Brand: ABB
ABB 1SBL237001R1311 AF26-30-11-13 Contactor 11 kW, 1 N.O. + 1 N.C.
Description
ABB 1SBL237001R1311: AF26 motor contactor with fixed auxiliary block
ABB 1SBL237001R1311 is the AF26-30-11-13, a three-pole motor contactor for 26 A AC-3 duty that already includes a 1 N.O. plus 1 N.C. auxiliary contact block. The datasheet calls this a 2-stack contactor, meaning an auxiliary block is mounted on the main body and cannot be removed. Those auxiliary contacts are mechanically linked in line with Annex L of IEC 60947-5-1 and the N.C. contacts are mirror contacts per Annex F of IEC 60947-4-1, which is valuable for safety-related feedback circuits.
The contactor controls power circuits up to 690 V AC and 220 V DC. AC-3 power ratings are 11 kW at 380-415 V, 15 kW at 440-690 V and 6.5 kW at 220-240 V. The coil is the 100-250 V AC/DC type.
Highlights
- 26 A AC-3 up to 440 V, 23 A at 500 V and 17 A at 690 V.
- Fixed auxiliary block 1 N.O. + 1 N.C., mechanically linked.
- AC-8a rating 30 A, 15 kW at 400 V, ambient up to 40 degrees C.
- NEMA size 1 with 27 A thermal current; UL 3-phase motor rating 7.5 hp at 200-240 V and 15 hp at 440-480 V.
- Weight 0.350 kg.
1SBL237001R1311 data table
| Order code | 1SBL237001R1311 |
|---|---|
| Type | AF26-30-11-13 |
| Main poles | 3 N.O. |
| Built-in auxiliary contacts | 1 N.O. + 1 N.C. (fixed, mechanically linked) |
| Coil | 100-250 V 50/60 Hz and DC |
| AC-3 current, 220-440 V | 26 A |
| AC-3 current 500 V / 690 V | 23 A / 17 A |
| AC-3 power 400 V / 440 V | 11 kW / 15 kW |
| AC-1 at 40 / 60 / 70 C | 45 A / 40 A / 32 A |
| Ith (10 mm2) | 50 A |
| AC-8a current, 400 V | 30 A (15 kW) |
| gG fuse up to 500 V | 50 A |
| Icw 1 s | 700 A |
| Maximum breaking capacity at 440 V / 690 V | 500 A / 200 A |
| Power loss per pole AC-1 / AC-3 | 1.8 W / 0.6 W |
| Auxiliary AC-15 at 230 V / 400 V | 4 A / 3 A |
| NEMA size | 1 (27 A) |
| Main terminals / torque | M4 / 2.5 Nm |
| Stripping length main | 14 mm |
| Weight | 0.350 kg |
Where AF26-30-11-13 differs from other AF26 contactors
The basic AF26-30-00 has no auxiliary contacts at all. This 11 version has two, built in, and is the one to choose when a starter needs both a hold-in or signalling contact and an N.C. interlock. At the same AC-3 current of 26 A the AF26-30-11 gives 11 kW at 400 V, whereas the AF38-30-00 manages 38 A and 18.5 kW. Weight rises from 0.310 kg for the plain AF26 to 0.350 kg because of the auxiliary block.
Use in motor feeders
With 11 kW at 400 V, the contactor starts pumps, ventilation units and conveyor drives common in Omani processing plants. The mirror N.C. contact feeds back to a safety PLC that the main poles have opened, supporting contactor monitoring in a stop circuit; the linked N.O. contact reports the closed state. Because the auxiliary contacts are factory fitted, panel builders save time and mounting space.
Planning and compatibility
The datasheet also lists pilot-duty ratings for the auxiliary circuit, A600 and Q600, with a 10 A thermal AC rating and 7200 VA making and 720 VA breaking capacity, and 2.5 A on DC. In the IEC rating, the auxiliary contacts withstand 100 A for 1 s, switch from a 12 V and 3 mA minimum, and have a non-overlap time of at least 2 ms between N.O. and N.C. contacts. These numbers are the useful ones when the feedback goes to a PLC or safety relay input.
Observe that the thermal overload relay is chosen separately and that ambient limits become -25 to +60 degrees C when a relay is fitted. The accessory table for this 3-pole contactor allows a limited count of additional N.C. blocks, a maximum of four N.C. contacts in total in the preferred positions and three in the tilted positions. Fixed short-circuit protection for contactors used without an overload relay is 50 A gG up to 500 V AC (a 150 A type NTD fuse for the 600 V UL case).
Installation
Fit on 35 mm DIN rail or by two diagonal M4 screws. Torque main terminals to 2.5 Nm, coil and auxiliary terminals to 1.2 Nm. Use conductors of 2.5 to 10 mm2 on the poles, 1 to 2.5 mm2 on the auxiliary circuit, and strip 14 mm and 10 mm respectively.
Care
Test the mechanically linked contacts at each service by checking the N.O. and N.C. contacts never show closed together. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about 1SBL237001R1311
What motor rating applies to 1SBL237001R1311? 26 A AC-3 at 380-440 V, which corresponds to 11 kW at 400 V and 15 kW at 440 V.
What auxiliary contacts does 1SBL237001R1311 include? One normally open and one normally closed contact, built in and mechanically linked.
Are the auxiliary contacts of 1SBL237001R1311 removable? No. The datasheet describes the auxiliary block of this 2-stack type as non-removable.
What is the coil range of 1SBL237001R1311? 100-250 V at 50/60 Hz and also 100-250 V DC.
What UL/NEMA data is given for 1SBL237001R1311? NEMA size 1 with 27 A and UL 3-phase motor ratings such as 7.5 hp at 200-240 V and 15 hp at 440-480 V.
Documents and quotation
Download the ABB technical datasheet for 1SBL237001R1311 from this page. Send an RFQ with part number 1SBL237001R1311, the quantity and the delivery destination to receive a quotation.
Selection Notes for the ABB 1SBL237001R1311
When comparing the ABB 1SBL237001R1311 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the ABB contactors & overload relays range and confirm the correct order code before you commit.
Documentation and Compliance
Industrial buyers often need more than the hardware. When you order the ABB 1SBL237001R1311, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that ABB contactors & overload relays items can be checked against the bill of materials quickly.
Datasheets & Documents
- Datasheet ABB 1SBL237001R1311 AF26-30-11-13 Contactor 11 kW, 1 N.O. + 1 N.C. Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB 1SBL237001R1311 AF26-30-11-13 Contactor 11 kW,
Answers from our engineering team on installation, compatibility and integration.
01What motor rating applies to 1SBL237001R1311?
26 A AC-3 at 380-440 V, which corresponds to 11 kW at 400 V and 15 kW at 440 V.
02What auxiliary contacts does 1SBL237001R1311 include?
One normally open and one normally closed contact, built in and mechanically linked.
03Are the auxiliary contacts of 1SBL237001R1311 removable?
No. The datasheet describes the auxiliary block of this 2-stack type as non-removable.
04What is the coil range of 1SBL237001R1311?
100-250 V at 50/60 Hz and also 100-250 V DC.
05What UL/NEMA data is given for 1SBL237001R1311?
NEMA size 1 with 27 A and UL 3-phase motor ratings such as 7.5 hp at 200-240 V and 15 hp at 440-480 V.