Brand:

Circutor computer C6 Wi-Fi Power Factor Controller

Description

A simple 6-step regulator for balanced installations, with Wi-Fi set-up

The Circutor computer C6 Wi-Fi (code R14831) is a six-step power factor regulator for contactor-switched capacitor banks. Circutor designs the Computer C Wi-Fi series for simple and effective regulation, with a high-contrast display that can show up to 27 electrical parameters and up to 12 fully configurable alarms.

It is aimed at balanced installations where ease of programming, robustness, precision and control of compensation matter more than three-CT measurement. A simple, intuitive programming system helps with installation and maintenance, plug-and-play setup and programming through the MyConfig app, and compatibility with the Anti Reactive Surveillance System (VAR).

computer C6 Wi-Fi functions

  • 6 contactor steps plus one alarm relay
  • High-contrast display with up to 27 electrical parameters
  • Up to 12 configurable alarms to support preventive maintenance
  • Programming via the MyConfig app; compatible with the Anti Reactive Surveillance System – VAR
  • Single CT input …/5 A with 0.05 to 5 A measuring range; connect preferably to phase L1
  • Wi-Fi interface and 3-key keyboard
  • Compact 144 x 144 x 54.85 mm panel format; double-insulated, class II

computer C6 Wi-Fi technical specifications

Identification and supply

Parameter Specification
Nominal supply voltage 400 V ac (+/-10 pct); 50 … 60 Hz
Consumption / installation category 13 VA / CAT III 300 V
Measurement range (V) 400
Reference R14831. / computer C6 Wi-Fi, power factor regulator
Number of steps / switching unit 6 / contactor
Alarm relay Yes

Measurement

Parameter Specification
Precision class Phase angle 2 pct +/-1 digit; phase current 1 pct; phase voltage 1 pct
Current input …/5 A; phase current range 0.05 … 5 A; permanent overload +20 pct; connect preferably to phase L1

Outputs and interface

Parameter Specification
Display / keyboard 3-digit display resolution / 3 keys
Relay outputs 6 + 1 (alarm); 1 A ac; open contact 250 V ac; 250 W maximum switching capacity; 1 x 10^5 electrical cycles; 1 x 10^7 mechanical cycles

Mechanical, environmental and standards

Parameter Specification
Humidity (no condensation) 5 … 95 pct
Highest altitude / pollution degree 2000 m / pollution degree 2
Insulation Double-insulated, electric shock protection class II (IEC 61010-1)
Norms IEC 61010, IEC 61000-2-30, IEC 61000-6-4, IEC 61000-6-2
Outline W x H x D / weight 144 x 144 x 54.85 mm / 0.43 kg
Enclosure / fastening Plastic V0 self-extinguishing / panel
Ingress rating IP 30; front panel IP 40; IK 08
Working / storage temperature -20 … +60 C / -20 … +70 C

C6 or C12, and the version suffix

The Computer C Wi-Fi series has four listed codes: C6 Wi-Fi (R14831. and R148310020000) and C12 Wi-Fi (R14842. and R148420020000), all contactor switching with a …/5 A input. The 0020000 versions are listed as separate codes; we quote R14831 here. Remember it is a 400 V nominal single-CT regulator, so it is for balanced loads; for unbalanced loads choose the SMART III family with three CTs.

Installation and operation notes

Panel mounting uses a 144 x 144 mm cut-out and the unit is only 54.85 mm deep. Connect the CT to phase L1, as the datasheet prefers. The 0.05 to 5 A measuring range means the CT secondary and ratio must give enough signal at light load. Programming is by keyboard or by the MyConfig app; the front panel is IP40 and the working range -20 to +60 C, which is wider than the SMART III family.

Where the C6 Wi-Fi is used

Simple automatic capacitor banks for workshops, small plants, commercial buildings and pump houses where loads are balanced and fast response is not required. The 60 C upper limit is a printed figure; mount the regulator away from the capacitor contactors and heat sources in a ventilated cubicle.

Selection and installation notes

Before ordering a power factor regulator, collect the data the sizing depends on: the supply voltage and frequency, the current transformer ratio and where the transformer is fitted, the number and size of the capacitor steps, the contactor or static switch type and whether harmonics are present on the network. Fit the current transformer upstream of both the load and the capacitor bank so that the regulator sees the net current, connect it with the polarity shown in the manual and let the regulator run its automatic set-up before the first start. Check the alarm and relay settings and write the final values on the commissioning record so that later service work starts from a known state.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Related Circutor items

For larger or unbalanced loads see the computer SMART III 14 (R13864.). Hybrid compensators (OPTIM SVGm), active filters (AFQs) and detuning reactors (LRZ and LRBZ) are also listed separately.

Frequently asked questions

How many steps does the C6 Wi-Fi control?

Six contactor steps, plus an alarm relay.

What supply voltage does it need?

400 V ac (+/-10 percent), 50 to 60 Hz.

How is it programmed?

From the front keyboard or through the MyConfig app.

Is it suitable for unbalanced loads?

The datasheet recommends it for balanced installations; it has a single …/5 A current input.

Is Seven Star LLC a distributor of Circutor?

No. Seven Star LLC is an independent supplier in Muscat, Oman, sourcing genuine Circutor products for GCC customers on request.

Documents and quotation

Download the computer C6 Wi-Fi datasheet (generated 21/10/2026) from this page and read it alongside the manual when you verify the model code. Our quotation form takes the exact model, options and quantity, and Seven Star LLC, an independent Muscat supplier serving the GCC, replies with availability for Circutor equipment. No prices are listed; confirm all ratings, options and approvals against current manufacturer documents before ordering. Related pages: Electrical & Power, Circutor.

Datasheets & Documents
  • PDF Datasheet Circutor computer C6 Wi-Fi datasheet (generated 21/10/2026) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Circutor is a Spanish manufacturer of equipment for power factor correction, harmonic filtering and electrical measurement, founded in 1973 and based in Viladecavalls near Barcelona.

Seven Star LLC is an independent supplier in Muscat. We list Circutor power quality equipment, each with the manufacturer datasheet, for industrial plants, commercial buildings and utilities in Oman and the GCC.

Circutor product series

Power factor controllers include the computer SMART III 14, the SMART III Fast 6 for static (thyristor) capacitor banks, the SMART III F6-12Vdc and the computer C6 with Wi-Fi. The OPTIM SVGm-200-440 and SVGm-600-440 are hybrid var compensators that combine capacitor steps with an active generator for fast, stepless correction.

The AFQs-3WF-030M is a 30 A active harmonic filter, the LRZ 04-033 and LRBZ 04-080 are line reactors for power converters, and the CIRWATT B410T is an energy meter for tariff and sub-metering points.

Where Circutor equipment is used

Industrial plants, commercial buildings and utilities with large motor, drive or air-conditioning loads, to hold power factor, limit harmonic distortion, protect converters and measure energy.

Ordering Circutor equipment: what we need

Send the product code, system voltage and frequency, the current transformer ratio, the number of capacitor steps or the load in kvar or amps, and the quantity.

Frequently Asked Questions

How many steps does the C6 Wi-Fi control?
Six contactor steps, plus an alarm relay.
What supply voltage does it need?
400 V ac (+/-10 percent), 50 to 60 Hz.
How is it programmed?
From the front keyboard or through the MyConfig app.
Is it suitable for unbalanced loads?
The datasheet recommends it for balanced installations; it has a single .../5 A current input.
Is Seven Star LLC a distributor of Circutor?
No. Seven Star LLC is an independent supplier in Muscat, Oman, sourcing genuine Circutor products for GCC customers on request.