loop display | Level display, pump control and remote indication of 4-20 mA signals |
Where VEGA instruments are used
VEGA radar sensors measure level in crude oil and product tanks, separators, chemical reactors, cement and aggregate silos, grain stores and water reservoirs. Compact cable radars are widely used in wastewater pumping stations and flood monitoring. Because 80 GHz radar focuses a narrow beam, it can measure past internal structures in a tank, and it is not affected by the temperature, pressure or vapour above the product, which suits hot Gulf storage tanks.
Ordering VEGA instruments: what we need
The product code on the type label (for example PS64.XXXXXXX) fixes the measuring range, antenna or probe, process connection, electronics and approvals. Send it with the serial number. For a new measurement add the medium and its dielectric constant if known, tank or silo height and internals, process pressure and temperature, process connection, output (4-20 mA HART, PROFIBUS PA, Modbus or IO-Link), and any hazardous-area or overfill protection approval required.
Facts checked against VEGA company and product information, October 2026.
Browse VEGA products by category: Level Transmitter, Pressure Instrumentation, Controllers and Data Acquisition.
FAQ
Questions about the VEGA VEGATOR 141 Level Controller for 4-20 mA
Answers from our engineering team on installation, compatibility and integration.
01What does the VEGATOR 141 do?
It evaluates a 4…20 mA level or pressure sensor signal and switches a limit relay, with line-break and short-circuit monitoring.
02Can it power the sensor?
Yes, the input is selectable as active (powered by the VEGATOR) or passive.
03What supply does it need?
24…230 V AC or 24…65 V DC.
04What are the relay delays?
A 150 ms basic delay or an adjustable 2, 6 or 8 s.
05How is it mounted?
On a 35 x 7.5 mm carrier rail with detachable coded terminals.