- Automation & ControlView all 2,718 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Beamex
Beamex 9430020 MC6-T150 Multifunction Temperature Calibrator
Description
Overview of Beamex MC6-T150 multifunction temperature calibrator and communicator Beamex 9430020
The Beamex MC6-T150 (product code Beamex 9430020) combines a temperature dry block with a built-in multifunction process calibrator and communicator. It generates temperatures from minus 30 to 150 degrees C and can also measure and simulate temperature and electrical signals, measure pressure through external modules and communicate with HART, FOUNDATION Fieldbus H1 and Profibus PA instruments.
Dual-zone heating and cooling control gives a stable and uniform temperature in the insert, and a control algorithm that heats and cools quickly without overshoot saves time on the bench or in the field. The process calibrator side runs from the internal battery, so electrical work can continue without mains power. An accredited calibration certificate is included as standard.
This page describes Beamex MC6-T150 multifunction temperature calibrator and communicator for buyers who need the exact part number Beamex 9430020. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the data below is taken from the manufacturer published product pages and brochures.
Key features of 9430020
- Temperature generation from minus 30 to 150 degrees C with dual-zone heating and cooling.
- Display uncertainty with internal reference of plus or minus 0.15 degrees C and stability of plus or minus 0.01 degrees C, per the manufacturer brochure.
- Built-in field communicator for HART, FOUNDATION Fieldbus H1 and Profibus PA instruments.
- Safety features: tilt sensor, warning light and stand-alone overheating protection.
- Documenting calibrator that works with Beamex CMX and LOGiCAL software, with wireless transfer over Bluetooth.
- Stability control that follows two-sigma stability criteria so only stable readings are accepted.
Technical specifications for 9430020
| Product code | 9430020 (MC6-T150) |
|---|---|
| Temperature range at 23 degrees C | -30 to 150 degrees C (-22 to 302 degrees F) |
| Display uncertainty, internal reference | plus or minus 0.15 degrees C |
| Stability (30 minutes, 2 sigma) | plus or minus 0.01 degrees C |
| Axial uniformity at 40 mm / 60 mm | plus or minus 0.05 / 0.07 degrees C |
| Radial uniformity | plus or minus 0.01 degrees C |
| Hysteresis | plus or minus 0.03 degrees C |
| Display resolution | 0.001 degrees C / F / K |
| Immersion depth | 150 mm (5.9 in) |
| Insert outer dimension | 30 mm (1.18 in) |
| Heating time | 23 to 150 degrees C: 19 min |
| Cooling time | 150 to 23 degrees C: 17 min; 23 to -30 degrees C: 23 min; 150 to -30 degrees C: 37 min |
| Stabilization time | 5 to 10 min |
| Dimensions (D x W x H) | 322 x 180 x 298 mm |
| Weight | 9.4 kg (20.7 lb) |
| Power requirements | 115 V or 230 V plus or minus 10 percent, 50/60 Hz, 380 W |
| Mains fuse | T 3.15 A 250 V |
| Display | 5.7 inch TFT touch screen |
| Battery | Rechargeable lithium-ion, 4300 mAh, 11.1 V |
| Warranty | 3 years; 1 year for the battery pack |
All values above come from the manufacturer documentation and may change with later revisions. Please quote 9430020 when you need the matching datasheet or a confirmation of the current revision.
Typical applications in Oman and the GCC
Instrument workshops in Oman use dry-block calibrators to check temperature transmitters and RTD probes pulled from process units, and the sub-ambient range suits chilled water, LNG-related and cold storage sensors.
Because the unit also measures electrical signals and communicates with smart devices, one MC6-T150 can cover a full temperature loop check from probe to transmitter.
Typical sectors are oil and gas production and processing, refining and petrochemicals, power generation, desalination and water treatment, pharmaceutical and food manufacturing, and calibration service providers across Oman, the UAE, Saudi Arabia, Qatar, Kuwait and Bahrain.
Selection and compatibility notes for 9430020
Inserts are chosen to match the sensors under test and are ordered separately; the insert removal tool 8129750 must be used to take them out. The model for the 50 to 660 degrees C range is the MC6-T660 (9430010), so select the T150 when the work is at or below 150 degrees C, including sub-ambient points down to minus 30 degrees C.
A reference sensor such as the RPRT or the SIRT-155 (for short and flanged sanitary sensors) can be connected for traceable work. Spare mains fuses are available as 8129780, and a transport case as 8129900. Battery-powered operation covers all functions except temperature generation and R3 measurement.
Before ordering 9430020, confirm the model and, where relevant, the serial number or option code of the instrument it will serve. Confirm voltage, plug type, thread type or pressure rating as applicable, and check the manufacturer documentation for the firmware or hardware revision of the equipment.
If an item looks similar but carries a different part number, do not assume interchangeability. A short note of the calibrator model and application lets us confirm the match for 9430020 before it is supplied.
Installation and commissioning of 9430020
Unpack 9430020 and check the delivery against the standard accessories list before taking it to site. Charge the battery fully before the first job, confirm the date, time and language in the Settings view, and read the user manual for your firmware version. Connect test leads or pressure hoses only when the unit is idle, and always check the connection diagram shown on the screen for the selected function.
For pressure work attach the pressure module, a hose set suited to the pressure range and the right fittings, and vent the system slowly. For loop work use the built-in loop supply and keep the maximum input voltage of the calibrator in mind. After commissioning, run a short verification against a known reference so the first documented result is trustworthy.
Maintenance and care
Keep the calibrator clean and dry, store it in its case and avoid leaving it in a hot vehicle. Check the condition of test leads, clips and pressure hoses before each campaign, because worn accessories are the most common cause of unstable readings. Follow the recalibration interval set by your quality system, and use the accredited certificate delivered with 9430020 as the starting point for the history.
Update firmware and device description files only from the manufacturer download area, and record the version in your calibration log. If a part such as a battery, charger, case or fuse needs replacing, order the exact spare part number rather than a lookalike.
Calibration is only as useful as its records. Keep a log of serial numbers, certificate dates, replacement parts and any faults, and store the manufacturer documents with the equipment. This makes audits easier, helps predict when spares will be needed, and shortens the time needed to prepare a purchase request when a part has to be replaced at short notice.
Related products and ordering notes for 9430020
Typical companions for 9430020 are a protective case, a spare battery pack, pressure hoses and fittings, reference temperature sensors and calibration management software. Many of these are separate part numbers, so list them in the same enquiry to receive one consolidated reply.
Hard-to-find and discontinued spare parts are a daily topic for maintenance planners in oil, gas, power and water facilities. When a plant standardises on one calibrator family, a small stock of the exact spares is far cheaper than a day of lost production, and an early enquiry gives the supplier time to confirm availability and shipping options to Oman and neighbouring countries.
Please note that Seven Star LLC prepares each quotation for 9430020 against the exact part number, so a request that quotes the number and the quantity is answered faster than a general description.
The part number 9430020 should be quoted exactly as printed in this page, because accessories and spares with similar descriptions often differ by one digit.
When ordering 9430020 for a fleet of calibrators, mention the calibrator models in use so that compatibility can be checked before the quotation is issued.
Frequently asked questions about 9430020
- What range does 9430020 cover? The MC6-T150 generates temperatures from minus 30 to 150 degrees C. For 50 to 660 degrees C the manufacturer offers the MC6-T660.
- Does it work without mains power? Only the process calibrator functions run from the battery. Temperature generation and R3 measurement need mains voltage, according to the brochure.
- Which fuse does it use? The mains fuse size is T 3.15 A 250 V for both 115 V and 230 V, and a spare fuse kit is sold as 8129780.
- Can it communicate with smart instruments? Yes. It has a built-in communicator for HART, FOUNDATION Fieldbus H1 and Profibus PA instruments, with some functions optional.
- Is a calibration certificate included? Yes. An accredited calibration certificate is included as standard according to the manufacturer.
Documents and quotation
The manufacturer brochure for this product family is available as a datasheet document on this page. To request a quotation, send the RFQ to Seven Star LLC with the part number 9430020, the quantity required, the delivery location and any related items. We will confirm availability and lead time for 9430020 and reply with commercial terms.
Datasheets & Documents
- Datasheet Beamex 9430020 MC6-T150 Multifunction Temperature Calibrator Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 9430020 MC6-T150 Multifunction Temperature
Answers from our engineering team on installation, compatibility and integration.
01What range does 9430020 cover?
The MC6-T150 generates temperatures from minus 30 to 150 degrees C. For 50 to 660 degrees C the manufacturer offers the MC6-T660.
02Does it work without mains power?
Only the process calibrator functions run from the battery. Temperature generation and R3 measurement need mains voltage, according to the brochure.
03Which fuse does it use?
The mains fuse size is T 3.15 A 250 V for both 115 V and 230 V, and a spare fuse kit is sold as 8129780.
04Can it communicate with smart instruments?
Yes. It has a built-in communicator for HART, FOUNDATION Fieldbus H1 and Profibus PA instruments, with some functions optional.
05Is a calibration certificate included?
Yes. An accredited calibration certificate is included as standard according to the manufacturer.


















Reviews
There are no reviews yet.