Brand: ifm
ifm LK1022 Capacitive Level Sensor, 264 mm, IO-Link
Description
ifm LK1022 Capacitive Level Sensor, 264 mm, IO-Link
The ifm LK1022 is a capacitive electronic level sensor with a 264 mm probe and an active measuring range of 195 mm, designed for the level in coolant, oil and water-based tanks. Four-digit LED display and a switching output give local indication of the level and allow it to feed a PLC. Within the active range, the set point can be moved in 5 mm steps between 25 and 200 mm.
The probe wetted part is polypropylene and the housing is stainless steel with an IP67 rating. Seven Star LLC supplies the LK1022 in Oman and the GCC as an independent supplier; quote LK1022 in your enquiry.
LK1022 technical specifications
The table lists the values published by the manufacturer for the LK1022. Where a parameter has several operating modes, the headline value is shown; the full parameter list is in the manufacturer documentation.
| Parameter | Specification |
|---|---|
| Manufacturer / part number | ifm electronic / LK1022 |
| Resolution [mm] | 5 |
| Dimensions [mm] | Ø 16 |
| Probe length L [mm] | 264 |
| Active range A [mm] | 195 |
| Media | hydrous coolants; oils; oil-based media; water; media similar to water |
| Medium temperature [°C] | 0 to 35 (with climatic tube E43100: 35 to 65 °C) |
| Operating voltage [V] | 18 to 30 DC |
| Current consumption [mA] | < 50 |
| Output signal | switching signal; IO-Link |
| Electrical design | PNP/NPN |
| Output function | normally open / normally closed (parameterisable) |
| Permanent current rating of switching output DC [mA] | 200 |
| Repeatability | ± 2 |
| Measuring error [% of the final value] | ± 5 |
| Communication interface | IO-Link |
| Ambient temperature [°C] | 0 to 60 |
| Protection | IP 67 |
| Weight [g] | 289.8 |
| Materials | stainless steel (304/1.4301); stainless steel (316L/1.4404); FKM; NBR; PBT; PC; PA; PP; TPV |
| Materials (wetted parts) | PP |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
| MTTF [years] | 265 |
How the LK1022 works
The LK1022 is a capacitive level probe: the measured medium changes the capacitance between the electrodes in the probe, and the electronics convert the covered length into a level value. The device shows the level on its LED display, and the switching output can be set to a level threshold in 5 mm steps within the active range. The probe is suited to water-based liquids, oils and coolants with a dielectric constant above the stated limit, but not to highly conductive, adhering or acidic media.
Where the LK1022 fits and related parts
Compared with the point level sensors LMT100, LMT121 and LMC510, the LK1022 reads level along a stretch, so it can show a trend and offer an adjustable switch point. Compared with the guided wave radar LR2750, it is limited to mild temperatures (0 to 70 degrees Celsius) and low tank pressure but is simpler and well suited to machine tool coolant tanks and similar systems.
Selection and ordering checklist for the LK1022
Work through the points below before you confirm the order, so that the LK1022 you receive is the one your machine or plant needs.
- Confirm the medium is water-based coolant, water or oil with a dielectric constant above 2
- Rule out extremely conductive or sticky media, granulates, bulk solids and acids
- Check the tank height against the 264 mm probe length and the 195 mm active range
- Check medium temperature (0 to 70 degrees Celsius, short-time 90) and pressure limit of 0.5 bar
- Choose the mounting accessory
The manufacturer lists this article under the type designation Electronic level sensor, LK0264B-B-00KQPKG/US. The article number LK1022 is the reference to quote when ordering, and the type designation is useful for technicians who compare the label on an installed unit.
Installation, commissioning and maintenance
Mount the probe vertically through a tank opening with the accessory fitting suited to the application, leaving the stated inactive zones at the top and bottom in mind when you choose the length. Keep the probe away from baffles and fill streams, and use the climate tube accessory when the medium is warmer than the base limit. At commissioning, fill to a known level, adjust the reference point and confirm the switching output at both thresholds. Over time, clean the probe if the coolant forms a film or sludge, and check that the cable is routed away from motor leads.
Mount the probe vertically with suitable accessories, and take the inactive zones (53 mm and 16 mm at the two ends) into account when planning the measuring window. If the coolant is warmer than the base limit, fit the climate tube accessory mentioned in the data. Check measuring error of ±5 % of final value in the planning, and clean the probe if the coolant leaves sludge.
Typical applications in Oman and the GCC
Machine tool coolant tanks, washing machines, and oil reservoirs in workshops are classical uses. In Oman and the GCC the LK1022 is used where operators want to read the coolant level at a glance and PLC alarms for low-level warnings, in fabrication shops, utilities rooms and water-based cooling circuits.
Level sensors in tanks exposed to Gulf summers must tolerate hot product, condensation on cold nozzles and long periods without attention. Plan a periodic proof test of the alarm point, and record the output state at known levels during commissioning.
LK1022 compared with related ifm types
The table places the LK1022 next to neighbouring types in the same application group, so you can see whether a sibling would suit the job better.
| Part number | Key characteristics | Note |
|---|---|---|
| LMT100 | Capacitive, hydrous media preset, G 1/2 | Related type |
| LMT121 | Capacitive, low-water media preset, G 1/2 | Related type |
| LMC510 | Capacitive, oil preset, 1/2 NPT, 2 outputs | Related type |
| LK1022 | Capacitive, 264 mm probe, 195 mm range | This page |
| LR2750 | Guided wave radar, 150-2000 mm, G 1 | Related type |
Information to send with an RFQ for the LK1022
To prepare an accurate offer for the LK1022, please include the following with your enquiry:
- Medium and its temperature profile
- Required probe length and tank depth
- Tank pressure and mounting fitting
- Switching output or IO-Link requirement
- Quantity and delivery location
Documents and quotation
No datasheet is attached to this page. Send us the part number LK1022 and we will confirm which documents are available, such as the datasheet and operating instructions, and for IO-Link devices the device description file.
Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC and is not affiliated with the manufacturer; the name ifm is used only to identify the product. Prices are not shown on the page, so send the part number, the quantity and the delivery location to receive a quotation.
Other Models in the Ifm Lk Range
Seven Star LLC supplies models from the Ifm Lk range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ifm LK1022 Capacitive Level Sensor, 264 mm, IO-Link | Level Instrumentation | You are viewing this model |
| ifm LR2750 Guided Wave Radar Level Sensor, G 1 Aseptoflex | Level Instrumentation | View details |
Reviews (0)
How would you rate this product? Cancel reply
About brand
ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.
Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.
ifm company profile
| Founded | 1969, Essen, Germany |
|---|---|
| Founders | Robert Buck and Gerd Marhofer |
| Headquarters | Essen, Germany |
| Ownership | Family-owned |
| Product families | Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters |
Milestones
- 1969: ifm is founded in Essen.
- 2001: The founders' sons take over management.
ifm sensors listed on this page
ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:
- O1D100: laser distance sensor for position and distance measurement
- PN7093: pressure sensor with local display
- NG5021: inductive proximity sensor with NAMUR output
Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.
ifm products we list
Ordering ifm sensors: what we need
Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.
Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.
Browse ifm products by category: Sensors & Transmitters, Pressure Instrumentation.
FAQ
Questions about the ifm LK1022 Capacitive Level Sensor, 264 mm, IO-Link
Answers from our engineering team on installation, compatibility and integration.
01What is the active range of the ifm LK1022?
The active range is 195 mm on a probe 264 mm long.
02Which media suit the LK1022?
Water, hydrous coolants, oils and oil-based media with a dielectric constant above 2.
03Which media are unsuitable for the LK1022?
Extremely conductive media, adhering media, granulates, bulk material and acids.
04What is the measuring error of the LK1022?
The measuring error is ±5 % of the final value and the resolution is 5 mm.
05What is the protection rating of the LK1022?
IP67. This is the value published by the manufacturer for the LK1022; confirm details before ordering.