- Automation & ControlView all 2,810 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: VEGA
VEGA VEGAPULS 62 Radar Level Sensor 160 bar 450 C
Description
The VEGAPULS 62 in brief
If one radar had to cover most liquid tanks in a refinery or gas plant, the VEGA VEGAPULS 62 is the sort of sensor VEGA describes: a universal device for continuous level measurement of liquids, used in storage containers, reactors and process vessels even when conditions are difficult. The antenna versions and material choices are what make it so, ranging from PTFE, PP and PEEK to 316L, Alloy C22, Alloy 400 and a stainless precision-cast part. The wide pressure and temperature window simplifies project planning, because one model can serve many vessels.
Technical limits are generous: -1 to +160 bar, -196 to +450 °C, measuring range up to 35 m (114.8 ft), and a 2 mm deviation. The measurement stays independent of pressure, temperature, gas and steam, according to the data sheet.
Selection logic for VEGAPULS 62
Process connection. Choose a G1½ or 1½ NPT thread, or a flange from DN 40 (1½ in).
Wetted material and seal. 316L is the default metal; Alloy C22 (2.4602), Alloy 400 (2.4360) or stainless precision casting 1.4848 handle chlorides, acids and heat; PTFE, PP or PEEK serve corrosive media. Seals are FKM, FFKM or graphite.
Electronics. 4 to 20 mA/HART two-wire or four-wire, Profibus PA, Foundation Fieldbus, Modbus with Levelmaster protocol, and a HART version with integrated accumulator.
VEGAPULS 62 technical specifications
Figures are from the 4 to 20 mA/HART two-wire specification sheet.
| Parameter | Value (datasheet) |
|---|---|
| Model | VEGAPULS 62, universal radar level sensor for liquids |
| Measuring range up to | 35 m (114.8 ft) |
| Deviation | 2 mm |
| Process fitting | Thread from G1 1/2; 1 1/2 NPT; flanges from DN 40, 1 1/2 in |
| Process pressure | -1 to +160 bar (-100 to +16000 kPa / -14.5 to +2320 psig) |
| Process temperature | -196 to +450 C (-321 to +842 F) |
| Ambient, storage, transport temperature | -40 to +80 C |
| Operating voltage | 9.6 to 36 V DC |
| SIL qualification | Optionally up to SIL2 |
| Wetted materials | 316L, Alloy C22 (2.4602), Alloy 400 (2.4360), stainless steel precision casting (1.4848), PTFE, PP, PEEK |
| Process seal | FKM, FFKM or graphite |
| Housing | Single or double chamber; plastic, stainless steel or aluminium; up to IP 68 (1 bar) |
| Electronics | HART two-wire and four-wire, Profibus PA, Foundation Fieldbus, Modbus, HART with accumulator |
| Datasheet reference | 34496-EN-160119 |
Typical duties for VEGAPULS 62 in oil, gas, power and water
In upstream and midstream installations, the VEGAPULS 62 can measure separator liquid levels, condensate drums, crude and product storage, and amine or glycol tanks, subject to the vessel conditions staying inside the data sheet limits. In power plants, it covers feedwater tanks, hot-condensate vessels and fuel-oil tanks. Cryogenic and hot duty both fit into the -196 to +450 °C span, which is unusually wide for a non-contact sensor. In desalination and utilities, the plastic-faced antenna options help with aggressive chemicals, while in manufacturing the same sensor can be standardised across plants, reducing the number of spare types.
Differences between VEGAPULS 62 and neighbouring models
Against VEGAPULS 61 (3 bar, +80 °C, plastic), the VEGAPULS 62 multiplies the pressure rating more than fifty times and adds metallic wetted parts. Against VEGAPULS 66 (+400 °C, 8 mm deviation, hygienic and bolted flanges from DN 50), it reaches higher temperature, starts at the smaller DN 40 flange and keeps the tighter 2 mm deviation. Against VEGAPULS 65 (16 bar, +150 °C, rod antenna) it is the heavy-duty option. VEGAPULS 64 offers G¾ fittings but only 25 bar.
Installation and parameterisation
Check the nozzle height against the antenna length, avoid placing the sensor above the filling stream, and keep the antenna axis perpendicular to the surface. Wire the loop, close the gland, and parameterise with PLICSCOM or PACTware and DTM; HART communicators and AMS or PDM tools also work. For hazardous areas the sheet lists ATEX and IEC approvals, and ship approvals GL, LRS and ABS, so request the certificate that matches your type label. Where the plant is a classified area, also compare the temperature class with the real process temperature, because a high process temperature may limit what the ambient and electronics can tolerate in that approval.
When the sensor replaces a contacting device such as a float, a displacer or a guided wave probe, expect a very different installation: the radar needs a free beam path rather than a long insertion length, and the nozzle should be short and clean.
Maintenance and ordering of VEGAPULS 62
The sensor is maintenance-free by design, and the encapsulated or horn antenna has no moving or wearing part that would call for a scheduled replacement. On hot or dirty service inspect the antenna for build-up at planned shutdowns, and keep the echo curve stored as a baseline. For quotation give antenna type, material, seal, flange standard, housing and electronics, and mention whether SIL2 or a supplementary radio module or power pack is wanted.
VEGAPULS 62 FAQ summary
- How hot can a VEGAPULS 62 process get? The specification sheet lists a process temperature of -196 to +450 C, with a pressure range of -1 to +160 bar.
- Which metals are available on the VEGAPULS 62? 316L, Alloy C22 (2.4602), Alloy 400 (2.4360) and stainless steel precision casting 1.4848, besides PTFE, PP and PEEK.
- What is the smallest flange for the VEGAPULS 62? Flanges start from DN 40 (1 1/2 in); threads start at G1 1/2 or 1 1/2 NPT.
- Does the 62 stay accurate with steam or gas present? VEGA states the measurement is independent of pressure, temperature, gas and steam, with a 2 mm deviation.
- Is SIL available on the VEGAPULS 62? The sheet states SIL qualification optionally up to SIL2.
Documents and quotation
The manufacturer VEGA VEGAPULS 62 datasheet is available as a PDF download on this page, so your engineers can check ranges, materials and dimensions against the data sheet before ordering. To request a quotation send the part number VEGAPULS 62 together with the quantity, the required process connection, electronics version and any approval requirement through the RFQ form or by email. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; product names and marks belong to their owners.
Datasheets & Documents
- Datasheet VEGA VEGAPULS 62 Radar Level Sensor 160 bar 450 C Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
VEGA is a German maker of level and pressure instruments. Bruno Grieshaber founded the company in 1959 in Triberg in the Black Forest, and it has been based in Schiltach since 1975, still family owned as VEGA Grieshaber KG. VEGA is best known for radar level sensors: it introduced the first two-wire radar level sensor in 1997 and the first 80 GHz radar sensor for bulk solids, the VEGAPULS 69, in 2015.
Seven Star LLC is an independent supplier listing VEGA radar and guided wave radar transmitters, point level switches, pressure transmitters and signal conditioning instruments for buyers in Oman and the GCC. Sensors are matched from the product code on the type label.
VEGA at a glance
| Origin | Founded by Bruno Grieshaber in 1959 in Triberg, Germany |
|---|---|
| Headquarters | Schiltach, Black Forest, Germany (since 1975) |
| Ownership | Family-owned company: VEGA Grieshaber KG |
| Milestones | First two-wire radar level sensor (1997), first 80 GHz radar for bulk solids, VEGAPULS 69 (2015), VEGAPULS 6X single radar platform for liquids and solids |
| Product families | VEGAPULS radar, VEGAFLEX guided wave radar, VEGASWING and VEGAPOINT switches, VEGACAL capacitive probes, VEGABAR and VEGADIF pressure, VEGAMET and VEGADIS signal conditioning |
VEGA sensor and instrument series
| Series | Type | Typical use |
|---|---|---|
| VEGAPULS 6X, VEGAPULS 69, VEGAPULS 64 | Process radar level transmitters (80 GHz) | Storage and process tanks, reactors with agitators, silos and bulk solids |
| VEGAPULS 11, 21, 31, 42 | Compact radar sensors | Water and wastewater, simple storage tanks; VEGAPULS 42 with IO-Link for machine integration |
| VEGAPULS C 21, C 11, C 22, C 23 | Radar sensors with fixed cable, IP68 | Wet wells, pumping stations, open channels and river levels |
| VEGAFLEX 81, 82, 83, 86 | Guided wave radar (TDR) | Level and interface in liquids, bulk solids, hygienic and high-temperature or high-pressure service (VEGAFLEX 86) |
| VEGASWING 61, 63, VEGAPOINT 21 | Vibrating and capacitive point level switches | Overfill protection, dry-run protection and high or low level alarms |
| VEGACAL 62 to VEGACAL 67 | Capacitive rod and cable probes | Point and continuous level in solids and conductive or adhesive liquids |
| VEGABAR 82, 83, 28, 29, 38 | Pressure transmitters, ceramic or metallic cell | Process pressure and hydrostatic level; compact 18/19 and 28/29/38 versions for utilities |
| VEGADIF 85 | Differential pressure transmitter | DP flow, filter monitoring and level in pressurised vessels |
| VEGAMET 841, VEGADIS 176 | Controller and loop display | Level display, pump control and remote indication of 4-20 mA signals |
Where VEGA instruments are used
VEGA radar sensors measure level in crude oil and product tanks, separators, chemical reactors, cement and aggregate silos, grain stores and water reservoirs. Compact cable radars are widely used in wastewater pumping stations and flood monitoring. Because 80 GHz radar focuses a narrow beam, it can measure past internal structures in a tank, and it is not affected by the temperature, pressure or vapour above the product, which suits hot Gulf storage tanks.
Ordering VEGA instruments: what we need
The product code on the type label (for example PS64.XXXXXXX) fixes the measuring range, antenna or probe, process connection, electronics and approvals. Send it with the serial number. For a new measurement add the medium and its dielectric constant if known, tank or silo height and internals, process pressure and temperature, process connection, output (4-20 mA HART, PROFIBUS PA, Modbus or IO-Link), and any hazardous-area or overfill protection approval required.
Facts checked against VEGA company and product information, October 2026.
Browse VEGA products by category: Level Transmitter, Pressure Instrumentation, Controllers and Data Acquisition.
FAQ
Questions about the VEGA VEGAPULS 62 Radar Level Sensor 160 bar 450 C
Answers from our engineering team on installation, compatibility and integration.
01How hot can a VEGAPULS 62 process get?
The specification sheet lists a process temperature of -196 to +450 C, with a pressure range of -1 to +160 bar.
02Which metals are available on the VEGAPULS 62?
316L, Alloy C22 (2.4602), Alloy 400 (2.4360) and stainless steel precision casting 1.4848, besides PTFE, PP and PEEK.
03What is the smallest flange for the VEGAPULS 62?
Flanges start from DN 40 (1 1/2 in); threads start at G1 1/2 or 1 1/2 NPT.
04Does the 62 stay accurate with steam or gas present?
VEGA states the measurement is independent of pressure, temperature, gas and steam, with a 2 mm deviation.
05Is SIL available on the VEGAPULS 62?
The sheet states SIL qualification optionally up to SIL2.


















Reviews