Moore Industries THZ/PRG/4-20MA/12-42DC [HPP] Head Transmitter

Description

Moore Industries THZ/PRG/4-20MA/12-42DC [HPP]: Smart HART in a hockey puck

Moore Industries THZ/PRG/4-20MA/12-42DC [HPP] is the smallest way to buy THZ performance. The electronics are potted into a round, encapsulated hockey-puck module that sits inside a DIN-type connection head directly on the thermowell. The measuring signal never travels a long way as a millivolt level; it is digitised at the head and sent as a 4-20 mA loop with HART data.

This code deliberately leaves the head out: the housing bracket shows only HPP, so the unit is an electronics-only purchase that you fit into a head you already own, or one that arrives with a complete temperature assembly. For plant engineers it is an efficient replacement when a transmitter in an existing head fails.

Main benefits of THZ/PRG/4-20MA/12-42DC [HPP]

  • 101 g weight and a compact round form that fits standard connection heads.
  • 1000 Vrms isolation between input and output, higher than the DIN version.
  • Programmable by HART communicator, HART system or PC through the usual interface cable.
  • Sensor diagnostics and a trim function that tracks the actual sensor curve between two calibration points.
  • Temperature compensation of the reference junction and an ambient effect small enough for outdoor heads.

Because the module has no display, the loop current and the HART data are the only outputs; if you need a local readout, step up to the DH or TDZ versions.

THZ/PRG/4-20MA/12-42DC [HPP] data table

The values below are those that distinguish the hockey-puck module in the THZ datasheet.

Parameter Value for THZ/PRG/4-20MA/12-42DC [HPP]
Model code THZ/PRG/4-20MA/12-42DC [HPP]
Housing HPP: encapsulated hockey-puck module for mounting inside a sensor connection head
Input Programmable (PRG): RTD 2-, 3-, 4-wire Pt, Cu, Ni; thermocouple J, K, E, T, R, S, B, N, C; 0 to 4000 ohm; -50 to 1000 mV; potentiometer
Output 4-20 mA scalable with HART superimposed
Supply 12-42 V DC
Isolation 1000 Vrms input to output continuous
Weight 101 g (3.6 oz) for the HPP module
Step response 600 ms maximum
RFI/EMI immunity 10 V/m at 80-1000 MHz, 1 kHz AM, 0.5% of span or less error (HPP, LH and CH6 mounting)
Stability, T/C or mV, input to HART 0.0084% of span in 1 year, 0.0145% in 3 years, 0.019% in 5 years
Digital accuracy Plus or minus 0.1 C with Pt RTDs
Analog output accuracy Plus or minus 0.015% of span
Resolution Input 20-bit, output 16-bit
Ambient -40 to +85 C, up to 95% RH non-condensing
Head options (order code) LH1NS, LH1MS, LH1CS polyester IP66 heads; LH2NS, LH2MS explosion-proof heads; CH6 polypropylene connector head
Heavier alternatives LH1 assembly 434 g; LH2 assembly 654 g

How THZ/PRG/4-20MA/12-42DC [HPP] differs from other THZ variants

Weight tells the story: 101 g for the HPP against 221 g for the DIN module and 1.75 kg for the DH enclosure. The HPP offers the highest isolation, 1000 Vrms, where the DIN and DH versions are rated at 500 Vrms. Radio frequency immunity is lower, 10 V/m rather than the 30 V/m of DIN and DH.

The long-term stability for thermocouple and millivolt inputs is identical to the DIN version, but the HART-to-output portion of the budget is smaller for the HPP (0.0578% over one year compared with 0.08% for DIN).

Typical use of THZ/PRG/4-20MA/12-42DC [HPP]

Typical points are reactor jackets, steam lines and packaged skids where space around the sensor is tight. Mounted in an aluminum or polyester head directly on a thermowell, the module is suited to heat exchanger inlets and outlets in refineries, and to boiler flue and feedwater lines in power stations.

Marine and offshore users in the Gulf value the compact form because several sensor points fit on a single skid with minimal cable runs, and the transmitter sits right at the sensor.

Selecting heads and sensors for THZ/PRG/4-20MA/12-42DC [HPP]

The datasheet lists polyester LH1 heads (NEMA 4X, IP66), explosion-proof LH2 heads, and the CH6 polypropylene connector head. For an LH2 head, the E suffix marks an ATEX flameproof enclosure, and the P suffix supplies a pipe-mount kit. Select the head by the area classification and cable gland thread: N for NPT, M for metric M20 cable, C for G1/2 process.

Use a four-wire Pt100 or Pt1000 element where possible. Lead resistance for three-wire hookups should stay below 35 ohms per leg.

Mounting THZ/PRG/4-20MA/12-42DC [HPP] in the head

Seat the module in the head following the head instructions, connect the RTD or thermocouple leads to terminals 1 to 4, then wire the loop to the PS terminals. Test the loop with a HART communicator and set the range. In an explosion-proof head, secure the cover completely and verify the gland sealing.

Allow the unit to warm up for eight seconds before expecting specified accuracy. Record the sensor serial and trim data in the commissioning sheet.

Service of THZ/PRG/4-20MA/12-42DC [HPP]

There is no routine service beyond the head: check for water ingress, clean terminals and verify that the sensor remains within calibration. If the output ever goes to the fail-safe value, examine the sensor first; the diagnostics identify an open or shorted element.

Replacement is a quick swap of the module; use the saved configuration file to restore the previous settings in a minute.

Enquiry details for THZ/PRG/4-20MA/12-42DC [HPP]

Please send the complete string THZ/PRG/4-20MA/12-42DC [HPP] with your enquiry together with the head type, so we can confirm the combination.

Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.

Documents and quotation

We can attach the datasheet for Moore Industries THZ/PRG/4-20MA/12-42DC [HPP] to our quotation. Submit an RFQ listing the part number, quantity and destination to receive our response.

Other Models in the THZ TDZ Range

Seven Star LLC supplies models from the THZ TDZ range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Moore Industries TDZ/PRG/4-20MA/12-42DC [BH2NGE] TransmitterTemperature TransmittersView details
Moore Industries THZ/PRG/4-20MA/12-42DC [HPP] Head TransmitterTemperature TransmittersYou are viewing this model
Moore Industries THZ/PRG/4-20MA/12-42DC [WL2NG] WirelessHART CaseTemperature TransmittersView details
Moore Industries THZ/PRG/4-20MA/12-30DC/-ISF [DH2NGP] TransmitterTemperature TransmittersView details
Moore Industries THZ/PRG/4-20MA/12-42DC [DIN] Rail TransmitterTemperature TransmittersView details
Datasheets & Documents
  • PDF Datasheet Moore Industries THZ/PRG/4-20MA/12-42DC [HPP] Head Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the Moore Industries THZ/PRG/4-20MA/12-42DC [HPP] Head

Answers from our engineering team on installation, compatibility and integration.

01Does the HPP module include a connection head?
No. The HPP code is the encapsulated module only; heads such as LH1NS or LH2NS are ordered through a separate housing code or a complete assembly.
02How much isolation does the HPP provide?
1000 Vrms input to output continuous, compared with 500 Vrms for the DIN and DH versions.
03What is the module weight?
The HPP module weighs 101 g (3.6 oz), well below the 221 g DIN version.
04What RFI immunity applies?
The datasheet states 10 V/m at 80-1000 MHz with 0.5% of span or less error for HPP, LH and CH6 mounting.
05Is there a local display?
No. The hockey-puck module relies on the 4-20 mA loop and HART data; displays are available in the DH enclosure and on TDZ units.