Brand:

Metrohm 6.0262.100 Ecotrode Plus Combined pH Electrode

Description

Overview

Not every laboratory needs the most specialised sensor; many simply need one dependable electrode for everyday acid-base titration. The Metrohm 6.0262.100 Ecotrode Plus is Metrohm’s value-oriented combined pH glass electrode for exactly this: aqueous acid and base titrations in routine use. It has a glass shaft, a fixed ground-joint diaphragm that resists contamination and a reference system built for long-term stability. It is supplied without a temperature sensor and without a cable, so the buyer chooses the cable that matches the instrument. Seven Star LLC is an independent supplier serving Oman and the GCC.

Metrohm markets it under the line “high durability in routine use at a fair price”, and it carries the plug-in head G.

Technical data for Metrohm 6.0262.100

Characteristic Ecotrode Plus value
Membrane glass Type E, hemispherical indicator
Membrane resistance 150 to 400 megaohm
pH range 0 to 13
Temperature range 0 to 80 degrees C, long and short term
Zero point and slope Plus or minus 15 mV; slope above 0.97
Diaphragm Fixed ground-joint
Reference electrolyte 3 mol/L KCl, flow 5 to 30 microlitres per hour
Reference system LL system with long-term stability
Shaft Glass, 12 mm diameter, installation length 125 mm
Minimum immersion depth 20 mm
Plug-in head Metrohm plug-in head G
Delivery Without temperature sensor and without cable

What the pH 0 to 13 range tells you

The type E glass is specified up to pH 13, one unit below the 14 of the Unitrode and Solitrode. For acid-base titrations of typical aqueous samples this is more than enough,; type E glass is intended for aqueous acid-base work and not for strongly alkaline media. If you work in more strongly alkaline solutions, step up to a type U or type T electrode. The temperature limit of 80 degrees C applies to both long-term and short-term use, which is a simpler rule than the two-tier limits of the Unitrode.

How 6.0262.100 differs from the Unitrode and Solitrode

The 6.0262.100 and the Solitrode 6.0220.100 both use a hemispherical sensing surface and need 20 mm and 15 mm immersion respectively, but the Ecotrode Plus has a glass shaft and a fixed ground-joint diaphragm whereas the Solitrode has an unbreakable polypropylene shaft with a ceramic diaphragm. Membrane resistance is 150 to 400 megaohm here, compared with 200 to 500 megaohm for the Solitrode and 150 to 500 megaohm for the Unitrode. None of the three includes the Pt1000 in this article number, although the Unitrode and a Solitrode variant do offer one.

Intelligent and digital relatives

The same Ecotrode Plus design is offered as the iEcotrode Plus with a memory chip for Metrohm’s iConnect system, and in the dEcotrode plus form with a digital interface. The catalog recommends the Ecotrode Plus family for aqueous titrants such as hydrochloric acid, sodium hydroxide and sulfuric acid. If your laboratory wants automatic recognition of the electrode and stored calibration data, ask us for the iTrode version.

Applications in Oman and the GCC

Water laboratories at power plants, desalination plants and municipalities use the Ecotrode Plus for alkalinity, acidity and total hardness titrations, while food and beverage laboratories run acidity of juices and dairy. Teaching laboratories prefer it because of its price, and quality control laboratories choose it as a spare that can be replaced often without large budget effects.

Planning spares and routine use

A routine laboratory that runs titrations every day should keep at least one spare electrode on the shelf, and the Ecotrode Plus is priced for exactly this role. Rotate electrodes so that a spare is always conditioned in storage solution and ready for use. Record the date of first use, the slope and the zero point at each calibration; when the slope drops toward the 0.97 limit or the zero point drifts outside plus or minus 15 mV, replace the electrode rather than chasing erratic results. Because the diaphragm is fixed and needs no sleeve handling, the maintenance workload is small, but the electrolyte level must still be watched and topped up through the filler opening, and the electrolyte should be renewed periodically.

Typical titrations with the Ecotrode Plus

Alkalinity of cooling and boiler water is titrated with hydrochloric acid to a preset pH, acidity with sodium hydroxide, and total acid content of beverages with sodium hydroxide to a fixed endpoint. In every case the titrant is aqueous and the solvent is water, which is the situation the electrode was designed for. For non-aqueous solvents such as alcohols or oils choose the Solvotrode instead, for solutions with solids the Unitrode, and for very difficult matrices a double-junction electrode. Selecting the right electrode for the matrix prevents most measurement problems before they start, which is why we always ask about the sample when we quote.

Preparing the electrode

Check the electrode immediately after unpacking by calibrating with buffers or by running the electrode test on a Metrohm meter or titrator, selecting the standard type for electrodes filled with 3 mol/L KCl. Open the filler opening and fill electrolyte up to the opening, and keep it open during measurement so that the electrolyte can flow.

Storage and cleaning

Store in the Metrohm storage solution 6.2323.000 so that the response time stays unchanged and the electrode can be used at once. Never store dry, never clean in an ultrasonic bath, and keep the tip clean without touching it. For protein-containing samples use pepsin in hydrochloric acid; for low-ion solutions consider the Aquatrode Plus instead.

Ordering Metrohm 6.0262.100

Please quote Metrohm 6.0262.100, and add the cable article that matches your meter or titrator, since the electrode is delivered without a cable. We can add buffers, storage solution and electrolyte. Seven Star LLC serves Oman and the GCC.

Related items you may also need: Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 888 Titrando Potentiometric Titrator | Metrohm 905 Titrando Potentiometric Titrator | All Metrohm products.

Documents and quotation

The Metrosensor electrode catalog that lists this electrode is attached as the datasheet. Please send your RFQ with the part number Metrohm 6.0262.100, quantity and delivery location, and we will respond with availability and lead time.

Other Models in the PH Electrodes Range

Seven Star LLC supplies models from the PH Electrodes range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Metrohm 6.0229.010 Solvotrode easyClean Non-Aqueous pH ElectrodeLiquid Analysis SensorsView details
Metrohm 6.0258.600 Unitrode with Pt1000 pH ElectrodeLiquid Analysis SensorsView details
Metrohm 6.0262.100 Ecotrode Plus Combined pH ElectrodeLiquid Analysis SensorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Metrohm 6.0262.100 Ecotrode Plus Combined pH Electrode Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.

Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.

Metrohm company profile

Founded 1943, Herisau, Switzerland
Founder Bertold Suhner
Headquarters Herisau, Switzerland
Ownership Metrohm Foundation
Product families Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes

Metrohm instruments listed here

The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.

Metrohm products we list

Family Examples
Liquid Analytical Systems 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr…

Ordering Metrohm equipment: what we need

Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.

Facts checked against Metrohm's published company history, October 2026.

FAQ

Questions about the Metrohm 6.0262.100 Ecotrode Plus Combined pH

Answers from our engineering team on installation, compatibility and integration.

01Does the Metrohm 6.0262.100 Ecotrode Plus include a cable?
No. It is supplied without cable and without temperature sensor, so a suitable cable must be ordered separately.
02What pH range does the 6.0262.100 cover?
The type E glass is specified for pH 0 to 13 and temperatures from 0 to 80 degrees C.
03Which diaphragm and electrolyte does the 6.0262.100 use?
It has a fixed ground-joint diaphragm insensitive to contamination and is filled with 3 mol/L potassium chloride.
04How deep must the 6.0262.100 be immersed?
The minimum immersion depth is 20 mm, with an installation length of 125 mm and a shaft diameter of 12 mm.
05Which plug-in head does the 6.0262.100 have?
It carries Metrohm plug-in head G; intelligent and digital versions of the Ecotrode Plus exist for iConnect systems.