Brand:

Keyence FS-N14N Digital Fiber Amplifier Expansion Unit, NPN

Description

Keyence FS-N14N: two-output expansion amplifier and its code explained

The Keyence FS-N14N is an expansion unit in the FS-N digital fiber amplifier series. Unlike the main units that carry the power cable, an expansion unit snaps onto a main unit on the DIN rail and draws power through it, so extra detection points cost less wiring. The FS-N14N is the high-functionality version: it offers two NPN control outputs and one external input. Seven Star LLC supplies the FS-N14N in Oman and the GCC as an independent supplier in Muscat.

Reading the code: FS-N is the series, 14 is the high-function two-output expansion position and N is NPN. The maker lists it as Expansion unit with the type High functionality 2 output, cable connection.

Two outputs let one amplifier serve two decisions at once: for example a window comparator with a low and a high limit, or a presence output plus a separate fault output. The external input can be used for calibration commands from the PLC, such as remote teaching.

FS-N14N technical specifications

Parameter Specification
Manufacturer / part number Keyence / FS-N14N
Product description Fiber Amplifier, Cable Type, Expansion Unit, NPN
Type High functionality 2 output, cable
Output NPN
Main unit / expansion unit Expansion unit
Control output 2 NPN open collector, 24 V; 100 mA or less per output; 20 mA or less when chained; residual voltage 1 V or less
Monitor output (1-5 V) None
External input 1 (input time 2 ms ON / 20 ms OFF or more; 25 ms or more when external calibration is selected)
Light source Red, 4-element LED
APC ON/OFF switchable (factory setting OFF)
Response time 50 µs (HIGH SPEED) / 250 µs (FINE) / 500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA)
Interference prevention units 0 for HIGH SPEED; 4 for FINE; 8 for TURBO, SUPER, ULTRA and MEGA
Unit expansion Up to 16 units in total; a two-output type counts as two units
Power voltage 12 to 24 VDC ±10 %, ripple (P-P) 10 % or less
Current consumption Normal 900 mW or less (36 mA at 24 V, 48 mA at 12 V); Eco ON 800 mW or less; Eco FULL 470 mW or less
Ambient light Incandescent lamp 20,000 lux or less; sunlight 30,000 lux or less
Ambient temperature -20 to +55 °C, no freezing (derated with chained units)
Relative humidity 35 to 85 % RH, no condensation
Vibration / shock 10 to 55 Hz, 1.5 mm double amplitude; 500 m/s2
Case material Polycarbonate
Weight Approx. 70 g

How the FS-N14N works as an expansion unit

An expansion unit shares the supply and interference-management bus of the main unit it is attached to, but it has its own light source and receiving element, so every unit still watches its own fiber. The FS-N14N compares the received light with its thresholds and drives two NPN outputs, so one fiber can feed two switching decisions without needing two amplifiers.

The external input is used to trigger functions from outside, such as sensitivity calibration while a good part is in position. This is helpful where operators cannot reach the amplifier buttons, because the PLC can run the teach cycle at the start of a batch.

Because it counts as two units on the chain for output current purposes, plan the 16-unit limit with this in mind: a bank made only of two-output expansion units will reach the chain limit with fewer physical amplifiers.

Where the FS-N14N fits: main units and siblings

The FS-N14N needs a main unit beside it. Natural companions are FS-N11N (NPN standard), FS-N11MN (monitor output) and FS-N13N (cable-type NPN main unit); with a PNP main unit such as FS-N11P, check that your PLC input card accepts mixed polarity before combining families. FS-N12CP is the M8 connector, PNP expansion unit for plug-in installation.

Install the FS-N14N after the main unit is chosen: it contains no separate power lead, so the first element in the chain is what sets the supply, the temperature derating and the wiring layout.

Selecting FS-N14N: ordering checklist

  • A main unit with matching polarity to sit beside it.
  • Whether two outputs and an external input are really needed; if not, a plain expansion unit is simpler.
  • Output current of each of the two NPN outputs: keep it at 20 mA or less when chained.
  • Fiber type for each channel, which may be different on adjacent amplifiers.
  • Total number of units in the chain and the cabinet ambient temperature.
  • Response time per channel and interference prevention requirements.

Installing, commissioning and maintaining FS-N14N

Snap the FS-N14N onto the side of its main unit on the same DIN rail and slide the lock to secure the pair. Fit fibers fully, then run the tuning routine on each channel with the actual target.

Wire the two NPN outputs to separate PLC inputs and label both clearly, because the two outputs often carry different meaning, for example detect and fault. If you use the external input for calibration, keep the pulse longer than 25 ms as listed in the table.

During maintenance, replace the whole expansion unit rather than repairing it, and take the opportunity to wipe the fiber tips. Record the output assignment of each channel in your panel documentation so a replacement is quick.

Typical applications of FS-N14N in Oman and the GCC

The FS-N14N is useful in Oman and the GCC for machines that check two states with one sensor, for example filling lines that detect a bottle and confirm its cap in the same fiber path, or conveyors that need a window comparator. High ambient temperatures in unconditioned plant rooms make the derating note important.

It is also valuable in retrofit work on existing lines, where adding a second decision point at the same location avoids pulling extra cables.

FS-N series models compared with FS-N14N

The table helps place the FS-N14N among the other FS-N amplifiers.

Model Maker description / difference
FS-N14N Expansion unit, NPN, 2 outputs, external input
FS-N11N Main unit, NPN, standard 1 output
FS-N11MN Main unit, NPN, monitor output
FS-N12CP Expansion unit, PNP, M8 connector
FS-N13N Cable type main unit, NPN

Information to send with your FS-N14N RFQ

  • Exact part number: FS-N14N, with the quantity and any matching items listed below.
  • The main unit it will attach to.
  • How the two outputs and the external input will be used.
  • Fiber unit types for the channel.
  • Total chain length and cabinet temperature.
  • Project reference, delivery location in Oman or the GCC and the lead time you need.

Documents and quotation

Send us the part number FS-N14N and we will confirm the available documents, including the maker datasheet and instruction manual where we can provide them. Prices are quoted per request and are not shown on this page.

Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC. We are not affiliated with the manufacturer, and every quotation states delivery and lead time against your RFQ.

Other Models in the Keyence Fs N Range

Seven Star LLC supplies models from the Keyence Fs N range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Keyence FS-N11N Digital Fiber Amplifier, Main Unit, NPNPhotoelectric SensorsView details
Keyence FS-N12CP Digital Fiber Amplifier, M8 Expansion, PNPPhotoelectric SensorsView details
Keyence FS-N13N Digital Fiber Amplifier, 2-Output, NPNPhotoelectric SensorsView details
Keyence FS-N11P Digital Fiber Amplifier, Main Unit, PNPAutomation AccessoriesView details
Keyence FS-N11MN Digital Fiber Amplifier, Monitor Output, NPNAutomation AccessoriesView details
Keyence FS-N14N Digital Fiber Amplifier Expansion Unit, NPNAutomation AccessoriesYou are viewing this model
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Keyence is a Japanese maker of sensors, measuring instruments and machine vision, founded in 1974 by Takemitsu Takizaki and headquartered in Osaka. It sells directly to factories and makes photoelectric and laser sensors, code readers, vision systems, measurement systems and microscopes.

Seven Star LLC sources and supplies Keyence sensors and code readers for machine builders and maintenance teams in Oman and the GCC.

Keyence company profile

Founded 1974, Japan
Founder Takemitsu Takizaki
Headquarters Osaka, Japan
Sales model Direct sales
Product families LR-Z and LR-W laser and photoelectric sensors, SR-X code readers, IV and CV-X vision systems, LJ-X laser profilers

Keyence series listed

Three series appear on this page. The LR-Z is a self-contained CMOS laser sensor. Keyence describes it as detecting by distance and by received light, with one-button teaching, a stainless steel body rated IP68/69K and a range of up to 500 mm depending on the model; the LR-ZB250CP is the listed type. The LR-W500C is a full-spectrum reflective photoelectric sensor from the LR-W series. The SR-X100 is an autofocus 2D code reader.

Keyence products we list

Family Examples
Photoelectric Sensors LR-W500C Full-Spectrum Reflective Photoe…
Laser Distance, LiDAR & Radar Sensors LR-ZB250CP LR-Z Series Self-Contained CM…
Machine Vision SR-X100 Autofocus 2D Code Reader

Ordering Keyence sensors: what we need

Keyence type codes are short but exact. Send the complete model, such as LR-ZB250CP, because the letters at the end decide the output type and the connection. Remember that many Keyence sensors need a separately ordered cable or connector, and code readers need a cable, a power supply and often a mounting bracket. List those items, the cable length, and the communication interface your PLC uses.

Facts checked against Keyence's published company profile, October 2026.

FAQ

Questions about the Keyence FS-N14N Digital Fiber Amplifier Expansion

Answers from our engineering team on installation, compatibility and integration.

01Does the FS-N14N work alone?
It is an expansion unit, so it attaches to a main unit on the DIN rail and draws its power through the chain.
02How many outputs does it have?
It has two NPN open-collector outputs at 24 V, plus one external input for functions such as calibration.
03How does it count in the unit chain?
A two-output type is treated as two units in the 16-unit total, so plan the chain length accordingly.
04What is its response time range?
Response is selectable from 50 microseconds to 16 milliseconds, the same range as other FS-N amplifiers.
05What ambient temperature is allowed?
The base rating is minus 20 to plus 55 °C without freezing, reduced when more units are connected.