Brand: Schneider Electric
Schneider Electric RXZE2S108M RXZ Socket 2 C/O Separate
Description
RXZE2S108M: RXZ socket for RXM relays, 2 C/O, separate contacts
The RXZE2S108M is a Schneider Electric Harmony RXZ socket for plug-in relays. Its datasheet lists 2 C/O contacts, a separate contact arrangement, a conventional free-air thermal current of 12 A, a width of 27 mm and screw connectors. The relays it is listed for are: RXM with 2 C/O contact; REXL with 2 C/O contact. Seven Star LLC supplies the RXZE2S108M in Oman and the GCC as an independent supplier based in Muscat.
Sockets are bought separately from relays, so the RXZE2S108M is typically ordered together with a matching RXM relay of the contact count listed above, or with a relay already in use that matches the listed compatibility.
Installing and maintaining the RXZE2S108M
Mount the this part first, wire it with the panel isolated, tighten the screws to the listed torque and then insert the relay. After commissioning, retighten terminal screws once the first thermal cycles have passed, since copper creeps and screw terminals can loosen on loads that heat and cool.
The socket outlives many relay replacements, so keep it clean and check for discoloured terminals, a sign of a loose connection or an overloaded contact, when changing relays.
Relays that fit the RXZE2S108M
The datasheet compatibility entries are: RXM with 2 C/O contact; REXL with 2 C/O contact. This socket is specifically listed for 2 C/O relays, so it is not a substitute for a 4 C/O base.
Technical specifications of the RXZE2S108M
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / RXZE2S108M |
| Range | Harmony Electromechanical Relays, Harmony Timer Relays |
| Product type | Socket |
| Device short name | RXZ |
| Compatible relays | RXM with 2 C/O contact; REXL with 2 C/O contact |
| Contacts | 2 C/O |
| Contact terminal arrangement | Separate |
| Conventional free-air thermal current [Ith] | 12 A |
| Rated operational voltage [Ue] | < 250 V conforming to IEC < 300 V conforming to UL |
| Rated impulse withstand [Uimp] | 4 kV |
| Overvoltage category | III |
| Pollution degree | 3 |
| Terminal type | Screw connectors |
| Tightening torque | < 1 N.m for M3 screw(s) |
| Wire stripping length | 8 mm |
| Fixing mode | By screw (panel) or clip-on, 35 mm symmetrical DIN rail |
| Width | 27 mm |
| Net weight | 0.048 kg |
| Degree of protection | IP20 conforming to IEC 60529 |
| Dielectric strength | 2500 V |
| Standards | IEC 61984, Product certifications CSA, Lloyd’s, UL |
| Operating temperature | -40–55 °C |
| Storage temperature | -40–55 °C operation |
| Sold in indivisible quantities of | 10 |
| Warranty | 18 months |
Selection checklist for the RXZE2S108M
- Relay: confirm the relay reference is in the compatibility list (RXM with 2 C/O contact; REXL with 2 C/O contact).
- Contacts: 2 C/O.
- Current: up to 12 A thermal, with the lowest rating in the circuit governing.
- Terminals: screw connectors.
- Width: 27 mm on the rail.
- Pack: sold in indivisible quantities of 10.
Where the RXZE2S108M is used in Oman and the GCC
In the region, sockets of this type are mostly found in control panels for pumps and compressors, switchgear auxiliary and trip circuits and desalination and water treatment skids. Plug-in relays on sockets allow quick replacement during shutdowns, which is valuable where heat, dust and humidity shorten relay life.
Contact arrangement of the RXZE2S108M
The datasheet lists a separate contact terminal arrangement on this socket. The other RXZ sockets in this group include mixed versions, so the arrangement is one of the points that differ between references. The wiring diagram on the datasheet shows the numbering, which should be followed when wiring.
It is rated for 2 C/O contacts with a thermal current of 12 A, so it handles the relay contact set listed under compatibility and not other pole counts. The datasheet states pollution degree 3, overvoltage category III and a 4 kV impulse withstand, which describe the environment and supply category the socket is designed for.
The RXZE2S108M among RXZ sockets
The RXZ range includes mixed and separate-contact versions, different widths and screw clamp or screw connector terminals. The table shows the references covered in this group.
| Part number | Contacts | Arrangement | Thermal current | Width | Terminals |
|---|---|---|---|---|---|
| RXZE1M2C | 2 C/O | Mixed | 7 A | 22.5 mm | Screw clamp |
| RXZE2M114 | 4 C/O | Mixed | 10 A | 30 mm | Screw clamp |
| RXZE2M114M | 4 C/O | Mixed | 10 A | 27 mm | Screw connectors |
| RXZE2S108M (this page) | 2 C/O | Separate | 12 A | 27 mm | Screw connectors |
| RXZE2S111M | 3 C/O | Separate | 10 A | 27 mm | Screw connectors |
| RXZE2S114M | 4 C/O | Separate | 10 A | 27 mm | Screw connectors |
Information to send with an RFQ for the RXZE2S108M
- Exact reference this part and the quantity.
- Relay reference that will sit in the socket.
- Required contacts, 2, 3 or 4 C/O.
- Preferred terminal style.
- Matching relays or retaining clamps needed in the same order.
- Delivery location and timeline.
For critical duties, keep one tested spare of every relay and base type on site, and label the shelf location in the maintenance system so that outage crews can find it quickly.
If the panel is later modified, update the drawings with the exact references fitted, because mismatches between drawings and hardware cost more time than almost any other documentation fault.
When a project is tendered with alternates, state the exact accepted references in the bill of materials, since mixed substitutions between similar-looking relays and bases are a common cause of rework at site.
Store spares in their original packaging in a dry cabinet, away from direct sun and corrosive atmospheres, so that terminals and pins stay clean until they are needed.
Where several panels use the same reference, standardising on one part number simplifies the spares list and reduces the risk of fitting the wrong version during a shutdown.
Check delivery packaging and the reference printed on the part when it arrives, so that any difference from the order is found before installation work starts.
Before ordering, check that the panel layout leaves room for heat to escape, since closed enclosures in hot rooms run closer to component limits than the rated ambient suggests.
Record the installed reference and coil or relay type on the panel schedule, because later fault investigation and replacement depend on knowing exactly what was fitted.
Keep a spare of this reference for sites that run continuously, since a like-for-like replacement keeps the original design intact after a failure.
Documents and quotation
The Schneider Electric datasheet for the this part is attached on this page and holds the full specification summarised above. It is dated 8 Nov 2026 as printed on the manufacturer’s document.
Send us the reference RXZE2S108M, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.
Other Models in the Schneider Harmony Rxz Socket Range
Seven Star LLC supplies models from the Schneider Harmony Rxz Socket range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric RXZE1M2C RXZ Socket 2 C/O Mixed | Contactors & Overload Relays | View details |
| Schneider Electric RXZE2M114 RXZ Socket 4 C/O Mixed | Contactors & Overload Relays | View details |
| Schneider Electric RXZE2M114M RXZ Socket 4 C/O Mixed | Contactors & Overload Relays | View details |
| Schneider Electric RXZE2S108M RXZ Socket 2 C/O Separate | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric RXZE2S108M Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric RXZE2S108M RXZ Socket 2 C/O
Answers from our engineering team on installation, compatibility and integration.
01Which relays fit the RXZE2S108M?
The datasheet compatibility list reads: RXM with 2 C/O contact; REXL with 2 C/O contact.
02What current is the RXZE2S108M rated for?
A conventional free-air thermal current of 12 A, with rated operational voltage < 250 V conforming to IEC < 300 V conforming to UL. The datasheet gives a rated impulse withstand of 4 kV.
03What terminals does the RXZE2S108M have?
Screw connector terminals, with a separate contact terminal arrangement and a tightening torque of < 1 N.m for M3 screw(s).
04How is the RXZE2S108M mounted?
By screw on a panel or clip-on on a 35 mm symmetrical DIN rail. It is 27 mm wide.
05What temperature range applies to the RXZE2S108M?
Operation is listed from -40 to 55 degrees C, with a dielectric strength of 2500 V.


















Reviews
There are no reviews yet.