Brand: Yokogawa
Yokogawa DY050 digitalYEWFLO 2-inch Vortex Flowmeter
Description
Yokogawa DY050 overview
The Yokogawa DY050 is the 50 mm (2 inch) size of the Yokogawa digitalYEWFLO vortex flowmeter series. A vortex flowmeter measures volumetric flow by sensing the vortices shed alternately from a bluff body (the shedder bar) in the pipe, and the digitalYEWFLO adds Spectral Signal Processing (SSP), a Yokogawa digital signal technology, to keep readings stable in low flow, vibration and pulsating-flow conditions.
The model name Yokogawa DY050 is the size block of the order code. It is followed by suffix blocks for output signal and communication (for example -D for BRAIN, -E for HART or -J for HART 5/HART 7), body material (A for SCS14A, B for CF8M), shedder bar material, process connection (wafer or flange, JIS, ANSI or DIN ratings), electrical connection and indicator, and optional codes such as /MV for the built-in temperature sensor. Because the DY050 name is shared by many configurations, the full code must be checked against the application data before purchase.
This page describes the DY050 as published in the manufacturer’s general specification GS 01F06A00, written in our own words for buyers who need to identify the exact part. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We supply against the part number you provide and do not substitute without your written agreement.
Key features of the DY050
- Spectral Signal Processing technology analyses the fluid condition and selects optimum adjustments automatically, giving stable measurement at low flow.
- Self-diagnostics that indicate application conditions such as pipe vibration and pulsating flow.
- Accuracy of plus or minus 0.75 percent of reading for liquids and plus or minus 1 percent of reading for gas and steam; repeatability plus or minus 0.2 percent of reading.
- No-moving-parts stainless steel detector; wide process temperature range, up to 450 degC with the high-temperature version and minus 196 degC with the cryogenic version.
- Dual output: 4 to 20 mA DC (two-wire) and a pulse, alarm or status transistor output (three-wire open collector), selected by parameter.
- Optional multi-variable type (/MV) with a built-in Pt1000 temperature sensor in the shedder bar and mass flow calculation using a built-in steam table (IAPWS-IF97).
- Reduced bore options (/R1, /R2) and explosion-protected versions, with enclosure rating IP66/IP67 and Type 4X.
DY050 technical specifications
| Item | Specification |
|---|---|
| Model | DY050, digitalYEWFLO vortex flowmeter, size 50 mm (2 inch) |
| Fluids | Liquid, gas and steam (avoid multiphase and sticky fluids) |
| Accuracy | Plus or minus 0.75 percent of reading (liquid); plus or minus 1 percent of reading (gas, steam) |
| Repeatability | Plus or minus 0.2 percent of reading |
| Process temperature | Minus 29 to plus 250 degC standard; minus 196 to plus 100 degC cryogenic; minus 29 to plus 450 degC high-temperature version |
| Process pressure | Minus 0.1 MPa to the flange rating |
| Output | 4 to 20 mA DC two-wire plus transistor contact output (pulse, alarm, status) |
| Communication | BRAIN, HART (HART 5 or HART 7 with code -J) or FOUNDATION Fieldbus (separate specification) |
| Power supply | 10.5 to 42 V DC (10.5 to 30 V DC with lightning protector) |
| Ambient temperature | Minus 29 to plus 85 degC (integral type); minus 29 to plus 80 degC with indicator |
| Wetted parts | Body SCS14A or CF8M; shedder bar duplex stainless steel; gasket SUS316 with PTFE coating |
| Housing | Aluminum alloy ADC12, polyurethane coating, IP66/IP67 and Type 4X |
| Electrical connection | JIS G1/2 female, 1/2 NPT female or ISO M20 x 1.5 female |
| Signal cable (remote type) | Up to 30 m |
The values above are taken from the manufacturer’s general specification for the digitalYEWFLO vortex flowmeters. Treat the document as the controlling reference and confirm every figure against the latest revision before final design, because the manufacturer may change specifications without notice.
Typical applications in oil and gas, utilities, water and manufacturing
Vortex flowmeters are widely used for steam, compressed air, process gas and clean liquids in oil and gas facilities, refineries, district cooling and utility plants, desalination, food and beverage, and general manufacturing across Oman and the GCC. Steam metering in particular is common in boiler houses and heat-exchange networks where energy accounting matters.
A buyer who already has the DY050 installed usually wants the same suffix code again, which keeps panel cutouts, terminal layouts, spare stocks and documentation unchanged. That is the main reason this exact part number is searched for rather than a generic description.
Selection and compatibility notes for the DY050
- Output code: -D BRAIN, -E HART 5, -J HART 5 or HART 7 (specify which), -F FOUNDATION Fieldbus, -N remote type detector.
- Body material A (SCS14A) pairs with JIS process connections; B (CF8M) pairs with ANSI and DIN connections.
- Process connection codes cover wafer and flange styles (JIS 10K to 40K, ANSI Class 150 to 1500, DIN PN10 to PN40), so match the pipe flange standard.
- For steam mass flow, add /MV; for a lower flow range at the same face-to-face length, consider the reduced bore option /R1 or /R2.
- Straight-run and installation recommendations in the general specification should be checked against the piping layout before ordering.
The remote-type converter DYA and the signal cable DYC are listed as separate models in the same general specification.
Installation and commissioning
Install the meter in a pipe with the straight-run lengths and orientation recommended in the general specification, with the pipe running full and the flange or wafer type matched to the line rating. Avoid mounting close to control valves or pumps, protect the converter from vibration, route cable entries downward, and for steam lines consider the drain and condensate points. On commissioning, set the pipe inner diameter, fluid type, and output ranges, confirm the self-diagnostic status, and compare the reading against a known reference where possible.
Before energising a DY050 in a hazardous or critical service, confirm that the selected variant, enclosure rating and any approvals you require are covered by the order string and by your site rules.
Maintenance and spare parts
The no-moving-parts detector keeps routine maintenance low. Periodically check the diagnostic indications, inspect cable glands and cover seals, verify the electrical connection and loop supply, and clean or inspect the meter body and shedder bar if the process fluid is dirty or if the diagnostics indicate a change. Record the full order string, serial number and configuration so the instrument can be replaced or reconfigured quickly.
Related products and ordering notes
The DY050 belongs to the digitalYEWFLO vortex flowmeters group. Related family members, modules, software and accessories are listed in the same general specification, and we can quote them together with the DY050 when you need a complete panel or loop. Because many Yokogawa instruments are specified by long suffix strings, always quote the complete order code, the option codes, the quantity and the destination. If your installed unit is an older revision, send a nameplate photograph or the exact code printed on it so that compatibility can be checked before any quotation is issued.
Frequently asked questions about the DY050
- What size is the DY050? The DY050 is the 50 mm (2 inch) size of the digitalYEWFLO series, according to the model and suffix code table in the general specification.
- What accuracy does the DY050 have? The stated accuracy is plus or minus 0.75 percent of reading for liquids and plus or minus 1 percent of reading for gas and steam, with repeatability of plus or minus 0.2 percent of reading.
- Can the DY050 measure steam mass flow? With the multi-variable option /MV, the built-in temperature sensor and steam table (IAPWS-IF97) allow mass flow calculation of saturated and superheated steam.
- Which communication protocols are available? BRAIN with code -D, HART with -E or -J, and FOUNDATION Fieldbus with -F, which is covered by a separate specification.
- What do I send for a DY050 RFQ? Send the full DY050 order string including output code, body material, process connection, indicator and options, the quantity, and the delivery location in Oman or the GCC.
Documents and quotation
The manufacturer’s datasheet for the DY050 is available on this page for download and lists the model and suffix codes, specifications and dimensions in full. To request a quotation, send the RFQ with the part number DY050, the quantity, any option codes and the delivery destination in Oman or the GCC. Our team will confirm availability, lead time and commercial terms for the DY050 by return.
Datasheets & Documents
- Datasheet Yokogawa DY050 digitalYEWFLO 2-inch Vortex Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa DY050 digitalYEWFLO 2-inch Vortex Flowmeter
Answers from our engineering team on installation, compatibility and integration.
01What size is the DY050?
The DY050 is the 50 mm (2 inch) size of the digitalYEWFLO series, according to the model and suffix code table in the general specification.
02What accuracy does the DY050 have?
The stated accuracy is plus or minus 0.75 percent of reading for liquids and plus or minus 1 percent of reading for gas and steam, with repeatability of plus or minus 0.2 percent of reading.
03Can the DY050 measure steam mass flow?
With the multi-variable option /MV, the built-in temperature sensor and steam table (IAPWS-IF97) allow mass flow calculation of saturated and superheated steam.
04Which communication protocols are available?
BRAIN with code -D, HART with -E or -J, and FOUNDATION Fieldbus with -F, which is covered by a separate specification.
05What do I send for a DY050 RFQ?
Send the full DY050 order string including output code, body material, process connection, indicator and options, the quantity, and the delivery location in Oman or the GCC.