VEGA VEGAFLEX 86: guided radar for extreme process conditions

Where the VEGAFLEX 81 stops at 40 bar, the VEGA VEGAFLEX 86 carries on. The data sheet states pressure from -1 to +400 bar and a process temperature range of -196 to +450 °C, and the device measures level and interface of both liquids and bulk solids. The listing covers the two-wire 4 to 20 mA/HART version with coax probe, which reaches 6 m (19.69 ft) with 2 mm accuracy. Process fittings are threads from G1½ or 1½ NPT and flanges from DN 50 (2 in).

Probe versions and temperature classes

The coaxial version exists in two temperature classes: -196 to +280 °C and -196 to +450 °C, as shown in the dimension drawing of the sheet. Wetted parts are stainless steel, and the instrument seal is made of FFKM or graphite. A special reference probe is available for saturated steam, where it ensures density-independent measurement. The other numbers are consistent with the heavy-duty intent: the dimension drawing carries callouts of 57 mm, 35 mm, 237 mm (9.33 in) and 312 mm (12.28 in) for the threaded and coaxial designs, which helps when checking space above a nozzle or flange. The two-wire loop is powered from 9.6 to 35 V DC and the instrument is also available in a four-wire HART version as well as Profibus PA and Foundation Fieldbus.

VEGAFLEX 86 technical specifications

Values refer to the two-wire 4 to 20 mA/HART coax probe specification sheet.

Parameter Value (datasheet)
Model VEGAFLEX 86, TDR guided wave radar, 4 to 20 mA/HART two-wire, coax probe
Measuring range (coax probe) Up to 6 m (19.69 ft)
Measuring accuracy 2 mm
Process fitting Thread from G1 1/2, 1 1/2 NPT; flanges from DN 50, 2 in
Process pressure -1 to +400 bar (-100 to +40000 kPa / -14.5 to +5800 psig)
Process temperature -196 to +450 C (-320 to +842 F); coax versions -196 to +280 C and -196 to +450 C
Ambient, storage, transport temperature -40 to +80 C
Operating voltage 9.6 to 35 V DC
Wetted materials Stainless steel
Process seal FFKM or graphite
Housing Single or double chamber; plastic, stainless steel or aluminium; up to IP 68 (1 bar)
Electronics HART two-wire, HART four-wire, Profibus PA, Foundation Fieldbus
Measurement Level and interface of liquids and bulk solids
Datasheet reference 42319-EN-151204

Use cases: high-pressure separators, boilers and cryogenic vessels

In Gulf region gas plants, high-pressure separators and scrubbers, steam drums, condensate pots and cryogenic LNG or ethylene vessels are the natural fit. In power stations the guided radar is used on boiler feedwater heaters and drums. In refineries, bypass chambers and standpipes with the coax probe offer reliable level and interface readings regardless of foam, buildup or condensation.

How VEGAFLEX 86 differs from VEGAFLEX 81

  • Pressure: 400 bar versus 40 bar.
  • Temperature: -196 to +450 °C versus -40 to +200 °C.
  • Fittings: G1½ and DN 50 start versus G¾ and DN 25.
  • Medium: liquids and bulk solids versus liquids only.
  • Seal: FFKM or graphite versus FKM, FFKM or EPDM.

Commissioning VEGAFLEX 86

With a supply of 9.6 to 35 V DC and ambient -40 to +80 °C, the sensor is set up through PLICSCOM guided adjustment or PACTware with DTM; HART communicators with AMS or PDM also work. Double chamber housings and IP 68 (1 bar) construction are available. ATEX and IEC approvals are named, and the safety documentation should be requested for the exact type.

Maintenance, spares and ordering

The unit is intended for minimal maintenance. Record the probe length and the dielectric constant assumptions when ordering spares. Enquiries should include flange class, probe type and length, temperature class and electronics. At pressures near the upper limit the flange rating and gasket become the controlling factors, so state the pressure class of the mating nozzle in addition to the process data. In cryogenic duty, tell us the minimum temperature and whether thermal cycling is expected, as the probe and seal must tolerate it. For saturated steam, mention that the reference probe is required so that the density-independent version is quoted. Where the vessel carries both gas and liquid phases at high pressure, the probe seal is the barrier between process and environment, so state any requirement for a secondary seal or gas-tight feedthrough when asking for a quotation. Interface measurement between two liquids requires data on the dielectric constants, and a bulk solids application needs the grain size and the expected pulling or tensile force on the probe.

VEGAFLEX 86 FAQ summary

  • How much pressure can the VEGAFLEX 86 take? The specification sheet gives -1 to +400 bar (up to 5800 psig).
  • What is the temperature range of the VEGAFLEX 86? -196 to +450 C; the coax versions are shown in -196 to +280 C and -196 to +450 C classes.
  • Does the VEGAFLEX 86 handle saturated steam? VEGA states a special reference probe ensures density-independent measurement in saturated steam applications.
  • Can the VEGAFLEX 86 measure solids? Yes, the sheet describes level and interface measurement of liquids and bulk solids.
  • Which seal materials are used in the VEGAFLEX 86? FFKM or graphite, with stainless steel wetted parts.

Documents and quotation

The manufacturer VEGA VEGAFLEX 86 datasheet is available as a PDF download on this page, so your engineers can check ranges, materials and dimensions against the data sheet before ordering. To request a quotation send the part number VEGAFLEX 86 together with the quantity, the required process connection, electronics version and any approval requirement through the RFQ form or by email. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; product names and marks belong to their owners.

What to Include in Your VEGA VEGAFLEX 86 Enquiry

An accurate quotation for the VEGA VEGAFLEX 86 depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing radar & guided wave radar level and reply with availability and a realistic delivery estimate.

Datasheets & Documents
  • PDF Datasheet VEGA VEGAFLEX 86 Guided Wave Radar 400 bar 450 C Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

VEGA is a German maker of level and pressure instruments. Bruno Grieshaber founded the company in 1959 in Triberg in the Black Forest, and it has been based in Schiltach since 1975, still family owned as VEGA Grieshaber KG. VEGA is best known for radar level sensors: it introduced the first two-wire radar level sensor in 1997 and the first 80 GHz radar sensor for bulk solids, the VEGAPULS 69, in 2015.

Seven Star LLC is an independent supplier listing VEGA radar and guided wave radar transmitters, point level switches, pressure transmitters and signal conditioning instruments for buyers in Oman and the GCC. Sensors are matched from the product code on the type label.

VEGA at a glance

Origin Founded by Bruno Grieshaber in 1959 in Triberg, Germany
Headquarters Schiltach, Black Forest, Germany (since 1975)
Ownership Family-owned company: VEGA Grieshaber KG
Milestones First two-wire radar level sensor (1997), first 80 GHz radar for bulk solids, VEGAPULS 69 (2015), VEGAPULS 6X single radar platform for liquids and solids
Product families VEGAPULS radar, VEGAFLEX guided wave radar, VEGASWING and VEGAPOINT switches, VEGACAL capacitive probes, VEGABAR and VEGADIF pressure, VEGAMET and VEGADIS signal conditioning

VEGA sensor and instrument series

Series Type Typical use
VEGAPULS 6X, VEGAPULS 69, VEGAPULS 64 Process radar level transmitters (80 GHz) Storage and process tanks, reactors with agitators, silos and bulk solids
VEGAPULS 11, 21, 31, 42 Compact radar sensors Water and wastewater, simple storage tanks; VEGAPULS 42 with IO-Link for machine integration
VEGAPULS C 21, C 11, C 22, C 23 Radar sensors with fixed cable, IP68 Wet wells, pumping stations, open channels and river levels
VEGAFLEX 81, 82, 83, 86 Guided wave radar (TDR) Level and interface in liquids, bulk solids, hygienic and high-temperature or high-pressure service (VEGAFLEX 86)
VEGASWING 61, 63, VEGAPOINT 21 Vibrating and capacitive point level switches Overfill protection, dry-run protection and high or low level alarms
VEGACAL 62 to VEGACAL 67 Capacitive rod and cable probes Point and continuous level in solids and conductive or adhesive liquids
VEGABAR 82, 83, 28, 29, 38 Pressure transmitters, ceramic or metallic cell Process pressure and hydrostatic level; compact 18/19 and 28/29/38 versions for utilities
VEGADIF 85 Differential pressure transmitter DP flow, filter monitoring and level in pressurised vessels
VEGAMET 841, VEGADIS 176 Controller and loop display Level display, pump control and remote indication of 4-20 mA signals

Where VEGA instruments are used

VEGA radar sensors measure level in crude oil and product tanks, separators, chemical reactors, cement and aggregate silos, grain stores and water reservoirs. Compact cable radars are widely used in wastewater pumping stations and flood monitoring. Because 80 GHz radar focuses a narrow beam, it can measure past internal structures in a tank, and it is not affected by the temperature, pressure or vapour above the product, which suits hot Gulf storage tanks.

Ordering VEGA instruments: what we need

The product code on the type label (for example PS64.XXXXXXX) fixes the measuring range, antenna or probe, process connection, electronics and approvals. Send it with the serial number. For a new measurement add the medium and its dielectric constant if known, tank or silo height and internals, process pressure and temperature, process connection, output (4-20 mA HART, PROFIBUS PA, Modbus or IO-Link), and any hazardous-area or overfill protection approval required.

Facts checked against VEGA company and product information, October 2026.

FAQ

Questions about the VEGA VEGAFLEX 86 Guided Wave Radar 400 bar 450 C

Answers from our engineering team on installation, compatibility and integration.

01How much pressure can the VEGAFLEX 86 take?
The specification sheet gives -1 to +400 bar (up to 5800 psig).
02What is the temperature range of the VEGAFLEX 86?
-196 to +450 C; the coax versions are shown in -196 to +280 C and -196 to +450 C classes.
03Does the VEGAFLEX 86 handle saturated steam?
VEGA states a special reference probe ensures density-independent measurement in saturated steam applications.
04Can the VEGAFLEX 86 measure solids?
Yes, the sheet describes level and interface measurement of liquids and bulk solids.
05Which seal materials are used in the VEGAFLEX 86?
FFKM or graphite, with stainless steel wetted parts.