Brand: Beamex
Beamex 8129720 Accessory Holder and Heat Shield MC6-T660
Description
Beamex 8129720 accessory holder and heat shield for MC6-T660
Beamex 8129720 combines two items for the MC6-T660 high temperature calibrator: a stainless steel accessory holder that fixes to the back of the instrument, and a sensor heat shield plate with a mounting support. The holder keeps three inserts, the insert removal tool and the power cord together with the calibrator while it is carried. The heat shield is used when you calibrate above 150 degrees C and protects the handle and the internal structures of the instrument being calibrated.
MC6-T660 conditions that call for 8129720
| Item | MC6-T660 value |
|---|---|
| Temperature range | 50 to 660 degrees C |
| Control | Active triple zone temperature control |
| Heating time | 50 to 660 degrees C in 15 min |
| Cooling time | 660 to 50 degrees C in 35 min; 660 to 100 degrees C in 25 min |
| Outer dimension (brochure) | 24.5 mm |
| Immersion depth | 150 mm |
| Weight | 8.6 kg |
| Power | 1560 W at 115 V or 230 V |
| Safety | Hot indicator light, tilt sensor, independent overheat protectors |
Contents and fitting of 8129720
The kit comprises the holder and the heat shield plate with mounting support. When it is ordered together with an MC6-T660 it is attached at Beamex; for a separate order the assembly instructions are in the MC6-T user manual. The shield is meant for the sensor being calibrated: the process sensor often has a handle and a head or transmitter that cannot tolerate heat conducted up the stem from a block at 660 degrees C.
Three inserts: how to use the capacity of 8129720
The MC6-T660 inserts are available as multi-hole types and a blank. The brochure shows MH1 to MH4 multi-hole inserts and a blank insert for the MC6-T660, so three carrying positions let you travel with the combinations most common in your plant. Insulation shields for the MH1 insert and for the blank insert are sold separately in packs of five.
The MC6-T660 that 8129720 serves
The MC6-T660 generates 50 to 660 degrees C with active triple zone control for a good temperature gradient. Beamex gives a display uncertainty of plus or minus 0.2 degrees C at 50 degrees C, 0.3 degrees C at 420 degrees C and 0.5 degrees C at 660 degrees C with the internal reference, and stability of plus or minus 0.02, 0.03 and 0.04 degrees C at the same points. Axial uniformity at 40 mm is plus or minus 0.25 degrees C at 420 degrees C and 0.40 degrees C at 660 degrees C. Because the block runs so hot, the holder and shield are the practical protection for the person carrying it and for the sensor under test.
Safe use at high temperatures
The MC6-T660 has a tilt and orientation sensor which switches off heating and starts the fan if the unit is tilted too much or falls on its side, and a red light that warns when the block is hot. Keep the instrument upright and respect these features. The brochure also names independent overheat protectors, which work without the main processor, as an additional protection. Mount the 8129720 heat shield before the block starts to heat for work above 150 degrees C, and allow the cooling times listed above before you pack the holder; 660 degrees down to 50 degrees C takes about 35 minutes.
How 8129720 differs from 8129710
Compared with the MC6-T150 holder 8129710, the 8129720 carries three inserts instead of two, comes as a kit with a heat shield plate and mounting support, and is intended for the heavier 8.6 kg block, whose power demand is 1560 W. The two parts are specific to their calibrator and should not be mixed.
Heat shield 8129720 in the calibration routine
A typical routine with the 8129720 starts with choosing the insert whose bores suit the process sensors, then fitting the heat shield plate on its mounting support so it sits between the block and the handle of the sensor. Insert the reference and the sensors under test, let the MC6-T660 reach the set point and stabilize for about ten minutes as given in the stability time of the brochure, and record the calibration. Afterward, let the block cool; the brochure lists 660 to 100 degrees C in 25 minutes. Because the shield protects the handle and internal structures of the sensor, it also lowers the risk of damaged cable insulation or transmitter electronics on sensors with heads.
Ordering notes and plant use for 8129720
The 660 degrees range reaches furnace, flue-gas and steam instruments in power stations, refineries and process heaters. Technicians in those plants, who wait about 15 minutes for the block to go from 50 to 660 degrees C, appreciate that the 8129720 keeps the inserts, the removal tool and the cord with the block and gives a clear way to protect the instrument handle during long soaks.
Because the holder and shield are one kit, a single order code, 8129720, covers both items, so you do not need to order the shield separately. When a new MC6-T660 is bought, ask for the kit to be factory-fitted; for a unit in service, the user manual gives the assembly instructions. The spare fuse sets for the MC6-T660 are separate parts with codes 8129770 for 115 V and 8129760 for 230 V, the insert removal tool is 8129750, and the transport case is 8129900. Together with the holder they make up the usual accessory kit for a high temperature dry block.
Documents and quotation
The MC6-T brochure lists the accessory holder and heat shield as optional accessories. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ naming Beamex 8129720, the quantity and the MC6-T660 serial number if you need fitting advice.
Datasheets & Documents
- Datasheet Beamex 8129720 Accessory Holder and Heat Shield MC6-T660 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 8129720 Accessory Holder and Heat Shield
Answers from our engineering team on installation, compatibility and integration.
01What is in Beamex 8129720?
The kit has a stainless steel accessory holder for the MC6-T660 and a sensor heat shield plate with a mounting support.
02How many inserts does the 8129720 holder carry?
Three inserts, together with the insert removal tool and the power cord.
03When should the 8129720 heat shield be used?
Use it when calibrating at temperatures above 150 degrees C to protect the handle and internal structures of the instrument being calibrated.
04Does the 8129720 fit the MC6-T150?
No. The MC6-T150 uses the separate holder 8129710, which carries two inserts and has no heat shield.
05Where are the installation instructions for 8129720?
If not factory fitted, the assembly instructions are in the MC6-T user manual.