The Simtronics GD10-P00-17DG-0XH-00 Infrared Gas Detector is a GD10P Series point detector from Teledyne Simtronics, designed for combustible gas detection in industrial plants. The GD10P Series is an infrared gas detector family, and this configuration is set up for CH4 methane detection over the 0-100% LEL range, with ATEX certification for use in hazardous areas and HART communication for integration with plant control systems. For oil, gas and petrochemical facilities in Oman and the GCC, the Simtronics GD10-P00-17DG-0XH-00 is a genuine replacement detector for installed Simtronics gas detection systems.

Engineering Design

The GD10P detector uses infrared measurement technology to monitor the presence of combustible gas in the atmosphere. The infrared source and detector arrangement measures the absorption of infrared energy by the target gas, and because the measurement principle is physical rather than catalytic, the sensor is not consumed by the gas it detects. This configuration is specified for CH4 methane monitoring over the full 0-100% LEL range, with the detector output available through the HART protocol, which allows the device to be interrogated, calibrated and diagnosed digitally over the same two-wire loop used for the measurement signal.

Compatibility & Integration

The detector is part of the Simtronics GD10P Series, so it integrates with existing Simtronics gas detection systems and their associated monitoring infrastructure. The HART output allows the detector to be connected to HART-capable control systems, marshalling panels and handheld communicators, which simplifies commissioning and routine maintenance in plants that already use HART instruments.

With ATEX certification, the Simtronics GD10-P00-17DG-0XH-00 is suited to hazardous-area installations where combustible gas may be present, and the 0-100% LEL range gives the control room a direct reading of how close the atmosphere is to the lower explosive limit. Plants typically mount the detector in the gas release risk areas and connect the output to the fire and gas system or the process control system.

Key Features

  • GD10P Series infrared gas detector from Teledyne Simtronics
  • CH4 methane detection over 0-100% LEL
  • ATEX certified for use in hazardous areas
  • HART communication for digital integration with plant systems
  • Infrared measurement principle with no consumable sensing element
  • Full configuration: Simtronics GD10-P00-17DG-0XH-00

Industrial Applications

  • Combustible gas monitoring in oil, gas and petrochemical facilities
  • Gas compressor stations, processing units and storage areas
  • Hazardous-area installations requiring ATEX-certified detectors
  • Plants across Oman and the GCC operating Simtronics gas detection systems

Technical Specifications

Parameter Specification
Series GD10P Series – Infrared Gas Detector
Manufacturer Teledyne Simtronics
Configuration Simtronics GD10-P00-17DG-0XH-00
Target gas CH4 methane
Measurement range 0-100% LEL
Certification ATEX
Communication HART
Commodity Gas detection equipment

Why Seven Star LLC

Seven Star LLC supplies gas detection equipment and spares to industrial customers across Oman and the wider GCC region. Every GD10-P00-17DG-0XH-00 we supply is checked against the configuration code before dispatch, and our team confirms the detector matches your installed Simtronics system and hazardous-area classification before you order.

Reading the GD10P Configuration Code

Simtronics GD10P detectors are identified by a full configuration code, and every position in the code matters. It defines items such as the gas calibration, the measuring range, the output and communication option, and the certification. For a like-for-like replacement, copy the complete code from the label of the installed detector rather than ordering by series name alone. Also check:

  • That the target gas and range on the label, CH4 methane at 0-100% LEL for this unit, match the fire and gas cause and effect documentation.
  • The certification marking and cable entry arrangement required at the installation point.
  • The accessories used on site, such as the weather protection, calibration adaptor and mounting bracket.

Installation and Commissioning

Methane is lighter than air, so point detectors for methane are normally placed above potential leak sources such as compressor seals, flanges and valve stations. Final positions should follow the site gas detection layout, taking air movement and ventilation into account. After wiring and power-up, allow the detector to warm up and stabilise. Then confirm the zero reading in clean air and verify the response with certified methane test gas applied through the correct calibration accessory. Use the HART connection to check the device configuration and tag. Finish by confirming the analog signal and alarm levels at the fire and gas system.

Maintenance and Troubleshooting

The infrared measurement principle has no consumable catalytic element, so routine work focuses on keeping the optical path clean and proving the response. Recommended practice includes:

  • Periodic gas tests at the interval set by the site procedure, with the results recorded
  • Inspection and cleaning of the optics and weather protection, particularly after sandstorms or heavy dust
  • Using HART diagnostics to read fault and status information before removing a detector from service

A persistent optics or beam-block fault usually indicates dirt, condensation or an obstruction in the measuring path.

Applications in Oman and the GCC

Gas processing plants, compressor stations, wellhead facilities and terminals across Oman and the GCC use Simtronics detectors in their fire and gas systems. The Simtronics GD10-P00-17DG-0XH-00 lets operators keep installed systems on the same detector family, which simplifies spares and training.

Supply from Seven Star LLC

Seven Star LLC supplies Simtronics gas detectors and accessories for replacements and system extensions. Send the full configuration code from the installed unit, and our team will confirm the match.

Ordering Information

To order the Simtronics GD10-P00-17DG-0XH-00 from Seven Star LLC, quote the full configuration code together with the quantity required. Our team confirms availability, certification documents and delivery to your site in Oman or anywhere in the GCC.

FAQ

What is the Simtronics GD10-P00-17DG-0XH-00?

It is a GD10P Series infrared gas detector from Teledyne Simtronics, configured for CH4 methane detection over the 0-100% LEL range with ATEX certification and HART output.

Which gas does the GD10P detector monitor?

This configuration monitors CH4 methane over the 0-100% LEL range.

Is the GD10-P00-17DG-0XH-00 certified for hazardous areas?

Yes. The detector carries ATEX certification for use in hazardous-area installations.

How does the detector communicate with the control system?

The detector provides HART communication, allowing digital interrogation, calibration and diagnostics over the measurement loop.

How can I order this detector from Seven Star LLC?

Send your request through our inquiry page with the full configuration code GD10-P00-17DG-0XH-00. Our team confirms availability, certification and delivery to your site.

Related Products

Datasheets & Documents
  • PDF Instruction Manual Simtronics GD10-P00-17DG-0XH-00 Infrared Gas Detector (GD10P Series) Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

On offshore platforms and gas plants the Simtronics name is tied to one instrument above all: the GD10 infrared gas detector. The brand covers fixed gas detection and flame detection for hazardous areas. Seven Star LLC sources and supplies Simtronics gas detectors and flame detectors for fire and gas systems in Oman and the GCC. Recent documents for these products may also carry the Teledyne Gas and Flame Detection name.

Simtronics detectors listed

The GD10P is an infrared point gas detector for hydrocarbon gas, built around a solid-state infrared source; a separate version measures carbon dioxide. It is listed here both as a series and under one full order code, GD10-P00-17DG-0XH-00, which shows how much of the configuration sits in the code. The third item is the DM-TV6-T, a flame detector that works on three infrared wavelengths. Newer documents also use the designation DF-TV7 for this detector family.

Ordering Simtronics GD10 and flame detectors: what we need

Send the complete order code from the nameplate; for a GD10P that is the long string with all its groups. The groups in the code fix the configuration of the detector, and two detectors with different codes are not automatically interchangeable. Add the serial number, the target gas, the hazardous area certification your site requires (ATEX or IECEx, for example) and the cable entry thread. For a flame detector, give the exact type including the last letter, plus the mounting accessories needed.

Frequently Asked Questions

What is the Simtronics GD10-P00-17DG-0XH-00?
It is a GD10P Series infrared gas detector from Teledyne Simtronics, configured for CH4 methane detection over the 0-100% LEL range with ATEX certification and HART output.
Which gas does the GD10P detector monitor?
This configuration monitors CH4 methane over the 0-100% LEL range.
Is the GD10-P00-17DG-0XH-00 certified for hazardous areas?
Yes. The detector carries ATEX certification for use in hazardous-area installations.
How does the detector communicate with the control system?
The detector provides HART communication, allowing digital interrogation, calibration and diagnostics over the measurement loop.
How can I order this detector from Seven Star LLC?
Send your request through our inquiry page with the full configuration code GD10-P00-17DG-0XH-00. Our team confirms availability, certification and delivery to your site.