Endress+Hauser 50L Promag 50L Lap-Joint Electromagnetic Flowmeter

Description

Meet the 50L

Endress+Hauser 50L is the lap-joint, weight-optimized version of the Promag 50 line. TI00097D calls it the flowmeter with a weight-optimized sensor and a modular electronic concept, fully suitable for standard applications in the water and wastewater industry. Up to 30 percent less sensor weight, a reduced installation length that follows DVGW and ISO, and a nominal diameter range of DN 25 to 2400 are the headline facts.

Because the flanges below DN 350 are of the lap-joint type, they rotate, and misaligned pipework no longer forces the installer to drill new holes. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the 50L is quoted from the nameplate root.

50L at a glance

  • PTFE, polyurethane or hard rubber lining according to diameter
  • HART and PROFIBUS PA or DP communication
  • Quick Setup menus for fast commissioning
  • Compact or remote transmitter with two-line backlit display
  • Optional ambient range down to minus 40 degC for the transmitter

50L data

Parameter Value for 50L
Product root 50L, Proline Promag 50L (TI00097D, edition 19.17)
Positioning Weight-optimized sensor with a modular electronic concept
Sensor weight Up to 30 % less than a conventional sensor
Nominal diameters DN 25 to 2400 (1 to 90 inch)
Liner limits PTFE -20 to +90 degC (DN 25 to 300); polyurethane -20 to +50 degC (DN 25 to 1200); hard rubber 0 to +80 degC (DN 350 to 2400)
Measuring tube 1.4301/1.4306 to DN 300; 1.4301/1.4307 above
Electrodes 1.4435 (316L) or Alloy C22 (2.4602)
Minimum conductivity 5 microsiemens per cm; 20 for demineralized water
Pulse output accuracy 0.5 % of reading plus 1 mm/s; optional 0.2 % plus 2 mm/s
Supply 85 to 250 V AC; 20 to 55 V AC; 16 to 62 V DC
Communication HART, PROFIBUS PA/DP
Display Two-line backlit with push buttons
Ambient temperature, transmitter -20 to +60 degC; optional -40 to +60 degC
Protection class IP67 type 4X; IP20 type 1 with housing open
Commissioning Application-specific Quick Setups
Installation length Reduced, in accordance with DVGW/ISO

Where the 50L is used

Large water projects in the Gulf lay long pipelines through desert terrain, and crews have to install meters in chambers with only light lifting equipment. The lighter 50L answers that. Treated sewage effluent, desalinated water distribution, cooling-water circuits and reservoir feeders are typical jobs. PROFIBUS PA connectivity also fits plants that run a fieldbus-based water treatment DCS.

How 50L differs from other Promag 50 variants

Versus 50W, the 50L uses lap-joint flanges and weighs less, but the 50W covers up to DN 2000 with tantalum electrodes as an option while the 50L runs to DN 2400 and offers only 316L or Alloy C22. Versus 10L, which is the plain Promag 10 root of the same sensor idea, the 50L has a modular transmitter with Quick Setups, PROFIBUS and a 5 microsiemens conductivity limit instead of 50. The later Promag L 400 (5L4B) replaces the display with a touch version and adds a web server.

Ordering the 50L

Work from the nameplate of the existing meter and note size, liner, electrode, flange standard and pressure class. EN 1092-1 lap-joint flanges are available as PN 10 or PN 16, and stamped plate lap-joint flanges as PN 10; ASME Class 150 lap joint up to 12 inch; AWWA Class D fixed flange for 48 to 90 inch. Declare the communication type, HART or PROFIBUS, and the supply voltage. Then send the complete code with your RFQ.

Installation guidance for 50L

Fit the sensor with the pipe full, support the line near the flanges, and observe the grounding instructions. The measuring tube is stainless steel, and the carbon steel lap-joint flanges are hot-dip galvanized, which makes handling safer in the field. Ambient temperature for the transmitter is minus 20 to plus 60 degC as standard.

Servicing 50L

Check flange bolts and the galvanizing on carbon steel parts. Confirm the grounding path periodically, in particular if the pipe is plastic.

The sensor has no wear parts, and the modular transmitter can be replaced without disturbing the pipe, provided the calibration data and nameplate are preserved. Keep a record of the liner type, as the temperature limits differ widely between PTFE (90 degC), hard rubber (80 degC) and polyurethane (50 degC).

On the electrical side, the 50L shares the Proline 50 design: the current output is active or passive, galvanically isolated, with a selectable time constant of 0.01 to 100 seconds and a full scale value that can be set by the user. A status input accepts 3 to 30 V DC and can reset totalizers or suppress measured values, and the pulse output can be scaled for remote counters. For projects with long cable runs, PROFIBUS PA allows several meters on one segment, which saves cabling in a pumping station. Engineers who move from the earlier Promag 10L will find the same sensor idea but a considerably richer set of output functions, and spare-parts buyers should always quote both the root and the nameplate order code.

Quick answers on 50L

Accuracy is stated as 0.5 percent of reading plus 1 mm per second on the pulse output, optionally 0.2 percent of reading plus 2 mm per second. The current output adds typically 5 microampere. Minimum conductivity is 5 microsiemens per cm, or 20 for demineralized water. The supply accepts 85 to 250 V AC, 20 to 55 V AC and 16 to 62 V DC.

Documents and quotation

Technical Information TI00097D is the datasheet for the 50L. Send an RFQ to Seven Star LLC with part number 50L, nominal diameter, liner, flange standard, communication and quantity.

Documentation and Compliance

Industrial buyers often need more than the hardware. When you order the Endress+Hauser 50L, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Endress+Hauser (E & H) ultrasonic flowmeters items can be checked against the bill of materials quickly.

Ordering Checklist for the Endress+Hauser 50L

Before you ask for a quotation for the Endress+Hauser 50L, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the ultrasonic flowmeters already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.

Other Models in the Promag 50 Range

Seven Star LLC supplies models from the Promag 50 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser 50W Promag 50W Water Electromagnetic FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 50L Promag 50L Lap-Joint Electromagnetic FlowmeterUltrasonic FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser 50L Promag 50L Lap-Joint Electromagnetic Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser 50L Promag 50L Lap-Joint

Answers from our engineering team on installation, compatibility and integration.

01What makes the 50L special?
It has a weight-optimized sensor, up to 30 percent lighter, with lap-joint flanges below DN 350 and a modular Proline 50 transmitter.
02What size range does the 50L cover?
DN 25 to 2400 (1 to 90 inch), with PTFE, polyurethane or hard rubber linings depending on size.
03Which communication does the 50L offer?
HART and PROFIBUS PA or DP, as listed on the cover page of TI00097D.
04What conductivity does the 50L require?
At least 5 microsiemens per cm, and at least 20 microsiemens per cm for demineralized water.
05How do I quote the 50L?
Send an RFQ to Seven Star LLC with 50L, nominal diameter, liner, flange standard, communication and quantity.