- Automation & ControlView all 1,920 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Motor Soft Starters
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Helukabel
Helukabel HELUCOM AT-V(ZN)HH(ZN)B2Y OM2 Fibre Optic Cable
Description
The Helukabel HELUCOM AT-V(ZN)HH(ZN)B2Y is a rugged outdoor fibre optic breakout cable with four multimode G50/125 (OM2) fibres. Each fibre sits in its own composite buffered core, the cable has a GRP support element, aramid strain-relief yarns, a ULSZH inner sheath, glass-yarn armouring and a black UV-resistant polyethylene outer sheath. It is longitudinally water-tight and built for fixed outdoor installation in demanding industrial environments.
Technical specifications
| Parameter | Specification |
|---|---|
| Type | AT-V(ZN)HH(ZN)B2Y, fibre optic breakout cable, outdoor |
| Fibres | 4 x multimode G50/125, fibre category OM2 |
| Core type | Composite buffered; GRP support element |
| Strain relief | Aramid yarns |
| Armouring | Glass yarns |
| Inner sheath | ULSZH |
| Outer sheath | PE, black |
| Outer diameter | Approx. 13.5 mm |
| Max. tensile force | 1200 N |
| Min. static bending radius | 340 mm |
| Max. transverse pressure | 300 N/cm |
| Temperature range | Laying -5 °C to +50 °C; operating -20 °C to +60 °C |
| Weight and caloric load | Approx. 140 kg/km; approx. 2.95 MJ/m |
| Other data | Longitudinally water-tight acc. to IEC 60794-1-2-F5; UV-resistant; oil-resistant |
Breakout construction and where it fits
In a breakout cable every fibre is its own tight-buffered or composite-buffered core with aramid reinforcement, so each leg can be terminated directly with a connector without a fan-out kit. Helukabel notes that the tight-buffer structure enables the cable to be pre-assembled on site with ease, and that the HELUCOM range is set apart by its rugged, rodent-protected design for demanding environmental conditions with fixed installation.
Choosing the fibre and link design
A 50/125 OM2 link suits short and medium distances inside a site, such as between a control building and a field junction box or between switch cabinets. For longer plant backbones, single-mode fibre has far greater reach, so choose the fibre type from the link budget of the switches and transceivers. Check the optical budget, connector type (LC, SC or ST) and the pulling tension before ordering, and do not exceed the 1200 N tensile limit or the 340 mm static bending radius.
Other HELUCOM fibre cables listed by Helukabel for comparison (values from each data sheet):
| Part no. | Designation | Fibres | Outer sheath | Outer diameter mm | Max. tensile force N |
|---|---|---|---|---|---|
| 801352 (this cable) | AT-V(ZN)HH(ZN)B2Y | 4 x OM2 G50/125 | PE, black | 13.5 | 1200 |
| 805445 | AT-V(ZN)H(ZN)BH | 2 x OM2 G50/125 | FRNC, black | 8.0 | 1000 |
| 805687 | AT-V(ZN)H(ZN)BH | 4 x single-mode E9/125 (ITU-T G.652) | FRNC, black | 9.0 | 1000 |
| 801196 | AT-VQH(ZN)B2Y | 2 x HCS 200/230 | PE, black | 11.0 | 1500 |
| 800126 | AT-VYY | 2 x OM1 G62.5/125, tight buffer | PVC, black | 6.8 x 10.2 | 400 |
Related Helukabel products: Helukabel (N)HXH-FE 180/E 90 Fire-Resistant Power Cable, Helukabel H07RN-F Heavy Duty Rubber Cable, Helukabel JE-H(St)H Bd FE 180/E 30-E 90 Fire Alarm Cable, Helukabel HELUKAT PROFInet A Cat.5e Industrial Ethernet Cable, Helukabel TOPFLEX-EMV-3-PLUS Screened VFD Motor Cable and Helukabel N2XH-J Halogen-Free 0.6/1 kV Power Cable.
Documents and quotation
The Helukabel data sheet is attached. Seven Star LLC supplies Helukabel cables in Oman against the part number 801352. Confirm fibre count, fibre category, drum length and connector requirements. Matching optical transceivers are in the industrial communications category, for example the Winsonic multimode SFP transceiver.
Datasheets & Documents
- Datasheet HELUKABEL HELUCOM AT-V(ZN)HH(ZN)B2Y data sheet (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HELUKABEL is the German manufacturer and supplier of cables, wires and cable accessories, with a range that covers control, power, data, fire-resistant and drag-chain cables. Helmut Luksch and his wife founded the company in 1978 in Hemmingen, near Stuttgart. The name combines the first letters of his first and last name (HElmut LUksch) with the word for cable (Kabel). It has made its own cables since 1988.
Seven Star LLC is an independent supplier in Muscat. We list HELUKABEL control, power, VFD, data and fire-resistant cables and supply them to contractors, panel builders and plants in Oman and the GCC by type, cross-section and length.
HELUKABEL at a glance
| Established | 1978, Hemmingen near Stuttgart, Germany, by Helmut Luksch |
|---|---|
| Manufacturing | Own production since 1988, starting at the Windsbach plant |
| Product families | Control and power cables, screened VFD motor cables, data and bus cables, fire-resistant and halogen-free cables, flexible rubber and welding cables, cable glands and accessories |
| Ownership | Family-owned, managed by the Luksch family |
HELUKABEL cables we list
| Cable | Type | Typical use |
|---|---|---|
| JZ-500, JZ-500 HMH, JZ-600-Y-CY | Control cables | Wiring of machines and panels; HMH is halogen-free, Y-CY is screened |
| NYY-J, N2XH-J | 0.6/1 kV power cables | Power distribution; N2XH-J for buildings where halogen-free cable is required |
| TOPFLEX-EMV-3-PLUS, TOPFLEX-EMV-UV, TOPFLEX 611-C-PUR | Screened motor cables | Connecting motors to variable speed drives and servo drives with low interference |
| (N)HXH-FE 180/E 90, JE-H(St)H Bd FE 180 | Fire-resistant cables | Safety circuits, fire alarm systems and emergency power that must keep working in a fire |
| PAAR-TRONIC-CY, SUPER-PAAR-TRONIC-C-PUR, OZ-BL-CY | Signal and instrument cables | Measurement signals, drag chains, and blue-sheathed intrinsically safe circuits |
| H07RN-F, H01N2-D | Rubber cables | Mobile equipment, temporary power and arc welding |
The code on a European cable describes its build. In NYY-J, N means a standard type, Y a PVC insulation and sheath, and J a green-yellow earth core. In N2XH, 2X is XLPE insulation and H a halogen-free sheath. A C or CY in the name marks a copper braid screen. FE 180 and E 90 are the fire tests: insulation integrity for 180 minutes and circuit function for 90 minutes as an installed system.
Where HELUKABEL cables are used
In Oman and the GCC, HELUKABEL cables are used in oil and gas and process plants, motor control centres and VFD installations, building fire alarm and life safety systems, machinery and cranes, and water and power infrastructure.
Ordering HELUKABEL cables: what we need
Send the cable type, the number of cores and cross-section (for example 4G2.5 or 3x150+70), the length, and whether you need a specific standard or certificate. For fire-resistant cables, add the required test (FE 180, E 30 or E 90).
Facts checked against HELUKABEL company history, October 2026.
Browse Helukabel products by category: Industrial Cables, Welding Accessories & Safety.
FAQ
Questions about the Helukabel HELUCOM AT-V(ZN)HH(ZN)B2Y OM2 Fibre Optic
Answers from our engineering team on installation, compatibility and integration.
01How many fibres and what type?
Four multimode G50/125 fibres, category OM2.
02Is it suitable for outdoor installation?
Yes. It has a black UV-resistant PE outer sheath, is longitudinally water-tight to IEC 60794-1-2-F5 and is specified for outdoor use in fixed installation.
03What is the maximum tensile force?
1200 N.
04What is the operating temperature range?
-20 °C to +60 °C in operation and -5 °C to +50 °C during laying.
05What is a breakout cable?
A cable in which each fibre has its own reinforced core, so each fibre can be terminated directly with a connector.