Beamex 8003172 PGPH Shut-off Valve Assembly
Description
Beamex 8003172 PGPH shut-off valve assembly
Beamex 8003172 is the spare shut-off valve for the Beamex PGPH high pressure pneumatic calibration pump. It is a complete assembly: the shut-off valve mechanism with a preassembled handwheel and its seals. The maker states that it can be replaced easily in the PGPH pump when the original is broken. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
In the PGPH connection drawing the shut-off valve sits between the pump and the measurement circuit that holds the calibrator, the device under test, the fine adjust and the release valve. Its single task is to isolate the pump from that circuit.
Role of the valve in a calibration run
The manual’s operating sequence uses the valve twice. During preparation it is opened by turning counterclockwise, with the release valve also open, so the whole circuit sits at atmospheric pressure. During calibration the operator pumps with the valve open, then closes it clockwise so that the test circuit is sealed away from the pump. From that point pressure is trimmed only with the fine adjust handwheel and lowered with the release valve.
The run ends by opening the shut-off and release valves again. If the valve cannot close completely, the fine adjust becomes hard to use and the reading drifts, because pressure leaks back toward the pump. The manual lists exactly this symptom: hard to fine adjust when the shut-off valve is not closed.
Because the valve decides when the pump is part of the circuit, it also affects how long a stable reading takes. Immediately after a pressure change the manual notes that stretching or shrinking of the measurement hose and thermodynamic effects may shift pressure slightly; the correct response is to trim with the fine adjust, not to reopen the valve and pump again.
Data table for the 8003172 application
| Item | Detail |
|---|---|
| Part number | 8003172 |
| Description | PGPH shut-off valve spare assembly |
| Includes | Valve mechanism, preassembled handwheel and seals |
| Open direction | Counterclockwise |
| Close direction | Clockwise |
| Pump pressure range | Minus 0.95 bar to 140 bar / minus 14 psi to 2000 psi |
| Safety pressure | 180 bar / less than 2600 psi |
| Built-in relief valve | Yes |
| Pressure medium | Clean air |
| Pump dimensions, lever down | 178 x 540 x 270 mm (H x L x W) |
| Pump dimensions, lever up | 506 mm high x 450 mm long |
| Weight | 7.1 kg / 15.7 lb |
How 8003172 differs from other PGPH service parts
The PGPH has three easily confused moving parts: the shut-off valve, the release valve and the fine adjust. 8003172 replaces only the first. It is heavier on content than the 8003176 output connector, which is a threaded outlet body with a plug, and it is a targeted repair compared with the 8003180 service seal kit, which renews main piston seals and others across the pump. If the valve turns but still leaks, the seals within this assembly are the target; if the pump will not pressurize at all, check connectors and O-rings first.
Troubleshooting before ordering
The manual’s troubleshooting table for a pump that is hard to pressurize starts with simple items: shut-off valve not open, release valve not closed, a missing or broken O-ring in the pressure connectors, the pressure and vacuum selector in the wrong position, or a pipeline jammed by impurities. For the jammed case, open the clean-out bolt at the bottom of the pump and clean it.
Valves that are hard to turn are often over-tightened after the previous calibration: the manual advises not to close shut-off valves and handles too tightly, and to lubricate threads when needed. A new valve also needs a short running-in period.
The manual also lists the fine adjust troubleshooting items that can be mistaken for valve faults: connections that are not tight, a missing O-ring in a pressure connector, an instrument thread whose end surface is not smooth, where a PTFE washer is suggested, and impurities inside the fine adjust volume. Rule these out first.
Use in Oman and GCC calibration work
The PGPH is a bench pump for instrument technicians who calibrate gauges and transmitters in the range of a few mbar to 140 bar. It appears in refinery instrument shops, gas plant workshops, water utility test benches and the metrology rooms of manufacturers. In hot climates the elastomer seals inside valves age, so seal-bearing assemblies like this one are a normal consumable over a pump life.
Heavy use shortens seal life, so teams that run the pump daily often stock the valve assembly together with the service seal kit. A single spare avoids a long wait for a workshop pump, which is awkward when a plant shutdown has a fixed calibration window.
Replacement and test
Release all pressure, open the valve, and take the old assembly out. Fit 8003172 and run the valve through its full travel by hand. Then perform the leak tests from the manual: at full scale pressure of 140 bar record the reading after five minutes and after ten; if the fall divided by the five-minute reading is less than 1 percent the system is leak free. For vacuum, a fall of less than 1 kPa between five and ten minutes at minus 0.95 bar is the pass criterion.
Make sure a reliable pressure indicator is connected and that the 180 bar safety pressure is never exceeded.
Documents and quotation
The PGPH instruction manual serves as the datasheet for Beamex 8003172. To request a quotation, send an RFQ to Seven Star LLC with part number 8003172, the quantity required and the PGPH serial number if known.
Documentation and Compliance
Industrial buyers often need more than the hardware. When you order the Beamex 8003172, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Beamex process, pressure & temperature calibrators items can be checked against the bill of materials quickly.
Other Models in the Pgph Spares Range
Seven Star LLC supplies models from the Pgph Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Beamex 8003176 PGPH Output Connector G1/4 | Process, Pressure & Temperature Calibrators | View details |
| Beamex 8003172 PGPH Shut-off Valve Assembly | Process, Pressure & Temperature Calibrators | You are viewing this model |
Datasheets & Documents
- Datasheet Beamex 8003172 PGPH Shut-off Valve Assembly Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 8003172 PGPH Shut-off Valve Assembly
Answers from our engineering team on installation, compatibility and integration.
01What does Beamex 8003172 contain?
It contains the shut-off valve mechanism with a preassembled handwheel and seals, replacing the complete valve in the PGPH pump.
02Which direction closes the PGPH shut-off valve?
Clockwise closes it and counterclockwise opens it, as given in the operating steps of the manual.
03What problem appears when the shut-off valve does not close?
The fine adjust becomes hard to use and pressure drifts, because the circuit stays connected to the pump.
04What leak criterion does the manual give?
At 140 bar, compare readings after five and ten minutes; a fall of less than 1 percent means the system is leak free.
05Is 8003172 the same as the PGPH output connector?
No. The output connector is 8003176. This part is the shut-off valve assembly that isolates the pump from the test circuit.