Brand:

Beamex 8003176 PGPH Output Connector G1/4

Description

Beamex 8003176: the replaceable G1/4 output connector

Beamex 8003176 is the PGPH output connector with a G1/4 inch thread. The PGPH high pressure pneumatic pump has two hand-tightened pressure output connectors, one for the calibrator and one for the instrument being calibrated, and this part is the spare for either of them. It has an internal G1/4 inch female thread with bottom sealing and arrives with a pre-assembled G1/4 inch male plug. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

The black body in the product picture carries an orange G1/4 marking, which makes it easy to tell from other threaded adaptors in a workshop drawer.

Technical data

Item Detail
Part number 8003176
Description PGPH output connector G1/4
Thread Internal G1/4 inch female, bottom sealing
Supplied plug Pre-assembled G1/4 inch male plug
Tightening Hand tightened
Number of output connectors on pump Two, equivalent to each other
Host pump pressure range Minus 0.95 bar / minus 14 psi to 140 bar / 2000 psi
Safety pressure of pump 180 bar
Pressure medium Clean air
Pump weight 7.1 kg / 15.7 lb
Pump operating temperature 0 to 50 degrees C
Pressure resolution 0.1 mbar / 0.002 psi

What the connector does on the PGPH

The PGPH generates gauge pressure up to 140 bar or vacuum down to minus 0.95 bar using clean air, and it is used for calibrating gauges, transducers and other pressure instruments. Everything the operator connects, whether a hose to a calibrator high pressure module or a hose to the device under test, passes through these outlets.

The manual treats the two outlets as equivalent, and every unused connector must be plugged. That is why the part ships with its own male plug: after replacing a damaged outlet with 8003176 you can keep one port sealed while the other carries the test circuit.

In practice the outlet takes more abuse than any other pneumatic part of the pump. Technicians swap between hose sets, tighten and loosen under time pressure, and sometimes cross-thread a fitting. Because the manual specifies hand tightening, a tool should never be needed to seat a hose; if one is, inspect the thread of the outlet for damage before forcing it.

How 8003176 compares with other PGPH spares

The PGPH spare range targets different wear points. The shut-off valve assembly 8003172 isolates the pump from the measurement circuit and is a mechanism with handwheel and seals. The service seal kit 8003180 renews seals across the pump. 8003176 is purely the connector body: its job is thread integrity and a bottom-sealed joint. Choose it when the G1/4 thread of an outlet is damaged, cross-threaded or leaking at the seat, and when other pump functions work normally.

Applications in Oman and GCC instrument shops

A high pressure pneumatic pump of this size, at 7.1 kg, is a bench and van tool for calibration laboratories working on pressure gauges, transmitters and switches for oil and gas production, gas distribution, water utilities and industrial plants. The PGPH can also pull vacuum, so it appears in jobs on compound gauges and absolute transmitters.

Because the outlets take repeated hand tightening on hose connections, thread wear is predictable. A spare outlet in the toolbox is a cheap way to avoid cancelling a calibration visit.

Typical field setups are a PGPH connected through a T arrangement to a transmitter under test and to the reference module of a documenting calibrator, with the second outlet plugged. When the plugged outlet is the damaged one, the unit can still be used, but a leak at a plug seat spoils stability readings, so repairing it promptly is better than working around it.

Installation and checks

Depressurize the pump, open the release valve and shut-off valve, and unscrew the damaged outlet. Fit 8003176, tighten by hand as the manual states for the output connectors, and plug any outlet that is not in use. Then perform the manual’s leak check: pressurize to the test level, close the shut-off valve and watch the reading for a drop.

Do not exceed the 180 bar safety pressure of the pump, and use only hoses suited to the pressure involved. The manual gives the working pressure of its hoses as 630 bar at 50 degrees C with a bursting pressure of 1950 bar at 20 degrees C.

A good test after fitting is a stability check: build a moderate pressure, close the shut-off valve and observe the reading for several minutes. A drift larger than your calibration procedure allows points to a leak at the new connector, the plug or the hose joint; wetting each joint with leak detection fluid helps to locate it.

Maintenance notes

Keep the clean-out connection plugged and check that nothing but clean air enters the pump. Grease for the fine adjust stem, order code 0005180, is the maker’s listed lubricant for that part and and is not a thread sealant.

Inspect the outlet thread and bottom sealing face whenever a hose is changed. Replace the connector if the thread shows burrs or the plug no longer seals.

Related items for the same PGPH pump

Order codes named in the PGPH manual include the carrying case 8003315, the service seal kit 8003180, the fine adjust grease 0005180, a 400 bar hose and connector set 8003380 for connecting the instrument to be calibrated, and the set 8003365 for a calibrator high pressure module. Those sets are not needed when the module used is an EXT external pressure module.

Documents and quotation

The PGPH instruction manual is provided as the datasheet for Beamex 8003176. To receive a quotation, send an RFQ to Seven Star LLC stating part number 8003176, the quantity and, if possible, the pump serial number.

Other Models in the Pgph Spares Range

Seven Star LLC supplies models from the Pgph Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Beamex 8003176 PGPH Output Connector G1/4Process, Pressure & Temperature CalibratorsYou are viewing this model
Beamex 8003172 PGPH Shut-off Valve AssemblyProcess, Pressure & Temperature CalibratorsView details
Datasheets & Documents
  • PDF Datasheet Beamex 8003176 PGPH Output Connector G1/4 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 8003176 PGPH Output Connector G1/4

Answers from our engineering team on installation, compatibility and integration.

01What thread does Beamex 8003176 have?
It has an internal G1/4 inch female thread with bottom sealing, and a pre-assembled G1/4 inch male plug is included.
02How many output connectors does the PGPH have?
Two hand-tightened outputs, one for the calibrator and one for the instrument being calibrated, which the manual treats as equivalent.
03Can the connector be replaced if damaged?
Yes. The maker states the connector can be easily replaced if damaged.
04What pressure range does the host pump cover?
The PGPH covers minus 0.95 bar to 140 bar, with a 180 bar safety pressure and a built-in relief valve.
05Does 8003176 replace the shut-off valve?
No. The shut-off valve is a separate assembly, 8003172; this part is only the outlet connector.