- Automation & ControlView all 1,865 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: KOBOLD
KOBOLD MIM All-Metal Magnetic Inductive Flow Meter, IO-Link
Description
All-metal electromagnetic flow meter for small and medium lines
The KOBOLD MIM is an all-metal magnetic inductive flow meter for measuring and monitoring small and medium flows of conductive liquids. It works on Faraday induction: the conductive liquid moving through a magnetic field induces a voltage proportional to flow velocity, picked up by two electrodes. The measurement does not depend on density, viscosity or temperature of the liquid, and it is bidirectional.
The housing, connection fitting and electrodes are stainless steel 1.4404 with PEEK insulation. The universal U-PACE electronics add a colour TFT display, four optical touch keys usable with gloves, two freely configurable outputs, dosing, a resettable and a grand totaliser, PT1000 temperature measurement, and IO-Link. The MIM-13 wetted parts conform to DVGW 270 and WRAS drinking water guidelines, except range code 35.
Technical specifications
| Parameter | Specification |
|---|---|
| Measuring principle | Electromagnetic (Faraday), bidirectional |
| Medium | Conductive liquids, minimum conductivity 20 µS/cm (35 µS/cm for ranges 01H and 01G) |
| Accuracy / repeatability | Below ±(0.8 % of reading + 0.5 % of full scale) / ±0.2 % of full scale |
| Maximum pressure | 16 bar |
| Media temperature | Compact -20 to +70 °C (short-term +85 °C); remote with PVC cable -20 to +85 °C; remote with ETFE cable -20 to +140 °C (MIM-13 -40 to +140 °C) |
| Temperature measurement | PT1000, ±2 °C, flow above 0.2 m/s |
| Response time | Below 100 ms (alarm, pulse, frequency); below 1 s (analogue) |
| Wetted materials | Fitting and electrodes stainless steel 1.4404; PEEK insulation; FKM seals (EPDM option, standard on MIM-13) |
| Supply | 19 to 30 VDC, up to 200 mA; M12 x 1 plug, 4-pin |
| Outputs | Two configurable: 4 to 20 mA, 0 to 20 mA, 0 to 10 V, 2 to 10 V, switching, pulse, frequency; control input and dosing; IO-Link V1.1 |
| Protection | IP67; shock 20 g, vibration 5 g |
| Piping | Inlet 3 x DN, outlet 2 x DN; any mounting direction |
| Conformity | Regulation (EC) No 1935/2004 (food contact); CSA ordinary locations and IECEE CB scheme for U-PACE electronics |
Connections and ranges
| Connection | Inside diameter | Ranges |
|---|---|---|
| G ¼ | 2.4 x 3 mm | 0.01 to 1 l/min |
| G ½ | 5 mm | 0.03 to 3; 0.04 to 10 l/min |
| G ¾ | 10 mm | 0.1 to 25; 0.2 to 50 l/min |
| G 1 | 15 mm | 0.2 to 50; 0.4 to 100 l/min |
| G 2 | per drawing | 1.5 to 350; 3 to 650 l/min |
NPT female versions from ½” to 2″ are offered with GPM and GPH ranges. Compact (C3T) and remote (P02 with PVC cable, E02 with ETFE cable, lengths 2 to 20 m) designs are available; wall mounting brackets are included with the remote version.
Ordering and selection
The order example is MIM-12 15H G5 C3T 0: MIM-12 (housing and electrodes stainless steel with FKM seals) or MIM-13 (EPDM seals), range code, connection, electronics and special version. The l/min package carries l/min, °C and bar on the nameplate; the GPM package uses GPM, °F and PSI. A calibration report with five measuring points is an option.
The MIM is not for non-conductive liquids such as oils, fuels or demineralised water below the conductivity limit. Confirm before ordering: conductivity, temperature against the cable version, pressure, drinking water compliance if needed, and the output or IO-Link configuration.
Related KOBOLD products: KOBOLD BGN All-Metal Variable Area Flow Meter, up to 350 °C, KOBOLD TMU Coriolis Mass Flow Meter, 60 to 80 000 kg/h, KOBOLD KEC Thermal Mass Flow Meter for Gases, Modbus, KOBOLD DRB Turbine Wheel Flow Meter for Liquids, to 750 l/min, KOBOLD DOG-4 / DOG-6 Oscillation Flow Meter for Gases and KOBOLD DON-H High-Pressure Oval Gear Flow Meter, 400 bar.
Documents and quotation
The KOBOLD MIM datasheet (edition 2/04-2026) is attached to this page. Browse our Flowmeters category for related instruments, or compare with the GF Signet 3-2551 insertion magmeter.
For a quotation, send the liquid and its conductivity, flow range, connection, temperature and pressure, seal material, compact or remote design and output requirements.
Datasheets & Documents
- Datasheet KOBOLD MIM magnetic inductive flow meter datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KOBOLD Messring is a German manufacturer of instruments for flow, pressure, level and temperature, founded in 1980 by engineer Klaus J. Kobold in Hofheim am Taunus. Patented measuring principles helped the company establish itself quickly, and independent KOBOLD companies were later set up in many countries, including KOBOLD Instruments Inc. in the United States in 1989.
Seven Star LLC is an independent supplier in Muscat. We list selected KOBOLD flow and level instruments for oil and gas, water, power and process plants in Oman and the GCC.
KOBOLD company profile
| Founded | 1980, Hofheim am Taunus, Germany, by Dipl.-Ing. Klaus J. Kobold |
|---|---|
| Headquarters | Nordring, Hofheim am Taunus, Germany |
| Ownership | Privately owned |
| Measured variables | Flow, pressure, level and temperature |
| Product families | Variable area flowmeters, paddle and vane flow switches, magnetic-inductive and oval gear meters, pressure switches and transmitters, level switches and sensors, temperature instruments |
Milestones
- 1980: Klaus J. Kobold founds KOBOLD Messring.
- 1989: KOBOLD Instruments Inc. is established in the United States.
KOBOLD product series
Flow instruments include the TMU Coriolis mass flow meter from 60 to 80,000 kg/h, the KEC thermal mass flow meter for gases, the MIM all-metal magnetic inductive meter with IO-Link, the DRB turbine wheel meter, the DON-H high-pressure oval gear meter for 400 bar, the DOG-4 and DOG-6 oscillation meters for gases, the BGN all-metal variable area meter for up to 350 °C and the KAL calorimetric flow monitor for water.
Level instruments include the NGM guided wave radar transmitter, the NRE 80 GHz non-contact radar, the NMB magnetostrictive transmitter, the NWS tuning fork switch and the NBK-03 bypass magnetic level indicator for pressures up to PN 320.
Where KOBOLD instruments are used
Cooling water and lube oil monitoring on machines, chemical dosing and fuel metering, compressed air and gas consumption, tank and vessel level in process plants, and boiler and condensate systems. Many models carry ATEX or IECEx approvals and offer HART, Modbus or IO-Link.
KOBOLD products we list
Ordering KOBOLD instruments: what we need
Send the model code, the medium, measuring range, pressure and temperature, process connection and materials, output signal and any hazardous-area approval needed, and we will prepare a quotation from the KOBOLD datasheet.
Facts checked against KOBOLD's own company pages (kobold.com) and distributor information, October 2026.
Browse KOBOLD products by category: Flowmeters, Level Instrumentation.
FAQ
Questions about the KOBOLD MIM All-Metal Magnetic Inductive Flow Meter,
Answers from our engineering team on installation, compatibility and integration.
01What does the KOBOLD MIM measure?
Flow of conductive liquids, with flow, temperature, dosing and totaliser functions in one device.
02What is the minimum conductivity?
20 µS/cm, or 35 µS/cm for the smallest ranges 01H and 01G.
03What accuracy does the MIM reach?
Below ±(0.8 % of reading + 0.5 % of full scale) at reference conditions.
04Does the MIM support IO-Link?
Yes. It supports IO-Link V1.1, and the two outputs can be configured as analogue, switching, pulse or frequency.
05Is the MIM suitable for drinking water?
The MIM-13 wetted parts conform to DVGW 270 and WRAS guidelines, except measuring range code 35.