Brand: KRACHT
KRACHT AS 8 U 24 D2F / F Flow Difference Display
Description
Two meters, one display: AS 8 U 24 D2F / F
KRACHT AS 8 U 24 D2F / F is the D2F version of the AS 8 instrument: it connects to two volume counters and displays the flow of component A, the flow of component B and the difference A minus B. In a circuit with a supply meter and a return meter, the difference is the quantity actually consumed.
The code reads AS 8, U (voltage output), 24 (24 VDC supply), D2F (flow and difference display) and F (membrane keyboard).
Functions of AS 8 U 24 D2F / F
- Three display values selected with function keys F1, F2 and F3: flow A, flow B and A-B
- A density factor can be set for each volume counter, which allows mass computation instead of volume
- Each counter must deliver a square-wave signal; the instrument filters, converts and computes the values
- Two relays and an analogue output are available for downstream processing, for example 0 to 10 V or 0/4 to 20 mA as shown in the datasheet
- A 24 V encoder supply feeds both counters directly
- Programming is by menu through the three buttons of the membrane keyboard
Technical data of AS 8 U 24 D2F / F
| Parameter | Value |
|---|---|
| Type code | AS 8 U 24 D2F / F |
| Output signal | Voltage, plus-minus 10 V / 0 to 10 V / 2 to 10 V |
| Supply voltage | 24 VDC |
| Program version | D2F flow and difference display |
| Keyboard | Membrane keyboard (F) |
| Display | 7-segment LED, 13.2 mm, red, 0.000 to 9999 with floating point |
| Power consumption | approx. 3.5 W |
| Sensor supply | 24 VDC plus/minus 20 percent, 50 mA |
| Relays | 2 relay contacts, 24 V / 1 A |
| Digital inputs | 2, input amplitude min up to 9 V, max from 12 V |
| Counter input frequency | 1 Hz to 2500 Hz |
| Front frame | 96 x 48 mm (DIN 43700) |
| Installation depth | approx. 122 mm with connector strip |
| Panel cut-out | 92 x 45 mm |
| Protection | IP 54 with correct panel assembly |
| Operating temperature | 0 to 60 C |
| Weight | approx. 0.4 kg |
How AS 8 U 24 D2F / F differs from AS 8 A2F, D2C and the single-counter versions
D2F shows A minus B, the A2F version of the same page layout shows A plus B, and D2C shows volume and difference rather than flow. The standard, DOS, RP and ZM programs use one counter only. Choosing D2F therefore always implies two counters and two density factors.
The datasheet example uses component A at 10 l/min and component B at 5 l/min, which gives a difference of 5.00 l/min on the display. This code is the 24 VDC version with a voltage output.
Applications of AS 8 U 24 D2F / F in industry
The classic use is consumption measurement on circulation systems: one counter in the supply line and one in the return line of a diesel engine, a burner or a hydraulic motor with case drain. The display subtracts the return from the supply, which yields the true consumption without calculating by hand. Test benches in Oman for engines and compressors use this approach to log fuel or oil use.
With a density factor entered for each counter, the difference can be displayed as mass flow, relevant when fuels of different density are compared.
Imagine a burner that is fed from a ring main. The supply counter reads 38 l/min and the return counter 31 l/min; the unit shows 7.00 l/min as the difference, and that is what the burner actually burns. Without the second counter the supply figure would overstate consumption by the circulating flow. The same arrangement works for hydraulic motors with a case drain, where the drain line is measured separately and subtracted.
Because the unit can toggle between flow A, flow B and A-B at the press of a key, a service engineer can use it as a quick diagnostic: if the two flows should be equal and are not, a leak or a blockage is present between the two measuring points.
Selection and wiring
Both counters need compatible 24 V incremental signals within 1 Hz to 2,500 Hz. The encoder supply provides 24 V at 50 mA in total, so check the combined current of two sensors. The analogue output can feed a recorder or PLC with the difference value.
A 24 VDC supply version suits cabinets and mobile test rigs; choose the 230 V or 120 V code when the instrument is to run from mains.
For accurate differences, the two counters should be of the same type and size. A small difference between two large flows is sensitive to the accuracy of each counter, so do not expect better difference accuracy than the sum of both tolerances relative to the difference itself.
Mounting and set-up of AS 8 U 24 D2F / F
Mount in a 92 x 45 mm cut-out; allow 122 mm of depth for the connector strip. Wire counter A and counter B to their inputs, set the pulse factor of each, set densities if mass is required, and run a check with known flows. Confirm that the difference stays at about zero when both counters see the same flow.
Label the two input cables A and B at both ends. Swapping them reverses the sign of the difference, and this is the most frequent error found at commissioning.
Maintenance
No routine work is needed for the instrument. If the difference drifts, check which counter has changed with temperature or wear, since both meters add their own tolerance to the difference.
Ordering and related
Order AS 8 U 24 D2F / F with two matching volume counters. Related electronics: AS 8 U 230 PUR / F for ratio control, AS 8 I 24 RP and AS 8 U 230 DOS / F.
Documents and quotation
The Electronics datasheet is attached. Send AS 8 U 24 D2F / F and the quantity as an RFQ to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.
Other Models in the Kracht As8 Electronics Range
Seven Star LLC supplies models from the Kracht As8 Electronics range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT AS 8 I 24 ZM / F Cylinder Stroke Measuring Unit | Flow Computers | View details |
| KRACHT AS 8 U 230 DOS / F Dosing Controller 230 V | Flow Computers | View details |
| KRACHT AS 8 I 24 RP Flow and Speed Controller 24 VDC | Flow Computers | View details |
| KRACHT AS 8 U 24 D2F / F Flow Difference Display | Flow Computers | You are viewing this model |
| KRACHT AS 8 U 230 PUR / F Mixing Ratio Controller | Flow Computers | View details |
| KRACHT SD 1 R 24 Plug-On Flow Display Square-Wave Output | Flow Computers | View details |
Datasheets & Documents
- Datasheet KRACHT AS 8 U 24 D2F / F Flow Difference Display Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT AS 8 U 24 D2F / F Flow Difference Display
Answers from our engineering team on installation, compatibility and integration.
01What does KRACHT AS 8 U 24 D2F / F display?
The flow of component A, the flow of component B and the difference A-B, switched with function keys F1 to F3.
02How many volume counters does AS 8 U 24 D2F / F need?
Two, each delivering a square-wave signal to its own input.
03Can AS 8 U 24 D2F / F display mass instead of volume?
A density factor can be set for each volume counter to enable density computation for mass determination.
04What supply does AS 8 U 24 D2F / F use?
24 VDC, with a 24 V encoder supply of 50 mA for the counters.
05What outputs does AS 8 U 24 D2F / F offer?
Two relays and a voltage analogue output, selectable such as 0 to 10 V.


















Reviews
There are no reviews yet.