Brand:

Fluke 718 100G Pressure Calibrator with Pump, 100 psi

Description

718 100G pressure calibrator with integrated pump to 100 psi

The Fluke 718 100G is a handheld pneumatic pressure calibrator with a built-in hand pump, an internal sensor covering -12 psi to 100 psi and a milliamp measurement function accurate to 0.015 %. It lets one technician calibrate a pressure transmitter, gauge or switch with a single instrument, without carrying a separate pump and reference gauge. Seven Star LLC supplies the 718 100G in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The 718 family has four models: 718 1G, 718 30G, 718 100G and 718 300G. The number is the full-scale range in psi and G denotes gauge pressure.

Element Meaning Detail
718 Model family Integrated pump calibrator
100 Full-scale pressure in psi -12 to 100 psi (-850 mbar to 6.895 bar)
G Gauge pressure Relative to atmospheric pressure

718 100G technical specifications

Parameter Specification
Manufacturer / part number Fluke / 718 100G
Pressure range -12 psi to 100 psi (-85 kPa to 689.48 kPa)
Resolution 0.01 psi, 0.1 mbar
Accuracy 0.05 %
Over pressure 2 x full scale (datasheet range table)
Functions Zero, min, max, hold, damp; error percentage calculation; switch test
Media Non-corrosive gases only
External modules 29 Fluke 700Pxx modules, 0 to 1 in H2O up to 10,000 psi, accuracy to 0.025 % of full span
mA measure 0 to 24 mA, 0.001 mA resolution, 0.015 % + 1 count
Loop power 24 V dc, ±10 %; drives 20 mA into 1000 Ω with battery above 6.8 V
Display LCD, five digits, pressure and current simultaneously
Power Two 9 V alkaline batteries
Battery life 4 to 20 hours typical, depending on functions
Size / weight (with holster) 216 x 94 x 66 mm / 992 g
Operating / non-operating temperature -10 °C to 55 °C / -40 °C to 60 °C
Warranty Three years; one year on the pump

How the protected pump of the 718 100G works

Most manual pumps are damaged when a trace of process liquid enters from the device under test. The pump in the 718 100G uses two check valves that let air pass in both directions but block fluids. If liquid does get through, two retention caps on the underside give access to the valve bodies, which can be cleaned with isopropyl alcohol and cotton swabs and re-seated in the field without disassembling the unit. After cleaning, pressurise to at least half of the rated pressure and release several times to seat the o-rings.

The error percentage function shows how far a reading lies from the expected value as a percentage of span, helping the technician decide pass or fail on the spot. Switch test mode captures the pressure at which a switch operates.

Where the 718 100G fits in the Fluke pressure range

The 718 range is for dry gas calibrations and field work with transmitters and switches, with the pump built in. The 717 range is a related set of calibrators without a pump, and the 719Pro uses an electric pump for hands-free pressurising. If you need liquids, use a 700Pxx module with a hydraulic pump or a dead-weight tester. A 71X trap kit is available to protect the pump on at-risk applications.

Model Range Resolution Over pressure
718 1G -1 to 1 psi 0.0001 psi 5 x FS
718 30G -12 to 30 psi 0.001 psi 2 x FS
718 100G -12 to 100 psi 0.01 psi 2 x FS
718 300G -12 to 300 psi 0.01 psi 375 psi

The datasheet recommends referring to the separate application note on pressure calibration with the 718 for more detail on procedures, and it lists supported units including psi, inches and centimetres of water at 4 °C and 20 °C, bar, mbar, kPa, inches and millimetres of mercury and kg/cm2. A technician who works to metric procedures can therefore stay in bar or kPa while a colleague working to imperial procedures reads psi from the same instrument.

Selecting the 718 100G

  • Confirm that the maximum pressure of your devices is not above 100 psi; the 300G exists for higher pressures.
  • Confirm that the process media is a non-corrosive gas, or use a trap.
  • Check whether the connection is NPT or BSP and order the hose kit adapters accordingly.
  • Decide if a 700Pxx module is needed for other ranges.
  • Plan spare 9 V batteries, since the unit takes two.

Use and maintenance of the 718 100G

Zero before each calibration with the port open to atmosphere. Use the supplied hoses and quick-connect fittings and tighten fittings by hand. After any liquid contact, clean the pump valves as in the datasheet procedure. Inspect springs: they should be about 8.6 mm long in the relaxed state, and shorter springs may not seat the o-ring properly. Replace worn o-rings. Store the calibrator in its holster away from heat.

Typical applications of the 718 100G in Oman and the GCC

Instrument crews use the 718 100G for compressed air systems, instrument air supply headers, boiler and burner management transmitters, and pressure switches on compressors and pumps in oil and gas, power, water and desalination facilities. It is light enough to carry up platforms and compact enough for a toolbox. In hot climates, keep it out of direct sun.

Information to send with an RFQ for the 718 100G

  • Part number 718 100G (or 718 1G, 30G, 300G)
  • Quantity and hose kits, modules or traps
  • Pressure ranges and media
  • Delivery location and time frame
  • Calibration certificate requirement

Storage, handling and spares for the Fluke 718 100G

Keep the Fluke 718 100G in its carrying case when it is not in use, and store it in a clean, dry place. Remove or charge the batteries as recommended in the user manual before long storage. Field teams in Oman and the GCC should avoid leaving the instrument in a vehicle in the sun, as high cabin temperatures can exceed the storage range and shorten battery life.

  • Check the instrument, cables, hoses or lenses for damage before each job.
  • Clean the unit with a soft, slightly damp cloth only; do not use solvents unless the manual allows them.
  • Plan a calibration interval that matches your quality system, and keep the calibration certificate with the asset record.
  • Order wear parts and accessories, such as batteries, test leads, hoses or adapters, together with the instrument.

For calibration and test work, it helps to state in your RFQ whether you need an accredited calibration certificate with the Fluke 718 100G, so the right documents can be confirmed with the quotation.

Documents and quotation

A datasheet covering the 718 family is attached on this page.

Send us the part number 718 100G and the quantity and we will confirm availability and a quotation.

Other Models in the Fluke 717 718 Pressure Range

Seven Star LLC supplies models from the Fluke 717 718 Pressure range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Fluke 717 100G Pressure Calibrator, 100 psiProcess, Pressure & Temperature CalibratorsView details
Fluke 718 100G Pressure Calibrator with Pump, 100 psiProcess, Pressure & Temperature CalibratorsYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 718 100G Pressure Calibrator with Pump, 100

Answers from our engineering team on installation, compatibility and integration.

01What range does the Fluke 718 100G cover?
The 718 100G covers -12 psi to 100 psi, equal to -850 mbar to 6.895 bar, with 0.01 psi resolution and an accuracy of 0.05 %.
02Does the Fluke 718 100G have a built-in pump?
Yes. It has an integrated hand pump with check valves that protect against fluids, and cleanout access that allows servicing in the field without disassembly.
03How accurate is mA measurement on the Fluke 718 100G?
The mA measurement range is 0 to 24 mA with 0.001 mA resolution and an accuracy of 0.015 % plus 1 count. It also supplies 24 V loop power.
04Can the Fluke 718 100G use external pressure modules?
Yes. It works with 29 Fluke 700Pxx pressure modules covering 0 to 1 in H2O up to 10,000 psi, with accuracy to 0.025 % of full span per module.
05What batteries are needed for the Fluke 718 100G?
The 718 uses two 9 V alkaline batteries, giving 4 to 20 hours of typical use depending on functions. The unit is supplied with a protective holster.