Brand:

Beamex 8036840 Thermocouple Plug Set, IEC Colors

Description

Beamex 8036840 thermocouple plug set (IEC) overview

The Beamex 8036840 is a thermocouple plug set with IEC color coding. It includes plugs for types R/S, E, J, K, N and T and is compatible with all Beamex MC calibrators.

The colors follow the IEC convention listed by Beamex: black for type J, brown for T, orange for R/S, pink for N, green for K and purple for E.

This page describes Beamex 8036840 for buyers who need the exact order code. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key features of the thermocouple plug set (IEC)

  • Six plugs for thermocouple types R/S, E, J, K, N and T
  • IEC color coding
  • Compatible with all Beamex MC calibrators
  • Quick identification of the thermocouple type at the connector

Standard delivery and contents according to Beamex:

  • Thermocouple plugs for types R/S, E, J, K, N and T

Technical specifications of Beamex 8036840

Order code 8036840
Color code IEC
Types included R/S, E, J, K, N, T
Black Type J
Brown Type T
Orange Type R/S
Pink Type N
Green Type K
Purple Type E
Compatibility All Beamex MC calibrators

All values are taken from Beamex documentation. Items not shown here are not stated in the manufacturer source and are therefore left out.

Typical applications in Oman and the GCC

Thermocouple calibration needs the right plugs to connect sensors to a calibrator or a measurement input. Instrument teams in oil and gas, power, water and manufacturing sites across Oman and the GCC use plug sets such as the thermocouple plug set (IEC) (8036840) when they check thermocouple loops, temperature transmitters and furnace controls.

Plugs in a standard color code help a technician identify the thermocouple type at a glance.

Selection and compatibility notes for 8036840

Choose between ANSI and IEC color codes according to your plant standards. 8036840 covers six thermocouple types, so confirm that the types you use are included.

Always confirm the type of the thermocouple on the sensor tag or datasheet before connecting, because colors differ between standards.

Installation and commissioning

Push the plug into the calibrator thermocouple connector firmly with the correct polarity, then connect the sensor or extension wire. Allow the connection to reach thermal equilibrium before reading.

Select the same thermocouple type in the calibrator as the plug in use. See the Beamex manuals for the calibrator you use with 8036840.

Maintenance and care

Keep the pins clean and straight, and replace any plug with a loose or corroded contact. Store plugs in a small box so that they do not get lost.

A worn plug can cause an offset in the measured temperature, so replace it when in doubt.

Related products and ordering notes

Beamex lists these related items, each with its own order code:

  • 8036830 thermocouple plug set (ANSI)
  • 8036820 test leads TC to banana male
  • 9250000 MC6-Ex intrinsically safe calibrator

Beamex is a Finnish maker of calibration equipment, and its manuals and product pages are the reference for every figure on this page. Always check the manufacturer’s current documentation before putting any accessory or spare part into service.

Seven Star LLC works with industrial maintenance, procurement and calibration teams, so requests that include the full order code, the quantity and the delivery location can be answered quickly. Order codes are often the only reliable way to separate similar-looking accessories from different product generations.

Plants in the region usually plan calibration work around shutdowns, turnarounds and seasonal maintenance windows. Ordering accessories and spare parts well before the work starts avoids waiting for a missing seal, hose or cable when the plant is already offline, and it is cheaper than expediting a single item at the last minute.

Good calibration practice also depends on traceability. Records of the reference equipment, its certificate, the environmental conditions and the as-found and as-left results are what auditors and clients ask for. Accessories do not replace the calibration of the reference itself, but a worn hose, a leaking seal or a damaged cable can spoil an otherwise good measurement, which is why consumables should be replaced on a schedule rather than only after a failure.

When you compare quotations, make sure the order code is identical. Calibration accessories from the same manufacturer often differ only by thread, length or pressure rating, and a similar-looking item with a different code may not be compatible with your equipment. Keep the code on the purchase order, the goods receipt note and the maintenance record so that the same item can be reordered later.

Frequently asked questions about 8036840

Which types does the 8036840 set cover? The set holds plugs for thermocouple types R/S, E, J, K, N and T, according to Beamex.

What color is a type K plug in this set? A type K plug is green in the IEC color coding used by this set, according to Beamex.

Which calibrators are supported? All Beamex MC calibrators, according to Beamex.

How does it differ from 8036830? Only the color coding. 8036830 uses ANSI colors while 8036840 uses IEC colors for the same six types.

Which standard should I choose? Choose the color code that matches your plant thermocouple wiring, and verify types on the sensor label before connecting.

Documents and quotation

The official Beamex MC6-Ex User Manual is attached to this page as a PDF. Its thermocouple measurement sections explain how thermocouple plugs are connected to the calibrator TC terminal. Quote order code 8036840 in your request and we will confirm compatibility with your unit in a written quotation.

Quote Beamex 8036840 exactly as written when you contact us, so that the correct item is quoted the first time. Delivery to Oman and to other GCC countries is arranged for each order, and any questions about packaging, documentation or alternative items can be raised in the same message.

Datasheets & Documents
  • PDF Datasheet Beamex MC6-Ex User Manual (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 8036840 Thermocouple Plug Set, IEC Colors

Answers from our engineering team on installation, compatibility and integration.

01Which types does the 8036840 set cover?
The set holds plugs for thermocouple types R/S, E, J, K, N and T, according to Beamex.
02What color is a type K plug in this set?
A type K plug is green in the IEC color coding used by this set, according to Beamex.
03Which calibrators are supported?
All Beamex MC calibrators, according to Beamex.
04How does it differ from 8036830?
Only the color coding. 8036830 uses ANSI colors while 8036840 uses IEC colors for the same six types.
05Which standard should I choose?
Choose the color code that matches your plant thermocouple wiring, and verify types on the sensor label before connecting.