Brand: Phoenix Contact
Phoenix Contact MACX MCR-T-UI-UP Temperature Transducer SIL 2
Description
MACX MCR-T-UI-UP programmable temperature measuring transducer, SIL 2
The MACX MCR-T-UI-UP (item number 2811394) is a freely programmable temperature measuring transducer in a 17.5 mm DIN rail housing. It converts the signal of resistance thermometers, thermocouples, resistance-type sensors, potentiometers or small voltage signals into a linear current or voltage output and adds a limit-value relay with a changeover contact. The wide-range supply of 19.2 to 253 V AC/DC, four-way electrical isolation and functional safety up to SIL 2 make it a universal temperature conditioner for process plants. Seven Star LLC supplies the MACX MCR-T-UI-UP in Oman and the GCC as an independent supplier in Muscat and this page condenses the manufacturer data sheet.
MACX MCR-T-UI-UP type code and versions
| Type | Item no. | Configuration and connection |
|---|---|---|
| MACX MCR-T-UI-UP | 2811394 | Standard configuration, screw connection |
| MACX MCR-T-UI-UP-SP | 2811860 | Standard configuration, push-in connection |
| MACX MCR-T-UI-UP-SP-C | 2811970 | Order configuration (factory-calibrated to customer parameters), push-in connection |
MACX MCR-T-UI-UP technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Phoenix Contact MACX MCR-T-UI-UP, item no. 2811394 |
| Resistance thermometers | Pt, Ni, Cu sensors in 2-, 3- and 4-wire connection |
| Thermocouples | B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG |
| Other inputs | Potentiometer / linear resistance 0 … 50 kΩ; voltage -1000 … +1000 mV |
| Temperature measuring range | -250 °C … 2500 °C depending on sensor type |
| Output | Current 0 … 20 mA (SIL off) or 4 … 20 mA (SIL on), max 22 mA, load ≤ 600 Ω; voltage output up to ±11 V, load ≥ 10 kΩ |
| Relay output | 1 changeover contact, AgSnO2 hard gold-plated, 30 V AC/DC, 0.5 A (AC) / 1 A (DC), mechanical life 1 x 105 cycles |
| Accuracy | Max. transmission error 0.1 % (for example Pt 100, 300 K min. span); temperature coefficient 0.01 %/K |
| Step response (0 … 99 %) | ≤ 1.75 s (SIL on); 1.3 s (SIL off) |
| Supply | 24 … 230 V AC/DC nominal (19.2 … 253 V AC/DC, 50/60 Hz); < 50 mA at 24 V DC; < 1.5 W |
| Isolation | 4-way isolation, test voltage 2.5 kV AC; insulation rated 300 Vrms (IEC/EN 61010-1) between input, output and supply |
| Functional safety | SIL 2 / SC 2 (IEC/EN 61508) on the 4 … 20 mA output; PL d (EN ISO 13849) |
| Hazardous area | ATEX II 3 G Ex ec ic nC IIC T4 Gc; installation in Ex zone 2 permitted |
| Ambient temperature | -20 °C … +65 °C up to 2,000 m; reduced maximum temperature at higher altitude (55 °C above 2,000 m, 50 °C above 3,000 m, 45 °C above 4,000 m) |
| Dimensions | 17.5 x 112.5 x 113.7 mm (W x H x D); PA 6.6-FR housing, UL 94 V0, IP20 |
How the MACX MCR-T-UI-UP is configured
Sensor type, wiring (2, 3 or 4 wire), measuring range, unit, filter, alarm signal and output signal are set by software, using either an FDT/DTM or the clipx ENGINEER DEVICE PARAMETERIZATION program (item 1371665) with the IFS-USB-PROG-ADAPTER (2811271) or the Bluetooth IFS-BT-PROG-ADAPTER (2905872) named in the data sheet. The -C version is configured to the customer order and calibrated ready for operation. A DIP-switch help function is also available through the Signal Conditioner app via the QR code on the housing. The sensor error behaviour is freely programmable, so a broken thermocouple can drive the output to a defined high or low alarm value.
Using the limit relay and the safety options
The integrated relay with a single changeover contact can be configured as a limit switch on the measured temperature, for example to trip a heater or raise an alarm. The data sheet notes a safe limit-value switching function through the optional MACX MCR-I20 current terminal block (2905680) and a cold junction compensation plug MACX MCR-CJC (2924993) for thermocouples. Output 4 to 20 mA is certified up to SIL 2 / SC 2, while temperature sensors and voltage signals may be used with restrictions in such applications, and the PL d rating according to EN ISO 13849 is stated for the device.
System fit and related products
The MACX MCR-T-UI-UP is the DIN-rail alternative to head-mounted temperature transmitters. It makes sense where sensors are wired back to a marshalling cabinet and where one module type should cover Pt 100, Ni, Cu and many thermocouples. A QUINT4-SYS-PS/1AC/24DC/2.5/SC (2904614) supply with TBUS is named in the data sheet for supplying a row of devices. For voltage and current conditioning the MACX MCR-UI-UI-NC and MACX MCR-VDC are the neighbouring Phoenix Contact types.
Selection checklist
- Sensor type, wiring and the full-scale range needed; check that the minimum span meets the accuracy statement.
- Output required: 0/4 … 20 mA or voltage, and the load.
- Need for a limit relay and its rating (30 V, 0.5 A AC or 1 A DC).
- Safety rating: SIL 2 / SC 2 on the 4 … 20 mA output with SIL mode on.
- Supply voltage on site (24 V DC up to 230 V AC) and Zone 2 requirements.
- Screw, push-in, or factory-configured (-C) version.
- Programming adapter and software for commissioning.
Installation and commissioning
Mount the MACX MCR-T-UI-UP on the DIN rail, connect the sensor to the plug-in terminal block (use a 2 mm test socket for test points), and program the module before connecting the loop to the PLC. Verify the measuring chain with a resistance decade box or thermocouple calibrator at several points, check the green PWR LED, the red ERR flashing for sensor errors and the yellow LED for the switching output. Record the parameter file with the loop folder. Since 4-way isolation is provided, no extra isolator is required between sensor and PLC.
Typical applications in Oman and the GCC
The MACX MCR-T-UI-UP is used for process temperature monitoring on heat exchangers, furnaces, compressors, turbine skids, boilers, thermal desalination units and cooling circuits where sensors are Pt 100 or thermocouples and the signal goes to a PLC or DCS. The universal supply allows the same module to be used on 24 V DC or 230 V AC cabinet supplies.
Information to send with an RFQ
- Full type designation or item number, and quantity
- Input signal type and range, output signal required, and any special scaling
- Hazardous-area classification if the module is installed in zone 2
- Supply voltage available and whether DIN rail power bridging is planned
- Required SIL or other approvals
- Delivery location and documents needed
Documents and quotation
The manufacturer data sheet for the MACX MCR-T-UI-UP is attached on this page.
Send item number 2811394, quantity and delivery location to Seven Star LLC and request a quotation.
Other Models in the Pc Macx Analog Range
Seven Star LLC supplies models from the Pc Macx Analog range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Phoenix Contact MACX MCR-UI-UI-NC 3-Way Isolating Amplifier | Isolator & Barrier | View details |
| Phoenix Contact MACX MCR-T-UI-UP Temperature Transducer SIL 2 | Isolator & Barrier | You are viewing this model |
Datasheets & Documents
- Datasheet Phoenix Contact MACX MCR-T-UI-UP Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Phoenix Contact is a German, family-owned manufacturer of electrical connection technology and industrial automation, founded in 1923 in Essen by Hugo Knümann. It began as a sales company, and in 1928 Knümann developed the modular terminal block mounted on a rail, the product the company is still best known for. Phoenix Contact is headquartered in Blomberg, North Rhine-Westphalia.
Seven Star LLC lists Phoenix Contact surge protection, power supplies and safety relays, and sources these components by order number for panel builders and maintenance teams in Oman.
Phoenix Contact company profile
| Founded | 1923, Essen, Germany, by Hugo Knümann, as Phönix Elektro- und Industrie-Bedarfsgesellschaft |
|---|---|
| Headquarters | Blomberg, Germany |
| Ownership | Family-owned (Eisert and Stührenberg families) |
| Key invention | The modular terminal block on a DIN rail, 1928 |
| Product families | CLIPLINE terminal blocks, PCB terminals and connectors, QUINT and TRIO power supplies, relay modules, surge protection, signal conditioners, Ethernet switches and PLCnext controllers |
Milestones
- 1923: Hugo Knümann founds the company in Essen.
- 1928: The first modular terminal block is developed.
- Later: Headquarters move to Blomberg, Ostwestfalen-Lippe.
Phoenix Contact parts listed on this page
The TTC-6-2X1-24DC-UT (order number 2906799) is a surge protection device with screw connection for two 24 V DC signal wires that share a common reference potential. The QUINT-PS/1AC/24DC/10 is a single-phase DIN rail power supply delivering 24 V DC at 10 A. The PSR-SCP-24DC/ESP4/2X1/1X2 (order number 2981020) is a single-channel PSR safety relay for emergency stop and safety door monitoring, with two enabling current paths and plug-in screw terminals.
Phoenix Contact products we list
Ordering Phoenix Contact components: what we need
Phoenix Contact items are ordered by a seven-digit order number together with the type designation, both printed on the side of the module. Send both, plus the quantity. If the number is unreadable, send the type text and a photo. For power supplies, state input voltage, output current and whether the unit runs in parallel or with a redundancy module. For buyers in the GCC replacing an older unit, we check the manufacturer's documentation for the listed successor type.
Facts checked against Phoenix Contact's own company history (phoenixcontact.com), October 2026.
Browse Phoenix Contact products by category: Isolator & Barrier, Power Modules, Automation Accessories.
FAQ
Questions about the Phoenix Contact MACX MCR-T-UI-UP Temperature
Answers from our engineering team on installation, compatibility and integration.
01Which sensors can the MACX MCR-T-UI-UP read?
Pt, Ni and Cu resistance thermometers in 2-, 3- or 4-wire connection, a wide list of thermocouple types (B, E, J, K, N, R, S, T, L, U and more), potentiometers up to 50 kilohm and voltages of plus or minus 1000 mV.
02How accurate is it?
The maximum transmission error is 0.1 percent (stated for Pt 100 with a minimum span of 300 K), and the temperature coefficient is 0.01 percent per kelvin.
03What is the supply range?
The module accepts 19.2 to 253 V AC/DC at 50/60 Hz, nominal 24 to 230 V AC/DC, with consumption below 1.5 W.
04Is it a safety device?
It is certified for safety-related applications up to SIL 2 / SC 2 on the 4 to 20 mA output with IEC/EN 61508, and PL d according to EN ISO 13849.
05How is it configured?
Using FDT/DTM or the clipx ENGINEER DEVICE PARAMETERIZATION software with a USB or Bluetooth programming adapter; the -C versions are factory configured to order.