Brand:

Beamex 9010090 PGL Low Pressure Calibration Pump Only

Description

Beamex 9010090 PGL low pressure calibration pump (pump only)

Beamex 9010090 is the PGL, a screw-driven low pressure calibration pump for the range -400 to +400 mbar (-160 to +160 iwc). It does not use a lever: instead, a coarse adjust handwheel and a fine adjust knob each move a piston to change the volume of a closed circuit, and that volume change is what moves the pressure. The result is a very smooth, repeatable adjustment that is hard to achieve by pumping.

The 9010090 is the pump-only package: pump, user manual, 4 mm hex wrench, an opening tool for maintenance and the warranty terms. It is meant for technicians who already own a Beamex 40 bar hose and a carrying case. The design and materials were chosen to reduce the effect of ambient temperature swings on the generated pressure, which is why the PGL stays calm during a long calibration run.

Working principle of the 9010090

The PGL changes pressure by changing volume. Inside a closed system that is simple physics, and it has two practical consequences that the manual spells out. A system with a very large volume allows only small pressure adjustments, so you may not reach the full range. A system with a very small volume reacts strongly, and the pump can then go beyond the safety pressure of 4 bar (below 60 psi), which must never be exceeded. Keep the connected volume modest, up to about 20 ml for the datasheet figures, and always have a reference gauge connected.

9010090 specifications

Parameter Value
Order code 9010090 (pump only)
Pressure range -400 to 400 mbar, -160 to 160 iwc
Extended range, volume up to 20 ml -0.7 to 3.0 bar
Adjusting sensitivity less than 0.05 mbar (0.02 iwc)
Drift after 1 minute and readjustment less than 0.3 mbar per minute (0.12 iwc per minute)
Wetted parts Stainless steel, nitrile rubber, polyacetal
Dimensions 283 x 110 x 114 mm
Weight about 1.8 kg (4.0 lb)
Port G1/8 inch female with Bx G1/8 inch male fitting for Beamex 40 bar hose
Medium Air
Operating temperature 0 to 50 degrees C
Storage temperature -20 to 60 degrees C
Humidity below 95 %RH

The stability and sensitivity values apply only when the Beamex 40 bar pressure T-hose is used.

Calibration procedure with 9010090

Open the release valve by unwinding the fine adjust knob until two or three threads show, and unwind the coarse handwheel fully. Close the release valve by turning the knob to its middle position. Connect the calibrator and the device under test with a T-hose, and cancel the small pressure offset created by the connection with the fine adjust until the reading is 0. Approach each point with the coarse handwheel clockwise for higher pressure, then complete with the fine adjust and wait about one minute before re-trimming. For vacuum, begin with the handwheel turned clockwise to the maximum and work counterclockwise. Avoid direct sunlight, which can heat the setup and make the readings fluctuate.

Ergonomics: moving the cylinder and legs

The support legs can be loosened to rotate the cylinder, so the combined fine adjust knob and release valve falls on the left or right side of the pump. Left-handed technicians and tight bench layouts benefit from this. Replacement legs are listed as spare parts with code 8003730, and each kit contains one leg.

How 9010090 differs from the 9010095 complete kit

Pump data is identical. The 9010095 adds a 40 bar pressure T-hose (1.5 m) and a hard case (8003311) to the same pump, user manual and tools. Choose 9010090 for a replacement pump or when stock hoses and cases exist. Remember that the specification figures only hold with the Beamex T-hose, so a customer buying 9010090 on its own still needs a suitable hose set, for example the 8009550 T-hose set listed with the kit.

Maintenance and spare parts for 9010090

The manual lists the seal service kit 8003710, the coarse adjust handwheel 8003715, the coarse adjust service kit 8003720, the fine adjust service kit 8003725 and the support leg 8003730. Clean the pump only with a cloth damped with an alcohol-based solvent, a low concentration of hydrogen peroxide, or mild soapy water; strong detergents are excluded. A newer PGL launched in February 2023 is not compatible with the case and spare parts of the earlier PGL silver, so verify the model before ordering. Seal replacement touches four places: the coarse adjust piston, the fine adjust piston, the seal under the output fitting (a 16 mm wrench unscrews the fitting) and the seal under the end flange of the output fitting (TX20 screws). When refitting the end flange, the vent hole must point upward.

Where 9010090 is used in the field and workshop

Low pressure calibration is typical for differential pressure transmitters on flow and level services, draft gauges on boilers and furnaces, cleanroom pressure monitors and low range switches. Utilities in Oman and the wider GCC use the PGL where a 400 mbar window is sufficient and a lever pump would overshoot. In a laboratory, the same pump helps test barometric and small-range pressure sensors where a smooth, drift-free adjustment matters more than raw pressure. For vacuum work, the manual describes the opposite sequence: start with the release valve open and the coarse handwheel fully clockwise, close the valve, set the fine adjust mid-range, and step down by winding the handwheel counterclockwise.

Documents and quotation

The PGL user manual provides the delivery contents, specification table, operating steps and service chapters. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Please send an RFQ with Beamex 9010090, the quantity, and any T-hose or spare-part codes you need.

Selection Notes for the Beamex 9010090

When comparing the Beamex 9010090 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Beamex process, pressure & temperature calibrators range and confirm the correct order code before you commit.

Other Models in the Beamex Pgl Range

Seven Star LLC supplies models from the Beamex Pgl range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Beamex 8003715 PGL Coarse Adjust Handwheel Spare PartProcess, Pressure & Temperature CalibratorsView details
Beamex 8003730 PGL Support Leg Kit Spare PartProcess, Pressure & Temperature CalibratorsView details
Beamex 9010095 PGL Low Pressure Calibration Pump Complete KitProcess, Pressure & Temperature CalibratorsView details
Beamex 9010090 PGL Low Pressure Calibration Pump OnlyProcess, Pressure & Temperature CalibratorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Beamex 9010090 PGL Low Pressure Calibration Pump Only Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 9010090 PGL Low Pressure Calibration Pump

Answers from our engineering team on installation, compatibility and integration.

01What is the range of Beamex 9010090?
The PGL covers -400 to 400 mbar (-160 to 160 iwc), and with a connected volume up to 20 ml it can also work between -0.7 and 3.0 bar.
02Is a hose included with 9010090?
No. The pump-only delivery contains the pump, manual, 4 mm hex wrench, opening tool and warranty terms; the 9010095 kit adds a T-hose and case.
03What is the safety pressure of the PGL?
The safety pressure is 4 bar, below 60 psi, and it must not be exceeded even with a very small connected volume.
04Which parts of the 9010090 are wetted?
Wetted parts are stainless steel, nitrile rubber and polyacetal, and the medium is air.
05Can the 9010090 be adapted for left-hand use?
Yes, loosening the screws of both support legs lets you rotate the cylinder so the fine adjust knob sits on either side.