- Automation & ControlView all 2,859 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser 8F1B Promass F 100 Premium Coriolis Meter
Description
Promass F 100 8F1B: premium accuracy in an ultra-compact package
The Endress+Hauser 8F1B is the entry to the premium end of the Promass range. Described in technical information TI01034D as the flowmeter with premium accuracy, robustness and an ultra-compact transmitter, the Proline Promass F 100 covers an unusually wide nominal diameter span, DN 8 to 250 (3/8 to 10 inch). The headline figure is a mass flow measurement error of plus or minus 0.05 percent with the PremiumCal option, and 0.10 percent in standard form.
In practice that means one platform serves everything from a 2,000 kg/h chemical feed to a 2,200,000 kg/h export line. The sensor housing carries a nominal pressure of up to 40 bar, and the ultra-compact transmitter keeps its IP69 rating as an option. Operators who need premium Coriolis accuracy but have a simple control interface will find the 100 series suits them well.
Why engineers specify the 8F1B
- PremiumCal calibration option for mass flow, plus or minus 0.05 percent of reading
- Standard liquid accuracy 0.10 percent of reading and gas accuracy 0.25 percent of reading
- Nominal diameter DN 8 to 250 in one product family, with 40 bar sensor housing nominal pressure
- Standard medium temperature minus 50 to plus 150 °C, extended version to plus 240 °C by sensor option
- Tube materials include stainless steel 1.4539 (904L) and 1.4404
- IP66/67 standard, IP69 with sensor option CM
- Local display, web server and Heartbeat Technology
8F1B parameters, from the Promass F 100 datasheet
The table lists the principal numbers that the technical information gives for the 8F1B. Process connections, hygienic approvals and pressure derating by temperature are in the document itself.
| Parameter | Value for 8F1B |
|---|---|
| Product root | 8F1B, Proline Promass F 100 |
| Nominal diameter | DN 8 to 250 (3/8 to 10 inch) |
| Full scale, DN 8 / 15 / 25 | 2,000 / 6,500 / 18,000 kg/h |
| Full scale, DN 40 / 50 / 80 | 45,000 / 70,000 / 180,000 kg/h |
| Full scale, DN 100 / 150 / 250 | 350,000 / 800,000 / 2,200,000 kg/h |
| Mass flow accuracy | 0.10 percent standard; 0.05 percent with PremiumCal |
| Gas mass flow accuracy | 0.25 percent of reading |
| Medium temperature, standard | Minus 50 to plus 150 °C |
| Medium temperature, extended | Minus 50 to plus 240 °C (minus 58 to plus 464 °F) |
| Sensor housing pressure | Nominal pressure up to 40 bar (580 psi) |
| Weight DN 8 / 25 / 80 | 9 kg / 12 kg / 53 kg |
| Weight DN 100 / 150 / 250 | 94 kg / 152 kg / 398 kg |
| Ambient temperature | Minus 40 to plus 60 °C |
| Protection | IP66/67 Type 4X; IP69 with option CM |
| Supply voltage | DC 20 to 30 V for HART, PROFIBUS DP, EtherNet/IP |
Applications where 8F1B accuracy pays back
Premium accuracy matters most where the fluid is valuable or where a mass balance is audited. For the 8F1B that includes LPG and condensate transfer, additive injection at refineries, polymer and monomer feeds, and fuel allocation at power plants. Gas users in the GCC apply the 0.25 percent gas figure for compressed air, nitrogen and fuel gas branch lines where an orifice plate was formerly the norm.
The extended temperature version to 240 °C opens up hot oil, heat-transfer fluid and bitumen-adjacent duties. Cryogenic liquids are not claimed for the 100-series text; see the F 300 for minus 196 °C options.
How 8F1B differs from other Promass F variants
Promass F 100, 200 and 300 share the sensor family but differ in electronics. The 8F1B has an ultra-compact transmitter with DC 20 to 30 V supply, limited I/O and a web server. The F 200 (8F2B) offers loop power and fieldbus, DN 8 to 80 only and 0.10 percent liquid accuracy. The F 300 (8F3B) adds up to three I/Os, WLAN display, a 10 W AC or DC supply and a cover-page temperature range down to minus 196 °C.
Numerically: 8F1B reaches 0.05 percent with PremiumCal, 150 or 240 °C by version and DN 250; the F 200 stops at DN 80 and 205 °C; the F 300 reaches 350 °C. Pick the 8F1B when the control system needs a simple HART or fieldbus connection and the size range is wide.
Choosing an 8F1B variant
Start from flow and pressure drop: DN 100 and larger require checking the pressure-loss diagrams in the document. Then choose the calibration: PremiumCal when the measurement feeds custody-adjacent or contractual balances, standard otherwise. Verify that the sensor housing pressure rating covers the rupture risk of your process and consider the rupture disk option if the line carries hazardous media.
Ordering information is long, so give us the full code. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Our team will check it against the technical information before we confirm availability.
Installing the 8F1B and keeping it in service
Mount the 8F1B in a line that stays full and that is free of significant vibration; there is no inlet or outlet run requirement. For heavy sizes, support the pipe on both sides: DN 250 weighs 398 kg with PN 40 flanges, and the sensor must not carry piping loads.
For maintenance, use Heartbeat Technology verification at planned intervals and keep cable glands tight. The web server allows configuration and diagnostics through a laptop; the optional display removes the need for a handheld on most sites.
8F1B frequently asked questions
What does PremiumCal offer on the 8F1B? It gives a mass flow measurement error of plus or minus 0.05 percent of reading, according to the technical information.
What is the size range of the 8F1B? DN 8 to DN 250, equal to 3/8 to 10 inch.
How hot can the medium be? Standard versions work from minus 50 to plus 150 °C; extended temperature versions reach plus 240 °C.
Is the 8F1B washdown resistant? IP66/67 is standard and IP69 can be ordered with sensor option CM.
How do I order the 8F1B? Send an RFQ to Seven Star LLC with 8F1B, nominal diameter, calibration option, output type and quantity.
Documents and quotation
Download the attached technical information TI01034D for the full table of dimensions, pressure-temperature curves and ordering code of the 8F1B.
Include part number 8F1B and the quantity in the RFQ, with the nominal size and your delivery destination, and we will reply in writing.
Datasheets & Documents
- Datasheet Endress+Hauser 8F1B Promass F 100 Premium Coriolis Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser 8F1B Promass F 100 Premium Coriolis
Answers from our engineering team on installation, compatibility and integration.
01What does PremiumCal offer on the 8F1B?
It gives a mass flow measurement error of plus or minus 0.05 percent of reading, according to the technical information.
02What is the size range of the 8F1B?
DN 8 to DN 250, equal to 3/8 to 10 inch.
03How hot can the medium be?
Standard versions work from minus 50 to plus 150 °C; extended temperature versions reach plus 240 °C.
04Is the 8F1B washdown resistant?
IP66/67 is standard and IP69 can be ordered with sensor option CM.
05How do I order the 8F1B?
Send an RFQ to Seven Star LLC with 8F1B, nominal diameter, calibration option, output type and quantity.


















Reviews
There are no reviews yet.